Fluke 729 30G FC Automatic Pressure Calibrator 30 psi / 2.0 bar

Fluke 729 30G FC Automatic Pressure Calibrator 30 psi / 2.0 bar

Fluke 744 kit with accessories

Fluke 744 Documenting Process Calibrator HART 275

Fluke 743B Documenting Process Calibrator 743

$2,259.00
Availability: In stock
SKU
2C01

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

The 743B does the work of several tools â?? sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device.


For documentation, the 743B automates calibration procedures and captures your data.
And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.
The 743B has a PC interface that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis. With its expanded memory, the 743B can hold a full week of calibrations and procedures.

The 743B is easy to use with flexible test strategies. And like all Fluke tools, it's rugged, reliable and tough as nails. It's like having several powerful tools in one - so you can work faster than ever:

  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Measure and source with one compact, rugged, reliable tool
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Bright white display. Read both sourced and measured parameters.
  • Multi lingual interface
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1msec.
  • Standard delivered with DPC/Track Sample software. Compatible with many Asset Management software packages.

Specifications:

Measurement Accuracy
Voltage DC
110.000 mV  0.025%+0.015% *
1.10000 V  0.025%+0.005% *
11.0000 V  0.025%+0.005% *
110.000 V  0.05%+0.005% *
300.00 V  0.05%+0.005% *
Voltage AC
20 to 40 Hz  2% + 10
40 to 500 Hz  0.5% + 5
500 to 1 kHz  2% + 10
1 kHz to 5 kHz  10% + 20
Ranges:  1.1000, 11.000, 110.00, 300V
Current DC
30.000 mA  0.01% + 0.015% *
110.00 mA  0.01% + 0.015% *
Resistance
11.000 O  0.05% + 50 mO
110.00 O  0.05% + 50 mO
1.1000 kO  0.05% + 500 mO
11.000 kO  0.1% + 10 O
Frequency
1.00 to 109.99 Hz  0.05 Hz
110.0 to 1099.9 Hz  0.5 Hz
1.100 to 10.999 kHz  5 Hz
11.00 to 50.00 kHz  50 Hz
Pressure
Accuracy  from 0.025% of range using any of 29 pressure modules.
 (for detailed specifications refer to pressure modules in options and accessories)
 Modules available for differential, gage, vacuum, absolute, dual and high pressure.
Note
*  (% of reading + % of full scale)

Source Accuracy
Voltage DC
110.000 mV  0.01%+0.005% *
1.10000 V  0.01%+0.005% *
15.0000 V  0.01%+0.005% *
Current DC
22.000 mA (Source)  0.01%+ 0.015% *
22.000 mA (Simulate)  0.02% + 0.03% *
Resistance
11.000 O  0.01% + 20 mO
110.00 O  0.01% + 40 mO
1.1000 kO  0.02% + 500 mO
11.000 kO  0.03% + 5O
Frequency
0.00 to 10.99 Hz  0.01 Hz
11.00 to 109.99 Hz  0.1 Hz
110.0 to 1099.9 Hz  0.1 Hz
1100 to 21999 Hz  2 Hz
22.000 to 50.000 kHz  5 Hz
Note
*  (% of reading + % of full scale)

RTDs and Thermocouples
Measure Accuracy:
10 O Cu (427):  2 °C
100 O Pt (3916):  0.3 °C
100 O Pt (3926):  0.3 °C
100 O Pt (385):  0.3 °C
200 O Pt (385):  0.3 °C
500 O Pt (385):  0.3 °C
1000 O Pt (385):  0.3 °C
120 O Ni (672):  0.3 °C
note:  For 2-and 3-wire measurement, add 0.4 °C
E:  0.3 °C
N:  0.5 °C
J:  0.3 °C
L:  0.3 °C
K:  0.3 °C
T:  0.3 °C
U:  0.3 °C
B:  0.9 °C
R:  1.0 °C
S:  0.9 °C
C:  0.6 °C
note:  Accuracy with external cold junction, for internal junction add 0.2 °C
Source Accuracy:
10 O Cu (427):  1 °C
100 O Pt (3916):  0.1°C
100 O Pt (3926):  0.1°C
100 O Pt (385):  0.1°C
200 O Pt (385):  0.1°C
500 O Pt (385):  0.1°C
1000 O Pt (385):  0.1°C
120 O Ni (672):  0.1°C
note:  For 2-and 3-wire simulation, add 0.4 °C
E:  0.2 °C
N:  0.3 °C
J:  0.2 °C
L:  0.2 °C
K:  0.3 °C
T:  0.3 °C
U:  0.3 °C
B:  0.8 °C
R:  0.9 °C
S:  0.9 °C
C:  0.6 °C
note:  Accuracy with external cold junction, for internal junction add 0.2 °C

Specifications
Data Log Functions
Measure functions:  Voltage, current, resistance, frequency, temperature, pressure
Reading rate:  1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length:  8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Rate:  4 steps/second
Trip detect:  Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage:  Selectable, 24 V or 28 V
Accuracy:  5%
Maximum current:  22 mA, short circuit protected
Maximum input voltage:  30 V DC
Step Functions
Source Functions  Voltage, current, resistance, frequency, temperature
Manual Step  Selectable step, change with arrow buttons
Autostep  Fully programmable for function, start delay, stepvalue, time per step, repeat

Environmental Specifications
Operating Temperature
 -10°C to +50°C
 -20°C to +50°C *
Storage Temperature
 -20°C to +60°C
Dust/water resistance
 Meets IP52, IEC 529
Operating Altitude
 2800 m
Note
*  Except frequency and AC

Safety Specifications
Agency Approvals
 CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993

Mechanical & General Specifications
Size
 130 x 236 x 61 mm
Weight
 1.4 kg
Batteries
NiCd:  7.2V, 1.7 Ah
Battery Life
 ~8 hours typical
Battery Replacement
 Via snap-shut door without opening calibrator; no tools required
Side port connections
 Pressure module connector
 RS-232 connector for PC interface cable
 Connection for optional battery eliminator
Data storage capacity
 1 week of calibration results
90 day specifications
 The standard specification intervals for the 743B is 1 and 2 years.
 Typical 90 day measurement and source accuracy can be estimated by
  dividing the one year "% of reading" or "%of output" specifications by 2.
 Floor specifications, expressed as "% of full scale" or
  "counts" or "ohms" remain constant.

 




For full Fluke 743B product specifications, please click here: Fluke 743B

Fluke 743B Documenting Process Calibrator

The 743B does the work of several tools – sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device.

Includes Carrying Case & Accessories As Listed

Fluke 743B Fluke-743B Process Calibrator Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 44985-L/T*

  • Fluke 743B Documenting Process Calibrator (BC# 44985-L/T*)
  • (2) 1000V Hard Point Test Leads
  • Fluke BC7217 Battery Charger
  • AC Adapter/Charger
  • RS232 PC Interface Cable
  • User Manual
  • Carrying Case (G)
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!