The Fluke 434 and 433 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-to-use handhelds are a モmust haveヤ for any person who maintains or troubleshoots three phase distribution. The new IEC standards for flicker and power quality are built right in to take the guess work out of monitoring.

  • Records all your necessary values in a three phase system.
  • Minimal setup required with intuitive menus.
  • Highest safety rating in the industry.
  • Four voltage and four current channels.
  • Captures waveform data on all phases simultaneously.
  • System-Monitor: Six power quality parameters on one dashboard
  • Automatic Transient display: Never miss an event.
  • Auto Trend: Donメt waste time setting up recordings.
  • Rugged, handheld recorder.
  • Seven hours operating time per charge on NiMH battery pack.
  • Transfer data files to your PC for reporting and analysis using FlukeView® software.

Specifications:

 

Input characteristics
Voltage inputs 
Number of inputs  4 (3 phases + neutral) 
Maximum input voltage  1000 Vrms 
Maximum peak voltage  6 kV 
Input impedance  4 MW / 5 pF 
Band  9 kHz, up to 100 kHz for transient display 
Scaling  1:1, 10:1, 100:1, 1000:1 and variable 
Current inputs 
Number of inputs  4 (3 phases + neutral) 
Type  Clamp on current transformer with mV output 
Range  1 to 400 Arms with included clamps (I400S) 0.1 to 3000 Arms with optional clamps 
Input impedance  50 kW 
Band  9 kHz 
Scaling  0.1, 1, 10, 100, 1000 mV/A and variable 
Nominal frequency  40 to 70 Hz 
Sampling system 
Resolution  16 bit analog to digital converter on 8 channels 
Maximum sampling speed  200 kS/s on each channel simultaneously 
RMS sampling  5000 samples on 10/122 cycles according IEC 61000-4-30 
PLL synchronization  4096 samples on 10/122 cycles according IEC 61000-4-7 
Display modes
Waveform display  Available in Scope and Transient mode Captures 8 waveforms simultaneously Display update rate 5 x per second Up to 10/12 times horizontal zoom2 Cursors: Single vertical line showing min, max, avg reading at cursor position 
Phasor  Shows real time phasor diagram Available in Scope and Unbalance mode Display update rate 5 x per second 
Matrix readings  Available in Volts/Amps/Hertz, Harmonics, Power & Energy, Flicker and Unbalance mode 
AutoTrend graph  Available in Volts/Amps/Hertz, Dips & Swells, Harmonics, Power & Energy, Flicker, Unbalance, Inrush and Monitor mode Cursors: single vertical line showing with min, max, avg reading at cursor position 
Bargraph  Available in Harmonics and Monitor mode 
Eventlist  Available in Dips & Swells and Monitor mode 
Measurement modes
Scope  Vrms, Arms, Vcursor, Acursor, Vfund, Afund, Hz, V phase angles, A phase angles 
Volts/Amps/Hertz  Vrms, Vpk, V Crest Factor, Arms, Apk, A Crest Factor, Hz 
Dips and Swells  Vrms1.2 , Arms1.2 Captures up to 1000 events with date, time, duration, magnitude and phase identification with programmable thresholds 
Harmonics DC, 1 to 50  Harmonic Volts, THD Volt, Harmonic Amps, THD Amps, K Amps, Harmonic Watts, THD Watts, K Watts, Interharmonic Volts4, Interharmonic Amps4 (relative to fundamental or to total rms) 
Power and Energy4  Watts, VA, VAR, Power factor, Cos j / DPF, Arms, Vrms, kWh, kVAh, KVARh, peak demand interval using trend, KYZ revenue meter verification via optional input 
Flicker  Pst(1min), Pst, Plt, PF5, Vrms1.2 , Arms1.2 , Dc, Dmax, TDEX 
Unbalance  Vneg, Vzero, Aneg, Azero, Vfund, Afund, Hz, V phase angles, A phase angles 
Transients4  Vrms, Arms, Vcursor, Acursor 
Inrush Currents4  Inrush Current, Inrush duration, Arms1.2, Vrms1.2 
System Monitor  Vrms, Arms, Harmonic Volts, THD Volts, Plt, Vrms1.2 , Arms1.2 , Vneg, Hz, dips and swells, unbalance. All parameters are measured simultaneously in accordance with EN50160. Using Flagging to indicate unreliable readings according IEC61000-4-30. 

