Fluke 433 HandHeld Power Quality Analyzer Meter
$0.00
Availability:
Out of stock
SKU
PQ02
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Request a Quote for
The Fluke 434 and 433 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-to-use handhelds are a モmust haveヤ for any person who maintains or troubleshoots three phase distribution. The new IEC standards for flicker and power quality are built right in to take the guess work out of monitoring.
- Records all your necessary values in a three phase system.
- Minimal setup required with intuitive menus.
- Highest safety rating in the industry.
- Four voltage and four current channels.
- Captures waveform data on all phases simultaneously.
- System-Monitor: Six power quality parameters on one dashboard
- Automatic Transient display: Never miss an event.
- Auto Trend: Donメt waste time setting up recordings.
- Rugged, handheld recorder.
- Seven hours operating time per charge on NiMH battery pack.
- Transfer data files to your PC for reporting and analysis using FlukeView® software.
Specifications:
Input characteristics | |
Voltage inputs | |
Number of inputs | 4 (3 phases + neutral) |
Maximum input voltage | 1000 Vrms |
Maximum peak voltage | 6 kV |
Input impedance | 4 MW / 5 pF |
Band | 9 kHz, up to 100 kHz for transient display |
Scaling | 1:1, 10:1, 100:1, 1000:1 and variable |
Current inputs | |
Number of inputs | 4 (3 phases + neutral) |
Type | Clamp on current transformer with mV output |
Range | 1 to 400 Arms with included clamps (I400S) 0.1 to 3000 Arms with optional clamps |
Input impedance | 50 kW |
Band | 9 kHz |
Scaling | 0.1, 1, 10, 100, 1000 mV/A and variable |
Nominal frequency | 40 to 70 Hz |
Sampling system | |
Resolution | 16 bit analog to digital converter on 8 channels |
Maximum sampling speed | 200 kS/s on each channel simultaneously |
RMS sampling | 5000 samples on 10/122 cycles according IEC 61000-4-30 |
PLL synchronization | 4096 samples on 10/122 cycles according IEC 61000-4-7 |
Display modes | |
Waveform display | Available in Scope and Transient mode Captures 8 waveforms simultaneously Display update rate 5 x per second Up to 10/12 times horizontal zoom2 Cursors: Single vertical line showing min, max, avg reading at cursor position |
Phasor | Shows real time phasor diagram Available in Scope and Unbalance mode Display update rate 5 x per second |
Matrix readings | Available in Volts/Amps/Hertz, Harmonics, Power & Energy, Flicker and Unbalance mode |
AutoTrend graph | Available in Volts/Amps/Hertz, Dips & Swells, Harmonics, Power & Energy, Flicker, Unbalance, Inrush and Monitor mode Cursors: single vertical line showing with min, max, avg reading at cursor position |
Bargraph | Available in Harmonics and Monitor mode |
Eventlist | Available in Dips & Swells and Monitor mode |
Measurement modes | |
Scope | Vrms, Arms, Vcursor, Acursor, Vfund, Afund, Hz, V phase angles, A phase angles |
Volts/Amps/Hertz | Vrms, Vpk, V Crest Factor, Arms, Apk, A Crest Factor, Hz |
Dips and Swells | Vrms1.2 , Arms1.2 Captures up to 1000 events with date, time, duration, magnitude and phase identification with programmable thresholds |
Harmonics DC, 1 to 50 | Harmonic Volts, THD Volt, Harmonic Amps, THD Amps, K Amps, Harmonic Watts, THD Watts, K Watts, Interharmonic Volts4, Interharmonic Amps4 (relative to fundamental or to total rms) |
Power and Energy4 | Watts, VA, VAR, Power factor, Cos j / DPF, Arms, Vrms, kWh, kVAh, KVARh, peak demand interval using trend, KYZ revenue meter verification via optional input |
