Acterna MTS-5100E 5026DR kit with accessories

Acterna MTS-5100e 5026DR SM Fiber OTDR

Fluke Networks 682 kit with accessories

Fluke Networks 682 LANMeter Cat5e Network Analyzer

CXR Telecom Halcyon 704A-410 Transmission Set

$1,095.00
Availability: Out of stock
SKU
CX03

Condition: Refurbished / Calibrated

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

 704A-400 Basic hand-held transmission set with 400 KHz range and Network Access/Signalling Test Functions with loop start, ground start, and DID test interfaces

CXR Halcyon's 704A-400 Series are hand-held transmission and signalling wideband test sets optimized for installation and maintenance of analog voice and data services including Class Services and circuits utilzing DIDSignaling (E911).  

When equipped with 400 kHz Option,  it is ideally  suit- ed for ADSL, HDSL, ISDN and DDS Facility Testing. Designed with state-of-the-art technology and engineered for ease of operation, the 704A-400 Series provides users with single-button test execution allowing quick circuit diag- nosis and repair without extensive training.  The internal NiCAD battery pack provides up to 4-hours of continuous operation.  The hand-held 704A-400 Series  is the complete test solution  for installation and  maintenance of analog voice and data circuits.

Features:
  • Rugged, Lightweight & Hand-Held
  • RJ 11 Modular Jack
  • Dual Mini-Phone Jacks (Bantam)
  • 2-Wire and 4-Wire Interface
  • 135, 600, 900, 1200 Ohm and Bridged
  • Measure Line Voltages and Polarity
  • Monitoring RINGING Voltage
  • Generate and Measure:
    • - Frequency and Level
    • - 3-Tone Slope & 2713Hz Lpbk
    • - Peak to Average Ratio (PAR)
  • Noise Measurements:
    • - Filtered and Notched
    • - Signal to Noise
    • - Impulse Noise
  • Power Influence:
    • - Stress Noise
    • - Noise to Ground
  • Filter Selections:
    • - C-Message, 3 KHz Flat
    • - Program-Weighted
    • - 15 KHz and 50 KHz


Specifications:

 
 
General
Physical 9.5?L x 6.33?W x 1.4?H, 2.2 pounds.
Operating Environment:  0 to 50 ° C, 0 to 95% R.H. (Non-Condensing).
Power 5W at 115VAC, 60 Hz nom. from 9VDC external power
supply.
Battery 4 hours continuous operation from internal 7.2 VDC NiCad Pack.
Charge time: 14 hours.
2W/4W Interface:   RJ 11C or Dual Bantam (210) jacks.
Impedance 135/600/900, 1200 Ohms Terminated, >30K 2W- Bridged.
Longitudinal Balance:  >60dB from 200 to 4 KHz.
Audio Internal speaker with volume control.
Display 4-line by 20-character LCD and status LEDs.
Line Hold: Electronic Internal current limited to 24mA when Off Hook.
Dial Mode: 16 character DTMF generator.
12 character MF generator, 10 digit dial pulse gen.
Generator
Frequency 50 Hz to 25 KHz in 1 Hz steps
(Optional) 50 Hz to 400 KHz in 1 Hz steps
Accuracy + 0.5 Hz
Level:    +7 to -40 dBm in 0.1 dB steps
Accuracy:    +0.2 dB 50 Hz - 200 Hz
+0.1 dB 200 Hz - 15 KHz
+0.2 dB 15 KHz - 400 KHz
3-Tone Slope:  404, 1004, 2804 ± .5 Hz. Level adjustable in 4 steps of
0, -10, -13, and -16 dBm ± 0.2dB.
2713Hz Loopback: Generated at ± 0.5Hz.  Level adjustable as in 3 tone slope
P/AR:   Continuous ANSI 743-1984 P/AR signal at -6dBm
Return Loss:   Continuous filtered noise signal at -6 ±1dBm for ERL,
SRL-L and SRL-H.
DTMF Generator:  -7±0.2dBm, 1.5dB twist, frequency accurate to ±.5 Hz.
75 mS on 75 mS off.
Receiver
Level +7 dBm to -70dBm, 0.1 dBm resolution; 135/600/900 ohm 4-Wire mode:
0 dB to -60 dBm; 0.1 dBm re
Accuracy:   1200 ohm - 2-Wire mode
+0.2 dB - 50 Hz to 200 Hz
+0.1 dB 200 Hz to 15 KHz
+0.2 dB 15 KHz to 400 KHz (Opt.)
Frequency 50 Hz to 25 KHz with 1 Hz res. (Optional 50 Hz to 400 KHz)
Accuracy +0.1 dB 50 Hz to 200 Hz
+0.1 dB 200 Hz to 15 KHz
+0.2 dB 15 KHz to 400 KHz (Opt.)
Noise 15 to 95 dBrn with 1 dB resolution and ±1 dB accuracy from 20
to 90 dBrn.
Notched Noise: 1010Hz notch, with a minimum of 50 dB attenuation in the band of
995 to 1025 Hz.
Signal to Noise Ratio:  Holding tone (1004Hz) must be in range of +6 to -45 dB; measured S/N
ratio range from 10 to 55 dB with 1 dB resolution and ±2 dB accuracy.
3-Level Impulse Noise:  Threshold can be set from 30 to 90dBrn; 3 level differ- ence fixed at 4 dB with a measurement accuracy of +1 dB.
Blanking interval fixed at 125mSec; with 3 independent counters.
P/AR: Measured from 30 to 180 units with a 1 unit resolution. Accuracy is ±2 units from 40 to 120. Received P/AR
signal must be greater than -45 dBm.
Return Loss: Three bands: ERL,SRL LO, SRL HI range of 0 to -30dB with .1 dB resolution and ±1 dB accuracy.
Line Voltage Measurement:  2 to 85VDC; 0.1 Volt resolution and ±1 Volt accuracy.
Line Current Measurement 5 to 35mA; 0.1 mA resolution and ±1 mA accuracy.



For full CXR Telecom Halcyon 704A-410 specifications, please click here: CXR telecom Halcyon 704A-410

CXR Telecom Halcyon 704A-400 Basic Handheld Transmission Set w/ Option B: 1.5MHz KHz Frequency Band for ADSL, HDSL, & ISDN Facility Testing

The 704A-400 has 400 KHz range

The hand-held 704A-400 Series is the complete test solution for installation and  maintenance of analog voice and data circuits.

Includes Carrying Case & Accessories As Listed

704A410 704A 410

CXR Telecom Halcyon 704A-410 Transmission Test Set Halcyon 704A410 Transmission Test Set Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 25262

  • CXR Telecom Halcyon 704A-410 Basic Handheld Transmission Set w/ Option: (BC# 25262)
    • Option B: 1.5MHz KHz Frequency Band for ADSL, HDSL, & ISDN Facility Testing
  • (2) Bantam Cables
  • A Adapter/Charger
  • User Manual On CD-ROM
  • Carrying Case (G)