Accuracy, resolution and range
Volt/Amps/Hertz  Measurement range  Resolution  Accuracy 
Vrms (AC+DC)  1 to 1000 Vrms  0.1 Vrms  ± 0.5 % of nominal voltage 
Vpk  1 to 1400 Vpk  1 V  5 % of nominal voltage 
CFV  1.0 to > 2.8  0.1 ± 5 % 
Arms (AC+DC) with included clamps  0 to 20,000 Arms1 0 to 400 Arms  0,001 to 10 Arms1 0.1 and 1 Arms  ± 1 % of reading ± 5 counts3 
Apk using 1mV/A scaling  0 - 5500 Apk  10:00 AM ± 5 % 
CFA using 1mV/A scaling  1 to 10  0.1 ± 5 % 
50 Hz nominal  42.50 to 57.50 Hz  0.01 Hz  ± 0.1 % of nominal frequency 
60 Hz nominal  51.00 to 69.00 Hz  0.01 Hz  ± 0.1 % of nominal frequency 
Dips and swells 
Vrms1.2 (AC+DC)  0.0 to100 % of nominal voltage  0.1Vrms  ± 1 % of nominal voltage 
Arms1.2 (AC+DC) with included clamps  0 to 20,000 Arms 0 to 400 Arms  0,001 Arms to 10 Arms 0.1 Arms and 1 Arms  ± 1 % of reading ± 5 counts3 
Threshold levels  Programmable in percent of nominal voltage 
Duration  hhh,mm,ss,mmm with half-cycle cycle time resolution 
Harmonics 
Harmonic selection (n)  DC, 1 to 50 
Inter-Harmonic selection  Off, 1 to 49 
Vrms Relative (%f): Absolute:  0.0 to 100.0 % 0.0 to 1000 Vrms  0.1 % 0.1 Vrms  ± 0.1 % ± n x 0.1 % (± 0.4 % for %r) ± 5 % of reading ± 2 counts 
Arms Relative (%f): Absolute:  0.0 to 100.0 % 0.0 to 4000 mV x selected clamp scaling  0.1 % 1 mVrms x selected clamp scaling  ± 0.1 % ± n x 0.1 % (± 0.4 % for %r) ± 5 % of reading ± 5 counts 
Watts Relative: Absolute:  0.0 to 100.0 % depends on selected clamp and voltage scaling  0.10% ± n x 2 % ± 5 % of reading ± n x 2 % of reading, ± 10 counts 
DC voltage Relative: Absolute:  0.0 to 100.0 % 0.0 to 1000 V  0.1 % 0.1 V  ± 1 % ± 5 % of reading ± 10 counts 
THD  0.0 to 100.0 %  0.10% ± 2.5 % 
Hz  0 to 3500 Hz  1 Hz  ± 1Hz 
Phase angle  -360 o to +360 o  1 o  ± n x 1.5 o 
Power and Energy 
Watt  1.0 W to 20.00 MW1  0.1 W to 1 kW1  ± 1.5 % of reading ± 10 counts3 
VA  1.0 VA to 20.00 MVA1  0.1 VA to 1 kVA1  ± 1.5 % of reading ± 10 counts3 
VAR  1.0 VAR to 20.00 MVAR1  0.1 VAR to 1 kVAR1  ± 1.5 % of reading ± 10 counts3 
kWh  00.00 kWhr to 200.0 GWhr1  0.01 Whr to 100 Whr1  ± 1.5 % of reading ± 10 counts3 
kVA  00.00 kVAhr to 200.0 GVAhr1  0.01 VAhr to 100 VAhr1  ± 1.5 % of reading ± 10 counts3 
kVAR  00.00 kVARhr to 200.0 GVARhr1  0.01 VARhr to 100 VARhr1  ± 1.5 % of reading ± 10 counts3 
Power Factor  0 to 1  0.01 ± 0.033 
Cos j / DPF  0 to 1  0.01 ± 0.033 
Flicker 
Pst (1min), Pst, Plt, PF5 instantenous Flicker  0.00 to 20.00  0.01 Within ± 5 % of tabulated values according IEC61000-4-15 
Dc %, Dmax % and Time d(t) exceeds limits. As described per IEC 61000-3-3  0.0 to ± 100.0 % for Dc % and Dmax % and 0.000 to 9.999s for Time  0.1 % for Dc % and Dmax % and 10 ms for Time  ± 1% for Dc % and Dmax % and 20 ms for Time 
Unbalance 
Volts  0.0 to 5.0 %  0.10% ± 0.5 % 
Current  0.0 to 20 %  0.10% ± 1 % 
Transient capture 
Volts  ± 6000 Vpk  1 V  ± 15 % of cursor reading ± 2.5 % of Vrms 
Minimum detect duration  5 テÊs  Sampling rate  200 kS/s 
Inrush mode 
Arms (AC+DC)  0.000 to 20.00 kArms1  0.001 to 10 Arms1  ± 1 % of meas ± 5 counts3 
Inrush Duration  mm:ss:mmm between 7.5 s to 30 m selectable  10 ms  ± 20 ms (Fnominal = 50 Hz) 
 
