EXFO FTB-200 FTB-8510B kit with accessories

EXFO FTB-200 FTB-8510B Gigabit Ethernet Tester

Noyes M700 kit with accessories

AFL Noyes M700 SM Fiber OTDR

Anritsu MT9090A MU909014B SM Fiber OTDR

$3,295.00
Availability: Out of stock
SKU
6C136

Condition: Refurbished / Calibrated

Warranty: 90 Dday Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

Anritsu MT9090A Mainframe

Last Mile Testing Redefined!
MT9090A/MU909011A OVERVIEW

Until now, the right tool just didn’t exist for cost effectively testing short fibers. Handheld OTDRs and Fault Locators lacked the resolution and in such short spans while mini-OTDRs were too large, too expensive and too complicated. The new MT9090A from Anritsu finally addresses this need by providing all of the features and performance required for installation and maintenance of short fibers in a compact, modular test set. The MT9090A represents an unmatched level of value and ease of use, while not compromising performance. Data sampling of five centimeters and deadzones of less than one meter, ensure accurate and complete fiber evaluation while a simple testing sequence requires only one key press to initiate – allowing anyone to make error-free measurements. The MT9090A represents a new era in drop cable and premise testing. Its ease of use, low price, high-resolution and size make this the perfect product for “last mile” and intra-building testing.

Key Features
  • Unique, purpose-built solution for short fiber applications such as FTTx drop, MDU riser and CO cables
  • Exclusive, integrated launch fiber provides accurate initial connector measurement without external devices
  • High resolution, widescreen color display that is easy to read indoors or out
  • Fixed parameters simplify operation and ensure proper set-up – just press “START”
  • High resolution and extremely short deadzones ensure thorough short fiber evaluation
  • Rugged, sealed design provides years of service in the most challenging environments
  • Modular platform ensures maximum return on investment
  • Compact and lightweight design for maximum portability in the field
  • Complete FTTx maintenance tool including optical power meter and visible source “red light”
  • Unique 780 nm wavelength for in-service maintenance of PONs without filters
  • High performance without a high price

Purpose-Built for Short Fiber Applications
Realizing that short fiber premise applications such as FTTx drop cables, intra-building riser cables and cell towers have different testing requirements, Anritsu designed the MT9090A from the ground up. It features 5 cm resolution for accurate mapping of events, deadzones of less than 1 meter (3 feet) and a built-in 10 m (30 ft) launch fiber to ensure everything is evaluated.

Quick Startup
The MT9090A is ready for measurement in about 15 seconds so productive work can start immediately.

Long Battery Life
Since AC power is not always available where you need it, especially at fiber pedestals, the MT9090A typically provides 3.5 hours of testing on a single charge. This coupled with an optional car cigarette lighter cord guarantees the MT9090A is ready when you are.

Portable
With its lightweight design and user friendly dimensions, the MT9090A is perfect for the outside plant environment and can easily be managed with one hand. The standard softcase with shoulder strap further increases portability when traveling from the truck to the testing site.

Rugged
With no fans or vents to allow dust and moisture to enter the unit, the MT9090A was designed for the challenging outside plant environment.

Video Inspection Probe Support
When equipped with the optional connector video inspection probe (VIP), the MU909011A becomes a powerful tool for evaluating connector cleanliness and quality. Connector end faces can be safely viewed and images stored to document all aspects of your network.

4.3 inch Wide Screen Display for Easy Viewing
The high resolution, full color, 4.3 inch wide screen display is the perfect format for viewing OTDR results. It also provides excellent readability both indoors and outdoors.

<1m Dead Zone for Short Fiber Analysis
With less than 1m dead zones, the MT9090A is perfect for evaluating central office, FTTX and intra building cables.

No Experience Required
With the MT9090A, the expertise is built in. With an automated testing sequence, fixed parameters and PASS/FAIL classification, anyone can certify and troubleshoot drop cables or premise networks.

Installation and Maintenance Simplified
Since the MT9090A is purpose built for testing short fiber spans, its hardware and user interface are optimized for simplicity. A customizable testing sequence automates testing and guides novice users.

Installation Simplified
The MU909011A fault locator module provides easy and accurate verification of drop cable installation. The user simply connects the fiber and presses “START” for true one-button testing - all settings are fixed to ensure accurate and consistent results for any skill level. Upon completion, the length, total loss and PASS/FAIL status are displayed within seconds. A full event table of all characteristics is also shown providing additional information on the fiber under test.

A Unique Approach to In-Service Maintenance
Since multiple users share the common feed fiber, FTTx maintenance becomes difficult when only one or two users are down. Traditionally, 1625 nm or 1650 nm wavelengths were used to test active fibers however these wavelengths typically need costly WDM couplers and filters in the network. As a unique approach to this, Anritsu also offers a 780 nm Fault Locator module that can be used to troubleshoot inservice FTTx networks without costly filters and without disruption to other customers. This offers a clear advantage over PON specific power meters that only verify signal presence but still rely on an additional OTDR or fault locator to locate the cause. With the MT9090A, one box does it all !