Flicker | Pst(1min), Pst, Plt, PF5, Vrms1.2 , Arms1.2 , Dc, Dmax, TDEX |
Unbalance | Vneg, Vzero, Aneg, Azero, Vfund, Afund, Hz, V phase angles, A phase angles |
Transients4 | Vrms, Arms, Vcursor, Acursor |
Inrush Currents4 | Inrush Current, Inrush duration, Arms1.2, Vrms1.2 |
System Monitor | Vrms, Arms, Harmonic Volts, THD Volts, Plt, Vrms1.2 , Arms1.2 , Vneg, Hz, dips and swells, unbalance. All parameters are measured simultaneously in accordance with EN50160. Using Flagging to indicate unreliable readings according IEC61000-4-30. |
Accuracy, resolution and range | |||
Volt/Amps/Hertz | Measurement range | Resolution | Accuracy |
Vrms (AC+DC) | 1 to 1000 Vrms | 0.1 Vrms | ± 0.5 % of nominal voltage |
Vpk | 1 to 1400 Vpk | 1 V | 5 % of nominal voltage |
CFV | 1.0 to > 2.8 | 0.1 | ± 5 % |
Arms (AC+DC) with included clamps | 0 to 20,000 Arms1 0 to 400 Arms | 0,001 to 10 Arms1 0.1 and 1 Arms | ± 1 % of reading ± 5 counts3 |
Apk using 1mV/A scaling | 0 - 5500 Apk | 10:00 AM | ± 5 % |
CFA using 1mV/A scaling | 1 to 10 | 0.1 | ± 5 % |
50 Hz nominal | 42.50 to 57.50 Hz | 0.01 Hz | ± 0.1 % of nominal frequency |
60 Hz nominal | 51.00 to 69.00 Hz | 0.01 Hz | ± 0.1 % of nominal frequency |
Dips and swells | |||
Vrms1.2 (AC+DC) | 0.0 to100 % of nominal voltage | 0.1Vrms | ± 1 % of nominal voltage |
Arms1.2 (AC+DC) with included clamps | 0 to 20,000 Arms 0 to 400 Arms | 0,001 Arms to 10 Arms 0.1 Arms and 1 Arms | ± 1 % of reading ± 5 counts3 |
Threshold levels | Programmable in percent of nominal voltage | ||
Duration | hhh,mm,ss,mmm with half-cycle cycle time resolution | ||
Harmonics | |||
Harmonic selection (n) | DC, 1 to 50 | ||
Inter-Harmonic selection | Off, 1 to 49 | ||
Vrms Relative (%f): Absolute: | 0.0 to 100.0 % 0.0 to 1000 Vrms | 0.1 % 0.1 Vrms | ± 0.1 % ± n x 0.1 % (± 0.4 % for %r) ± 5 % of reading ± 2 counts |
Arms Relative (%f): Absolute: | 0.0 to 100.0 % 0.0 to 4000 mV x selected clamp scaling | 0.1 % 1 mVrms x selected clamp scaling | ± 0.1 % ± n x 0.1 % (± 0.4 % for %r) ± 5 % of reading ± 5 counts |
Watts Relative: Absolute: | 0.0 to 100.0 % depends on selected clamp and voltage scaling | 0.10% | ± n x 2 % ± 5 % of reading ± n x 2 % of reading, ± 10 counts |
DC voltage Relative: Absolute: | 0.0 to 100.0 % 0.0 to 1000 V | 0.1 % 0.1 V | ± 1 % ± 5 % of reading ± 10 counts |
THD | 0.0 to 100.0 % | 0.10% | ± 2.5 % |
Hz | 0 to 3500 Hz | 1 Hz | ± 1Hz |
Phase angle | -360 o to +360 o | 1 o | ± n x 1.5 o |
Power and Energy | |||
Watt | 1.0 W to 20.00 MW1 | 0.1 W to 1 kW1 | ± 1.5 % of reading ± 10 counts3 |
VA | 1.0 VA to 20.00 MVA1 | 0.1 VA to 1 kVA1 | ± 1.5 % of reading ± 10 counts3 |
VAR | 1.0 VAR to 20.00 MVAR1 | 0.1 VAR to 1 kVAR1 | ± 1.5 % of reading ± 10 counts3 |
kWh | 00.00 kWhr to 200.0 GWhr1 | 0.01 Whr to 100 Whr1 | ± 1.5 % of reading ± 10 counts3 |
kVA | 00.00 kVAhr to 200.0 GVAhr1 | 0.01 VAhr to 100 VAhr1 | ± 1.5 % of reading ± 10 counts3 |
kVAR | 00.00 kVARhr to 200.0 GVARhr1 | 0.01 VARhr to 100 VARhr1 | ± 1.5 % of reading ± 10 counts3 |
Power Factor | 0 to 1 | 0.01 | ± 0.033 |
Cos j / DPF | 0 to 1 | 0.01 | ± 0.033 |
Flicker | |||
Pst (1min), Pst, Plt, PF5 instantenous Flicker | 0.00 to 20.00 | 0.01 | Within ± 5 % of tabulated values according IEC61000-4-15 |
Dc %, Dmax % and Time d(t) exceeds limits. As described per IEC 61000-3-3 | 0.0 to ± 100.0 % for Dc % and Dmax % and 0.000 to 9.999s for Time | 0.1 % for Dc % and Dmax % and 10 ms for Time | ± 1% for Dc % and Dmax % and 20 ms for Time |
Unbalance | |||
Volts | 0.0 to 5.0 % | 0.10% | ± 0.5 % |
Current | 0.0 to 20 % | 0.10% | ± 1 % |