Trend recording
Method  AutoTrend automatically records min, max and average values over time for all readings being displayed for the 3 phases and neutral simultaneously 
Volts/amps/hertz, harmonics, power and energy, flicker and unbalance mode 
Sampling  5 readings/sec continuous sampling per channel 
Memory  1800 min, max and avg points for each reading 
Recording time  From 30 min with 1 second display resolution up to 450 days with 6 hour display resolution 
Zoom  Up to 6 x horizontal zoom 
Dips and swells mode 
Sampling  100/1202 readings/sec continuous sampling per channel 
Memory  3600 min, max and avg points for each reading 
Recording time  From 90 sec with 25 msec display resolution up to 450 days with 3 hour display resolution 
Zoom  Up to 12 x horizontal zoom 
Inrush currents and flicker PF5 mode
Sampling  100/1202 readings/sec continuous sampling per channel 
Memory  3600 min, max and avg points for each reading 
Recording time  From 7.5 sec with 25 msec display resolution up to 30 min with 500 msec display resolution for Inrush measurements and up to 2.5 hour with 2.5 sec display resolution for PF5 recordings 
Zoom  Up to 12 x horizontal zoom 
Monitor mode 
Sampling  Combination of 5 readings/sec and 100/1202 readings/sec continuous sampling per channel depending on the parameter measured 
Recording time  Up to 1 week with 10 min resoluton 
Memory  1008 min, max and avg points for each reading 
Limits  According EN50160 or customer definable 
Measurement method
Vrms, Arms  10/122 cycle contiguous non overlapping intervals using 500/4162 samples per cycle in accordance with IEC 61000-4-30 
Vpeak, Apeak  Absolute highest sample value within 10/122 cycle interval with 40 テÊs sample resolution 
V Crest Factor  Measures ratio between the Vpeak and Vrms 
A Crest Factor  Measures ratio between the Apeak and Arms 
Hz  Measured every 10 sec in accordance with IEC61000-4-30 
Vrms1.2 , Arms1.2  Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle. This technique is independent for each channel in accordance with IEC 61000-4-30. 
Harmonics  Calculated from 10/12-cycle gapless harmonic group measurements on Voltage and Amps according to IEC 61000-4-7 
Watt  Selectable Total or Fundamental real power display Calculates average value of instantaneous power over 10/12 cycle period for each phase Total Active Power PT =P1 + P2 + P3 
VA  Selectable Total or Fundamental apparent power display Calculates apparent power using Vrms x Arms value over 10/12 cycle period Total Apparent Power is root mean square of real and apparent power 
VAR  Selectable Total of Fundamental reactive power display Calculates reactive power as root of VA squared minus Watt squared over 10/12 cycle period Capacitive and inductive load is indicated with capacitor and inductor icons 
Power Factor  Calculated Watt / VA 
Cos j / DPF  Cos of angle between fundamental voltage and current 
Unbalance  The supply voltage unbalance is evaluated using the method of symmetrical components according to IEC61000-4-30 
Flicker  According to IEC 61000-4-15 Flickermeter - Functional and design specification Includes 230 V 50 Hz lamp and 120 V 60 Hz lamp models 
Transient capture  Captures waveform triggered on signal envelope Additionally triggers on dips, swells, interruptions and Amps level as specified by IEC61000-4-30 
Inrush current  The inrush current begins when the Arms half cycle rises above the inrush threshold, and ends when the Arms half cycle rms is equal to or below the inrush threshold minus a user-selected hysteresis value. The measurement is the square root of the mean of the squared Arms half cycle values measured during the inrush duration. Each half-cycle interval is contiguous and non-overlapping as recommended by IEC 61000-4-30. Markers indicate inrush duration. Cursors allow measurement of peak Arms half cycle. 
 
