EXFO VCS-20A kit with accessories

EXFO VCS-20A-02BL Multifunction Fiber Optic Talk Set VCS20A VCS 20A VCS20A02BL

EXFO FPM-300 FLS-300 kit with accessories

EXFO FPM-302X FLS-300-12D-23BL SM MM Fiber Loss Test Set (FPM-300 FLS-300)

EXFO PPM-350B PON SM Power Meter 1310 1490 1550 (PPM-352B-EA-VZ1)

$745.00
Availability: In stock
SKU
4F17

Condition: Refurbished

Warranty: 1 YEAR WARRANTY

  • Pass/warning/fail indicators (10 threshold sets) for easy assessment of power valuesâ??anywhere on the network
  • Simultaneous measurement and display of all PON signalsâ??voice, data and video
  • Filtered measurements, providing distinct power values for each signal (1310 nm, 1490 nm and 1550 nm)
  • The most easy-to-use instrument of its kind: simply connect the fiber and read the results
  • Extended-range option for testing at the central office (CO) and before the splitter
  • Go-anywhere versatility: enables quick, accurate testing all across the network

The industryâ??s first PON-specific power meter, the PPM-350B is the flagship of EXFOâ??s line of test instruments specifically intended for FTTH and FTTP systems.

 Service Activation Testing

Optimizing network reliability requires that all PON signals be measured all the way through service activation to ensure they meet established standards. The PPM-350B offers the features to address this need:

  • Pass-through connection for ONT signal measurement and simultaneous measurement of all PON signals
  • Filtered detectors for individual measurement of each wavelength
  • Upstream burst detection at 1310 nm

 Troubleshooting Testing

Throughout the maintenance phase, various transmission problemsâ??fiber cuts, damaged/dirty connectors, macrobendings, optical transmitter failure, etc.â??may ultimately cause signal loss or degradation. Benefit from the PPM-350Bâ??s troubleshooting functionalities:

  • Quick, on-site test and measurement of PON signals, anywhere on the network
  • Fault identification and isolation

Correctly measuring PON signals can be a challenging task: not only can a single fiber carry up to three signals, but the upstream signal coming from the ONT operates in burst mode, which means that it is only active during its â??allowedâ?? timeslot. This is true whether the network is based on the BPON, EPON or GPON technology. Moreover, the timeslot is shorter in higher-speed networks such as EPON and GPON. Designed with this in mind, the PPM-350B PON Power Meter delivers accurate results for burst signals.

 Groundbreaking Technologyâ??Two-Port Pass-Through
The PPM-352B two-port model acts as a pass-through device, which means that it is connected between the OLT and the ONT. A small percentage of the signal is extracted for use by the power meter's detectors.

This approach enables all wavelengths to be used simultaneously. Also, since the PON equipment can keep functioning normally, the ONT continues to operate (to respond to the OLT), and therefore to transmit and have its laser on.

 Up to 10 User-Definable Threshold Sets
Depending on the location of the test and the type of equipment used, different threshold values can be required. The PPM-350B enables you to select from up to 10 threshold setsâ??each set consisting of three wavelengths (1310, 1490 and 1550 nm) having their own pass, warning and fail thresholds. These values can be configured via the HHDT PC-based software.

Specifications:

Power measurement range â?? pass zone  1310 nm  5.5 to â??15 
for continuous data stream (dBm)  1490 nm  1 to -33 
1550 nm  15 to -36 
Burst mode measurement capability:  Splitter to ONT 
Burst mode measurement range b (dBm)  1310 nm  5.5 to -15 
Pass through insertion loss b (dB)  1.5
Spectral passband (nm)  1310 nm  1260 to 1360 
1490 nm  1480 to 1500 
1550 nm  1539 to 1565 
Power uncertainty at calibrated  0.5
wavelengths b, d (dB) 
Refresh rate of display (Hz)  2.5
Calibrated wavelengths (nm)  1310, 1490, 1550  1310, 1490, 1550 
Threshold sets  10 configurable threshold sets
 with threshold naming 
Autonomy b (hours)  > 30 
Number of ports  1



For full EXFO PPM-352B-EA-VZ1 product specifications, please click here: EXFO PPM-352B-EA-VZ1

EXFO PPM-350B Singlemode PON Power Meter For FTTx Activation

Power Meter:
- 1310nm
- 1490nm
- 1550nm

Upstream EPON and GPON ONT signal for up to 1.25 Gb/s, as per ITU 984 and IEEE 802.3ah

Includes Carrying Case & Accessories As Listed

PPM-352B PPM-352 PPM352 PPM352B PPM350 PPM350B PPM 350 350B 352

EXFO PPM-350B PPM350B SM Fiber Power Meter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 42239-L/T*

  • EXFO PPM-352B-EA-VZ1 PON Power Meter (BC# 42239-L/T*)
    • Power Meter:
      • 1310nm
      • 1490nm
      • 1550nm
  • (2) SC Connectors
  • (2) SM SC-SC APC Fiber Cables
  • AC Adapter/Charger
  • RS232 PC Interface Cable
  • Strap For Unit
  • Hard Copy User Manual
  • Carrying Case (G)
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!