Transient capture | |||
Volts | ± 6000 Vpk | 1 V | ± 15 % of cursor reading ± 2.5 % of Vrms |
Minimum detect duration | 5 テÊs | Sampling rate | 200 kS/s |
Inrush mode | |||
Arms (AC+DC) | 0.000 to 20.00 kArms1 | 0.001 to 10 Arms1 | ± 1 % of meas ± 5 counts3 |
Inrush Duration | mm:ss:mmm between 7.5 s to 30 m selectable | 10 ms | ± 20 ms (Fnominal = 50 Hz) |
Trend recording | |
Method | AutoTrend automatically records min, max and average values over time for all readings being displayed for the 3 phases and neutral simultaneously |
Volts/amps/hertz, harmonics, power and energy, flicker and unbalance mode | |
Sampling | 5 readings/sec continuous sampling per channel |
Memory | 1800 min, max and avg points for each reading |
Recording time | From 30 min with 1 second display resolution up to 450 days with 6 hour display resolution |
Zoom | Up to 6 x horizontal zoom |
Dips and swells mode | |
Sampling | 100/1202 readings/sec continuous sampling per channel |
Memory | 3600 min, max and avg points for each reading |
Recording time | From 90 sec with 25 msec display resolution up to 450 days with 3 hour display resolution |
Zoom | Up to 12 x horizontal zoom |
Inrush currents and flicker PF5 mode | |
Sampling | 100/1202 readings/sec continuous sampling per channel |
Memory | 3600 min, max and avg points for each reading |
Recording time | From 7.5 sec with 25 msec display resolution up to 30 min with 500 msec display resolution for Inrush measurements and up to 2.5 hour with 2.5 sec display resolution for PF5 recordings |
Zoom | Up to 12 x horizontal zoom |
Monitor mode | |
Sampling | Combination of 5 readings/sec and 100/1202 readings/sec continuous sampling per channel depending on the parameter measured |
Recording time | Up to 1 week with 10 min resoluton |
Memory | 1008 min, max and avg points for each reading |
Limits | According EN50160 or customer definable |
Measurement method | |
Vrms, Arms | 10/122 cycle contiguous non overlapping intervals using 500/4162 samples per cycle in accordance with IEC 61000-4-30 |
Vpeak, Apeak | Absolute highest sample value within 10/122 cycle interval with 40 テÊs sample resolution |
V Crest Factor | Measures ratio between the Vpeak and Vrms |
A Crest Factor | Measures ratio between the Apeak and Arms |
Hz | Measured every 10 sec in accordance with IEC61000-4-30 |
Vrms1.2 , Arms1.2 | Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle. This technique is independent for each channel in accordance with IEC 61000-4-30. |
Harmonics | Calculated from 10/12-cycle gapless harmonic group measurements on Voltage and Amps according to IEC 61000-4-7 |
Watt | Selectable Total or Fundamental real power display Calculates average value of instantaneous power over 10/12 cycle period for each phase Total Active Power PT =P1 + P2 + P3 |
VA | Selectable Total or Fundamental apparent power display Calculates apparent power using Vrms x Arms value over 10/12 cycle period Total Apparent Power is root mean square of real and apparent power |
VAR | Selectable Total of Fundamental reactive power display Calculates reactive power as root of VA squared minus Watt squared over 10/12 cycle period Capacitive and inductive load is indicated with capacitor and inductor icons |
Power Factor | Calculated Watt / VA |
Cos j / DPF | Cos of angle between fundamental voltage and current |
Unbalance | The supply voltage unbalance is evaluated using the method of symmetrical components according to IEC61000-4-30 |