General
Case 
Design  Rugged, shock proof with integrated protective holster 
Drip and dust proof  IP51 according to IEC60529 when used in tilt stand position 
Shock and Vibration  Shock 30 g, Vibration: 3 g Sinusoid, Random 0.03 g2/Hz according to MIL-PRF-28800F Class 2 
Display 
Type  Bright Full-Color LCD with CCFL backlight, 80cd/m2 
Size  115.2 x 86.4 mm (4.5 x 3.4 in) 
Resolution  320 x 240 pixels 
Contrast and brightness  User adjustable, temperature compensated 
Memory 
Screens  50 screen memories on Fluke 434 25 screen memories on Fluke 433 
Data  10 data memories for storing data including recordings on Fluke 434 5 data memories for storing data including recordings on Fluke 433 
Limit templates  2 preprogrammed, 2 administrator (programmable via FlukeView, 2 user locations) 
Real-time clock  Time and date stamp for AutoTrend, Transient display and SystemMonitor 
Size  256 x 169 x 64 mm (10 x 6.6 x 2.5 in.) 
Weight  2 kg (4.4 lb.) 
Mechanical
Line power  Switchable 115 V, 230 V adapter with country specific plug 
Battery power  Rechargeable NiMH (installed) 
Battery operating time  > 7 hours 
Battery charging time  4 hours 
Power saving  Adjustable time for dimmed backlight with on screen power indicator 
Power
Measurement methods used  IEC61000-4-30 class A 
Power Quality  EN50160 
Flicker  IEC 61000-4-15 
Harmonics  IEC 61000-4-7 
Standards
Compliance  IEC/EN61010-1 (2nd edition) pollution degree 2; CAN/CSA C22.2 No 101.1; ANSI/ISA S82.01 
Max voltage on banana input  CAT III 1000 V / CAT IV 600 V 
Max voltage on current BNC input  42 Vpeak 
Safety
Operating temperature  0 °C to +50 °C (32 °F to 122 °F) 
Storage temperature  -20 °C to +60 °C (-4 °F to 140 °F) 
Humidity  10 to 30 °C: 95 % RH non condensing (50 to 86 °F: 95 % RH non condensing) 30 to 40 °C: 75 % RH non condensing (86 to 104 °F: 75 % RH non condensing) 40 to 50 °C: 45 % RH non condensing (104 to 122 °F: 45 % RH non condensing) 
Maximum operating altitude  3000 m (9842 ft) Derate to CAT II 1000 V / CAT III 600 V / CAT IV 300 V above 2000 m (6561 ft) 
Maximum storage altitude  12 km (39,372 ft) 



For full Fluke 433 specifications, please click here: Fluke 433

Fluke 433 HandHeld Power Quality Analyzer

Includes (4) Fluke i400s AC Current Clamps, Hard Carrying Case & Accessories As Listed

Fluke 433 Fluke-433 Power Quality Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 16491

  • Fluke 433 Power Quality Analyzer (BC# 16491)
  • (4) Fluke i400s AC Current Clamps
  • (5) Fluke TLS430 Test Leads
  • (4) Fluke Alligator Clips
  • Fluke 433 Getting Started Guide
  • Fluke Power Quality Analyzer Software
  • AC Adapter/Charger
  • Strap For Unit
  • Hard Carrying Case