Fluke 190-504 Scopemeter
190 ScopeMeter Portable Oscilloscopes—the first high-performance scopes built for harsh industrial environments

Introducing the first high-performance portable oscilloscopes with 2 or 4 independently insulated input channels, an IP51 dust- and dripwater proof rating and a CAT III 1000 V/CAT IV 600 V safety rating. Choose from 500 MHz, 200 MHz, 100 MHz or 60 MHz bandwidth models. Now plant maintenance engineers can take a 2- or 4-channel scope into the harsh world of industrial electronics.

190—a new generation of Fluke ScopeMeter Oscilloscopes
The 190 include these capabilities:

  • Up to four independent floating isolated inputs, up to 1000 V
  • Up to 5 GS/s real time sampling (depending on model and channels used)
  • Deep memory: 10,000 points per trace waveform capture (scope mode)
  • CAT III 1000 V/CAT IV 600 V safety rated instrument for industrial environments
  • Up to seven hours of battery operation using BP291
  • Isolated USB host port for direct data storage to a USB memory device; USB device port for easy PC communication
  • Easy access battery door for quick battery swaps in the field
  • Compact and only 2.2 kg (4.8 lb)
  • Security slot: lock down oscilloscope with Kensington® lock while unattended
  • IP51 rating, dust- and drip-proof
  • Connect-and-View™ triggering for intelligent, automatic triggering on fast, slow and even complex signals
  • Frequency spectrum using FFT-analysis
  • Automatic capture and REPLAY of 100 screens
  • ScopeRecord™ Roll mode gives 30,000 points per input channel for low frequency signal analysis
  • TrendPlot™ paperless recorder mode with deep memory for long-term automatic measurements
  • 5,000 count DMM included in the 2-channel models



Specifications:

