Fluke 123B Industrial ScopeMeter 20MHz

Fluke 123B Industrial ScopeMeter 20MHz

Fluke 190-504 ScopeMeter 5GS/s 4 Channel 500MHz Oscilloscope

Fluke 190-504 ScopeMeter 5GS/s 4 Channel 500MHz Oscilloscope

Fluke 215C ScopeMeter 1GS/s Dual-Input 100 MHz HandHeld Color Oscilloscope 215 W/ Bushealth Option

$1,895.00
Availability: In stock
SKU
11H68

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Fluke 215C Scopemeter
The Fluke 225C and 215C are the instruments of choice for maintenance specialists who deal with industrial buses and networks as well as general electronics. You can verify the electrical integrity of your bus and network physical layer, performing tests and getting answers quickly and easily.

Based on the 200 MHz or 100 MHz 190C Series Color ScopeMeters, these instruments offer all the functions found in the 190C Series, plus added measurement capabilities for industrial networks such as Profi®, Foundation™, Modbus®, CAN-bus, AS-i bus, RS-485 and more.

Bus Health Test
Bus Health Test analyses the electrical signals on the industrial bus or network and gives a clear “Good”, “Weak” or “Bad” validation mark for each of the relevant parameters, presented next to the actual measurement value. Measured values are compared to standard values based on the selected bus type, or you may set your personal reference values if you need different tolerances. The Fluke 225C and 215C can make the signal quality validation as soon as electrical signals are passed along the network, without looking at the data content. They find errors like improper cable connections, bad contacts, incorrect grounding and missing or superfluous terminators.

Floating independently isolated input channels
Thanks to the independently isolated input channels and the floating inputs, the ScopeMeter can take floating differential measurements from balanced 2-wire systems such as RS-485 and CAN. One input channel can be connected to measure the voltage between the two signal wires, and the other can be connected to measure the common mode voltage over ground at the same time, independently.

Large color screen
The large color screen of the 225C and 215C shows the individual parameters with validation, the actual measured value, the minimum and maximum values recorded over time, and the reference values used for the validation. The choice of parameters differs with the bus type and may include bias voltage, signal high- and low-levels, rise- and fall-times, in-band and out-band noise levels, jitter, pulse width, baud rate, and more.

Activity indicators
The activity indicators tell you the data flow is ongoing and they stop flashing the moment communications come to a halt.

Signal integrity analysis
In the eye-pattern mode, a waveform display is built over successive signal passes to give you a visual indication of overall signal quality, noise levels and signal jitter.

Fluke 225C and 215C compared with other ScopeMeters
All ScopeMeters allow you to perform the basic electrical tests (such as copper resistance and isolation tests) on an electrical system or a cable. The Fluke 125 (see full line ScopeMeter brochure) supports industrial network verification using a common reference (“ground”) connection, and includes a 40 MHz Industrial ScopeMeter. The 225C and 215C give more extensive network analysis capabilities. Thanks to the isolated channel structure, the 225C and 215C give a far better immunity to common mode noise and disturbances and can measure common mode voltages separately. The 225C and 215C come with higher measurement speeds and give you all the measurement capabilities associated with the 190C Series.

Features:
  • Industrial Bus Health Test verifies electrical signal quality on industrial buses including Profi®, Foundation™, Modbus®, CAN-bus, AS-i bus, RS-485 and more
  • Easy signal validation of all relevant signal parameters
  • Complete 190C Color ScopeMeter® (200 MHz or 100 MHz model) built in
  • Floating and fully isolated inputs for true differential signal measurements