Specifications:
MU909014B/B1-056/066
Center Wavelength 1310/1550±20 nm
Dynamic Range PW = 20 µsec 32.5 dB/31 dB
PW = 500 nsec 24.5 dB/23 dB
Fiber Type 10 µm/125 µm SMF (ITU-T G.652)
Optical Connector UPC (∗05x)/APC (∗06x) are selectable, FC/SC/LC/ST/DIN adapters are changeable
Distance Range 0.5, 1, 2.5, 5, 10, 25, 50, 75, 125, 250 km
Pulse Width 5, 10, 20, 50, 100, 200, 500 ns, 1, 2, 5, 10, 20 µs
Dead Zone Fresnel: <1 m, Backscatter: <5 m
Number of Sampling Points <125,001 pts (Course: <6,251 pts, Medium: <25,001 pts, Fine: <125,001 pts)
Sampling Resolution 5 cm (min.)
Linearity Which ever is greater ±0.05 dB/dB or ±0.1 dB
Return Loss Measurement Accuracy ±2 dB
Distance Measurement Accuracy ±1 m ±3 × Measurement distance × 10–5 ± Marker resolution (excluding IOR uncertainty)
Data Storage Internal memory: 40 MB (<1,000 traces)
External (USB Memory): 1 GB (<30,000 traces)
IOR Setting 1.3000 to 1.7000 (0.0001 steps)
Units km, m, kft, ft, mi
Testing Modes Full automatic, Manual, Real time, Optical Power Meter, Visible Fault Locator (Option), Video Inspection Prove (Option)
Fiber Event Analysis Automatic, Displayed in table format based on user defined PASS/FAIL thresholds
Loss Measurement Modes 2 point loss, Splice loss, dB/km Loss LSA, ORL, Event
OTDR Trace Format Telcordia universal (.SOR) issue 2 (SR-4731)
Other Functions Integrated launch fiber: 10 m (30ft)
Connection check: Automatic check of OTDR to FUT connection quality
Live fiber detect (Option 056/066 only): Verifies presence of communication light in fiber
Real time sweep: <1 sec (typ.)
Optical Power Meter Wavelength: 1310/1490/1550/1625/1650 nm
Measurement range: –50 to –5 dBm
Accuracy: ±0.5 dB (at –20 dBm, CW, +25°C, 1310/1490/1550 nm)
Maximum input: +10 dBm
Language User Selectable (English, Simplified Chinese, Traditional Chinese, Korean, Japanese, French, German, Italian, Spanish, Polish, Portuguese, Danish, Swedish, Spanish (Latin America) and Russian)
Power Supply 9 V (dc), 100 V (ac) to 240 V (ac), Allowable Input voltage range: 90 V (ac) to 264 V (ac), 50 Hz/60 Hz
Battery NiMH (Standard battery), NiMH (AA Type), Alkaline Dry Battery (AA Type)
Operating time (Standard battery): 8 hours (typ.
Recharging time: <4 hours (typ.)
Environment Operating temperature and humidity: –5 to +40°C, <80 % (no condensation)
Storage temperature and humidity: –20 to +60°C, <80 %
Vibration: MIL-T-28800E Class 3, Dust and Drip proof: IP51
EMC EN61326-1, EN61000-3-2
Laser Safety IEC Pub 60825-1: 2007 Class 1, IEC Pub 60825-1: 2007 Class 3R (VLD Option), 21CFR1040.10

 
Anritsu MT9090A Mainframe w/
Anritsu MU909014B SM OTDR Module w/ Power Meter

Dynamic Range:
1310 / 1550 nm : 32.5 / 31 dB

Power Meter:
- 1310nm
- 1490nm
- 1550nm
- 1625nm
- 1650nm

Includes Carrying Case & Accessories As Listed
 
MT9090A MU909014B MU 909014B MU-909014B MT 9090A MT-9090A

Anritsu MT9090A MU909014B MT-9090A MU-909014B OTDR Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 27555
  • Anritsu MT9090A Mainframe (BC# 27555)
  • Anritsu MU909014B SM OTDR Module
    • SM OTDR Source:
      • 1310nm
      • 1550nm
    • SC Connector For OTDR Source
    • Power Meter:
      • 1310nm
      • 1490nm
      • 1550nm
      • 1625nm
      • 1650nm
  • (2) SM SC-SC Fiber Cables
  • (4) Fiber Wipes
  • Rubber Cover For Unit
  • AC Adapter/Charger
  • USB PC Interface Cable
  • User Manual On CD-ROM