Flicker | According to IEC 61000-4-15 Flickermeter - Functional and design specification Includes 230 V 50 Hz lamp and 120 V 60 Hz lamp models |
Transient capture | Captures waveform triggered on signal envelope Additionally triggers on dips, swells, interruptions and Amps level as specified by IEC61000-4-30 |
Inrush current | The inrush current begins when the Arms half cycle rises above the inrush threshold, and ends when the Arms half cycle rms is equal to or below the inrush threshold minus a user-selected hysteresis value. The measurement is the square root of the mean of the squared Arms half cycle values measured during the inrush duration. Each half-cycle interval is contiguous and non-overlapping as recommended by IEC 61000-4-30. Markers indicate inrush duration. Cursors allow measurement of peak Arms half cycle. |
General | |
Case | |
Design | Rugged, shock proof with integrated protective holster |
Drip and dust proof | IP51 according to IEC60529 when used in tilt stand position |
Shock and Vibration | Shock 30 g, Vibration: 3 g Sinusoid, Random 0.03 g2/Hz according to MIL-PRF-28800F Class 2 |
Display | |
Type | Bright Full-Color LCD with CCFL backlight, 80cd/m2 |
Size | 115.2 x 86.4 mm (4.5 x 3.4 in) |
Resolution | 320 x 240 pixels |
Contrast and brightness | User adjustable, temperature compensated |
Memory | |
Screens | 50 screen memories on Fluke 434 25 screen memories on Fluke 433 |
Data | 10 data memories for storing data including recordings on Fluke 434 5 data memories for storing data including recordings on Fluke 433 |
Limit templates | 2 preprogrammed, 2 administrator (programmable via FlukeView, 2 user locations) |
Real-time clock | Time and date stamp for AutoTrend, Transient display and SystemMonitor |
Size | 256 x 169 x 64 mm (10 x 6.6 x 2.5 in.) |
Weight | 2 kg (4.4 lb.) |
Mechanical | |
Line power | Switchable 115 V, 230 V adapter with country specific plug |
Battery power | Rechargeable NiMH (installed) |
Battery operating time | > 7 hours |
Battery charging time | 4 hours |
Power saving | Adjustable time for dimmed backlight with on screen power indicator |
Power | |
Measurement methods used | IEC61000-4-30 class A |
Power Quality | EN50160 |
Flicker | IEC 61000-4-15 |
Harmonics | IEC 61000-4-7 |
Standards | |
Compliance | IEC/EN61010-1 (2nd edition) pollution degree 2; CAN/CSA C22.2 No 101.1; ANSI/ISA S82.01 |
Max voltage on banana input | CAT III 1000 V / CAT IV 600 V |
Max voltage on current BNC input | 42 Vpeak |
Safety | |
Operating temperature | 0 °C to +50 °C (32 °F to 122 °F) |
Storage temperature | -20 °C to +60 °C (-4 °F to 140 °F) |
Humidity | 10 to 30 °C: 95 % RH non condensing (50 to 86 °F: 95 % RH non condensing) 30 to 40 °C: 75 % RH non condensing (86 to 104 °F: 75 % RH non condensing) 40 to 50 °C: 45 % RH non condensing (104 to 122 °F: 45 % RH non condensing) |
Maximum operating altitude | 3000 m (9842 ft) Derate to CAT II 1000 V / CAT III 600 V / CAT IV 300 V above 2000 m (6561 ft) |
Maximum storage altitude | 12 km (39,372 ft) |
For full Fluke 433 specifications, please click here: Fluke 433
Fluke 433 HandHeld Power Quality Analyzer
Includes (4) Fluke i400s AC Current Clamps, Hard Carrying Case & Accessories As Listed
Fluke 433 Fluke-433 Power Quality Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 16491
- Fluke 433 Power Quality Analyzer (BC# 16491)
- (4) Fluke i400s AC Current Clamps
- (5) Fluke TLS430 Test Leads
- (4) Fluke Alligator Clips
- Fluke 433 Getting Started Guide
- Fluke Power Quality Analyzer Software
- AC Adapter/Charger
- Strap For Unit
- Hard Carrying Case