Specifications:
Oscilloscope mode
Bandwidth 100 MHz
Rise time 3.5 ns
Bandwidth limiter: User selectable: 10 kHz, 20 MHz or off
Number of inputs: Two plus external trigger. All inputs references isolated from each other and ground.
Input coupling: AC or dc, with ground level indicator
Input sensitivity: 2 mV/div to 100 V/div
Normal/invert: On both input channels; switched separately
Variable attenuator: Variable gain on input channel A
Input voltage: 1000 V CAT II, 600 V CAT III rated—see “general specifications” for further details
Vertical resolution: 8 bit
Accuracy: ± (1.5 % of reading + 0.04 x range/div)
Input impedance: 1 MW ± 1 % // 15 pF ± 2 pF
Maximum real-time sample rate 1 GS/s
Number of digitizers 2
Time base range 5 ns/div to 5 s/div
Maximum record length: 3000 points per input in Scope mode; 27,500 points per input in ScopeRecord™ roll mode (5 ms/div to 2 min/div)
Accuracy: ± (0.01 % of reading + 1 pixel)
Glitch capture: 50 nsec (5 μsec/div to 1 min/div)
Display and acquisition
Display: 144 mm full-color LCD, with backlight
Display modes: Input A, input B, dual, average, Replay
Visible screen width: 12 divisions
Waveform mathematics: A + B, A - B, A * B, all with user selectable scaling of resultant; A versus B (X - Y mode); Frequency spectrum using FFT analysis
Acquisition modes: Normal, auto, single shot, ScopeRecord™ roll, glitch capture, waveform compare, waveform compare with automatic “Pass / Fail testing”, Bus Health test mode (225C and 215C only), Eyepattern Display of single ended or differential bus signal (Fluke 225C and 215C only).
Trigger and delay
Source: Input A, input B, external trigger input. All input references isolated from each other and from ground
Modes: Automatic Connect-and-View,™ free run, single shot, edge, delay, video, video line, selectable pulsewidth, dual slope, N-cycle
Connect-and-View™: Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if desired.
Video triggering: NTSC, PAL, PAL+, SECAM. Includes field 1, field 2 and line select
Horizontal
Pulse width triggering: Pulse width qualified by time. Allows for triggering t, =t, ≠t, where t is selectable in minimal steps of 0.01 div. or 50 nsec.
Time delay: One full screen of pre-trigger view or up to 100 screens (= 1200 divisions) of post-trigger delay
Dual slope triggering: Triggers on both rising and falling edges alike
N-cycle triggering: Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
Automatic capture of 100 screens The instrument ALWAYS memorizes the last 100 screens (no user setup required). When an anomaly occurs on screen, the REPLAY button can be pressed to review the full screen sequence over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 events.
Replay: Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp
Replay storage: Up to 2 sets of 100 screens each can be saved for later recall and analysis
FFT – Frequency spectrum analysis Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window: Automatic, Hamming, Hanning or None
Automatic window: Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant
Vertical scale: Linear/logarithmic, in volts
Frequency axis: Logarithmic; frequency range automatically set as function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform compare: Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the ScopeMeter or externally using FlukeView® Software.
Pass/Fail Testing: In waveform compare mode, the Color Scopemeter can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis.
Automatic scope measurements V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (Hz), risetime, falltime, power factor, Watts, VA, VA reactive, phase, pulse width (pos/neg), dutycycle (pos/neg), temperature °C, temperature °F, dBV, dBm into 50 Ω and 600 Ω Vpwm ac, Vpwm ac+dc for measurement on pulse width modulated motordrives and frequency inverters
Cursor measurements
Source: Input A, input B or the mathematical result trace (excluding A vs B curve)
Dual horizontal lines: Voltage at cursor 1 and 2, voltage between cursors
Dual vertical lines: Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors
Single vertical line: Min-Max and average voltage at cursor position; frequency and rms-value of individual frequency component in FFT result
General specifications
Input voltage ratings
Maximum probe voltage: CAT II 1,000 V, CAT III 600 V (Maximum voltage between 10:1 probe tip (VPS210) and reference lead)
Floating voltage: CAT II 1,000V, CAT III 600 V (Maximum voltage between earth ground and any terminal (signal input or shielding))
Independently isolated inputs: CAT II 1,000 V, CAT III 600 V (Maximum voltage between any terminal of one input or probe (VPS210) and any other terminal of another input or probe (VPS210))
Maximum voltage on BNC input directly (input A or B): CAT III 300 V
Maximum voltage on meter input: CAT II 1,000 V, CAT III 600 V
Memory save and recall
Scope memories: 15 memory locations that each can contain two waveforms plus corresponding setup. With each storage action, a user specified name (20 ASCII characters long) can be assigned to the stored data, for easier reference
Recorder memories: 2 memory locations that each can contain 100 captured dual input scope screens, or a dual input ScopeRecord (27,500 Min-Max pairs per input), or a dual input Trendplot (18,000 min-max pairs + average values)
Real-time clock Time and date stamp for ScopeRecord, 100 captured screens and TrendPlots
Mechanical data
Size: `256 mm x 169 mm x 64 mm (10.1 in x 6.6 in x 2.5 in)
Weight: 2 kg (4.4 lbs)
Power
Line power: Country-specific line voltage
Battery power: Rechargeable NiMH (installed)
Battery operating time: 4 hours
Battery charging time: 4 hours
Battery power saving functions: Auto power down with adjustable power down time. On-screen battery status indicator
Safety
Compliance: EN61010-1-2001, Pollution degree 2; UL61010B, with approval; CAN/CSA C22.2, No. 61010-1-04, with approval; ANSI/ISA-82.02.01
Input voltage ratings
Maximum probe voltage: CAT II 1000 V/ CAT III 600 V (Maximum voltage between 10:1 probe tip [VPS200] and reference lead)
Floating voltage: CAT II 1000 V/ CAT III 600 V (Maximum voltage between earth ground and any terminal [signal input or shielding])
Independently isolated inputs: CAT II 1000 V/ CAT III 600 V (Maximum voltage between any terminal of one input or probe [VPS200] and any other terminal of another input or probe [VPS200])
Maximum voltage on BNC input directly (input A or B): CAT III 300 V
Maximum voltage on meter input: CAT II 1,000 V/ CAT III 600 V
Environmental
Operating temperature: 0 °C to +50 °C
Storage temperature: -20 °C to +60 °C
Humidity: 10 °C to 30 °C: 95 % RH non condensing
30 °C to 40 °C: 75 % RH non condensing
40 °C to 50 °C: 45 % RH non condensing
Maximum operating altitude: 3,000 m (10,000 feet)
Maximum storage altitude: 12 km (40,000 feet)
Electro-Magnetic-Compatibility (EMC): EN 61326-1 for emission and immunity