Vertical deflection
Number of channels 4
Bandwidth 500 MHz
Rise time 0.7 ns
Number of scope inputs 4 input channels
Channel architecture All inputs fully insulated from each other and from ground Inputs may be activated in any combination
Input coupling AC or DC, with ground level indicator
Input sensitivity 2 mV/div to 100 V/div, plus variable attenuation
Bandwidth limiter User selectable: 10 kHz, or full bandwidth
Normal/invert/variable On each input channel, switched separately
Input voltage CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details
Vertical resolution 8 bit
Accuracy ± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
Input impedance 1 MΩ ± 1 % // 14 pF ± 2 pF
Horizontal
Maximum real-time sample rate (sampled simultaneously) 5 GS/s (single channel) or 1.25GS/s per channel
Record length Up to 10,000 samples per channel
Time base range 1 ns/div to 4 s/div
Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)
Maximum record length 10,000 samples per channel in scope mode
30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)
Timing accuracy ± (0.01 % of reading + 1 pixel)
Glitch capture 8 ns peak detect on each channel (using real time sampling and data compression, at any timebase setting)
Display and acquisition
Display 153 mm (6 in) full-color LCD with LED backlight
Display modes Any combination of channels; average on/off; replay
Visible screen width 12 divisions horizontally in scope mode
Digital persistence modes off/short/medium/long/infinite and envelope mode
Waveform mathematics One mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode Frequency Spectrum using FFT analysis
Acquisition modes Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and delay
Source Input A, B, C or D
Modes Automatic Connect-and-View™, free run, single shot, edge, delay, dual slope, video, video line, selectable pulsewidth (channel A only), N-cycle
Connect-and-View™ Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred.
Video triggering (on ch. A) NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select
High-res, non-interlaced video Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width triggering (on channel A) Pulse width qualified by time
Allows for triggering <t,>t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns </t,>
Time delay 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Dual slope triggering Triggers on both rising and falling edges alike
N-cycle triggering Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events.
Replay Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp.
Replay storage Two sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port.
FFT—frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window Automatic, Hamming, Hanning or None
Automatic window Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant
Vertical scale Linear/Logarithmic (in volts or amps))
Frequency axis Frequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform Compare Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope.
Pass/Fail Testing In waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis.
Automatic scope measurements
  V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), Power Factor (PF), Watts, VA, VA reactive, phase (between any 2 inputs), pulse width (pos./neg.), duty cycle (pos./neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 I and 600 I, VPWM ac and VPWM(ac+dc) for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ration (190-xx2 only)
Advanced power and motor drive functions V/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, VPWMac and VPWM (ac+dc) for measurement on pulsewidth modulated motordrives and frequency inverters
Advanced functions mA*s (current-over-time, between cursors)
V*s (voltage over time, between cursors)
W*s (energy, between cursors)
Cursor measurements
Source On any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Dual horizontal lines Voltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical lines Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors
Single vertical line Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant
ZOOM Ranges from full record overview to zoom in up to sample level, at any record length
Meter inputs Via BNC scope inputs
Number of readings Up to 4 simultaneously
Maximum resolution 999 Counts
Input impedance 1 MΩ ± 1 % // 15 pF ± 2 pF
Advanced meter functions Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording
The specified accuracy is valid over the temperature range 18 °C to 28 °C Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C
Voltage
V dc accuracy ± (1.5 % + 5 counts)
V ac true rms accuracy 15 Hz to 60 Hz: ± (1.5 % + 10 counts)
60 Hz to 1 kHz:
60 Hz to 20 kHz: ± (2.5 % + 15 counts)
V ac+dc true rms accuracy 15 Hz to 60 Hz: ± (1.5 % + 10 counts)
60 Hz to 20 kHz: ± (2.5 % + 15 counts)
Voltmeter ranges 500 mV, 5 V, 50 V, 500 V, 1,000 V
Other meter functions
Current (A) A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
Temperature With optional accessories. Scale factors 1mV/°C or 1mV/°F
ScopeRecord™ Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and display Any combination of inputs, up to 4 channels All channels sampled simultaneously
Memory depth 30,000 data points, each holding min/max pair of information
Min/max values Min/max values are created at samples that are measured at high sample rate ensuring capture and display of glitches.
Recording modes Single sweep, continuous roll
Start-on-Trigger (through any channel)
Stop-on-Trigger (through any channel)
Stop-on-trigger ScopeRecord mode can be stopped by an individual trigger event, or by an interruption of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series)
Horizontal scale Time from start, time of day
Zoom Ranges from full record overview to zoom in up to sample level, at any record length
Memory Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis Direct storage on external flash memory drive through USB host port
ScopeRecord™ Roll mode sample rate and recording timespan
Time base range 5 ms/div ~ 2 min/div
Recorded timespan 6 sec ~ 40 hr
Time/division in ‘view all’ mode 0.5 s/div ~ 4 h/div
Glitch capture 8 ns
Sample rate 125 MS/s
Resolution 200 μsec ~ 4.8 sec
Trendplot™ Recording
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time.
Source and display Any combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments)
Memory depth 19,200 points (sets) per measurement. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and time-stamp.
Ranges Normal view: 5 s/div to 30 min/div
In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time span Up to 22 days, with a resolution of 102 seconds
Recording mode Continuous recording, starting at 5 s/div with automatic record compression
Measurement speed Three automatic measurements per second or more
Horizontal scale Time from start, time of day
Zoom Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
Memory Two multiple input TrendPlot records can be saved internally for later recall and analysis
Direct storage on external flash memory drive through USB host port
Cursor measurements—all recorder modes
Source Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Dual vertical lines Cursors may be used to identify Min, Max or Average value of any datapoint in a record, with time between cursors, time from start or absolute time.
Input voltage range
Rated maximum floating voltage CAT III 1000 V/CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level)
Probe input voltage VPS410 CAT III 1000 V/CAT IV 600 V (Maximum voltage between 10:1 probe tip and reference lead)
Probe input voltage VPS510 CAT III 300 V (Maximum voltage between 10:1 probe tip and reference lead)
Maximum BNC input voltage CAT IV 300 V (maximum voltage on BNC input directly)
Memory save and recall
Memory locations (internal) 30 waveform memories plus 10 recording memories plus 9 screen copy memories
15 waveform memory locations Stores scope-trace waveform data (2 or 4 traces each) plus screen-copy plus corresponding setup
External data storage • On PC, using FlukeView™ Software, or
• Direct storage on external flash memory drive (maximum 2 GB) through USB host port
Two recording memories Each may contain:
• a 100 Screen Replay sequence, or
 • a ScopeRecord Roll-mode recording (2 or 4 traces), or
• a TrendPlot recording of up to 4 measurements
Screencopies • On PC, using FlukeView™ Software, or
• Internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port
Volatility Measurement data is initially stored in RAM, which is maintained by the main battery with a 30 seconds back-up when battery is exchanged. When storing data, this is written in non-volatile flash-ROM
Real-time clock Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings.
Mechanical Data
Size 265 mm x 190 mm x 70 mm (10.5 in x 7.5 in x 2.8 in)
Weight (including battery) 2.2 kg (4.8 lb)
Power
Line power Mains adapter/battery charger BC190 included, version depending of country
Battery power Re-chargeable double capacity Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument
Battery type (incl.) and capacity [+opt. battery] BP291: 4800 mAh
Battery charge indicator Battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen.
Battery operating time With baclklight Low ) Up to seven hours using BP291 (included)
Battery charging time Five hours BP291
Battery power saving functions Auto ‘power down’ with adjustable power down time
Auto ‘Display off’ with adjustable power down time
On-screen battery power indicator
Safety
Compliance EN61010-1-2001, Pollution Degree 2; CAN/CSA C22.2, No. 61010-1-04, with approval; UL61010B; ANSI/ISA-82.02.01
Environmental
Operating temperature 0 °C ~ +40 °C; 0 °C ~ +50 °C excluding battery
Storage temperature -20 °C ~ +60 °C
Humidity +10 °C ~ +30 °C: 95 % RH non-condensing
+30 °C ~ +40 °C: 75 % RH non-condensing
+40 °C ~ +50 °C: 45 % RH non-condensing
Maximum operating altitude Up to 2,000 m (6666 ft) for CAT IV 600 V/CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V/CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
Interfaces Two USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry USB-host port directly connects to external flash memory drive (up to 2 GB) for storage of waveform data, complete datasets in which data and setup information is included, instrument settings and screen copies A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control
Probe calibration output Dedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel



For full Fluke 190-504 product specifications, please click here: Fluke 190-504

Fluke 190-504 ScopeMeter 4 Channel 500MHz 5 GS/s Color Oscilloscope

The first high-performance portable oscilloscope with 4 independently insulated input channels, an IP51 dust- and dripwater proof rating and a CAT III 1000 V/CAT IV 600 V safety rating.

Includes Hard Carrying Case & Accessories As Listed

190 504 190504

Fluke 190-504 190504 ScopeMeter Oscilloscope Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 42565-L/T*

  • Fluke 190-504 ScopeMeter 500 MHz Oscilloscope (BC# 42565-L/T*)
  • Fluke VPS410-II-R Probe Set Red
  • Fluke VPS410-II-B Probe Set Blue
  • Fluke VPS410-II-V Probe Set Green
  • Fluke VPS410-II-G Prove Set Gray
  • (4) Fluke TRM50 50Ohm Terminator BNC
  • AC Adapter/Charger
  • Power Cord
  • USB PC Interface Cable
  • USB PC Interface Cable
  • Strap For Unit
  • User Manual ON CD-ROM
  • Hard Carrying Case
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!