For full Fluke 215C Scopemeter product specifications, please click here: Fluke 215C Scopemeter

Fluke 215C ScopeMeter, 1GS/s Dual-Input 100MHz HandHeld Oscilloscope With Bushealth Option

This instrument offers all the functions found in the 190C Series, plus added measurement capabilities for industrial networks such as Profi®, Foundation™, Modbus®, CAN-bus, AS-i bus, RS-485 and more.

Includes Carrying Case & Accessories As Listed

Fluke 215C Fluke-215C Scopemeter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 41450-L/T*

  • Fluke 215C ScopeMeter 100MHz Oscilloscope (BC# 41450-L/T*)  
    • Installed Options:
      • Bushealth
  • (2) Fluke Voltage Probes
  • (2) Fluke Hard Point Test Leads
  • (2) Fluke Ground Leads w/ Hook Clips
  • (2) Fluke Ground Leads w/ Mini Clips
  • (2) Fluke Hook Clips
  • (2) Fluke Flexible Test Leads
  • (2) Fluke Test Pins
  • (2) Fluke Alligator Clips
  • (2) Fluke Coaxial Cables
  • AC Adapter/Charger
  • Fluke ScopeMeter Getting Started Guide
  • User Manual On CD-ROM
  • Carrying Case (G)
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!