Alber CRT-300 kit with accessories

Alber Cellcorder CRT-300 Cell Resistance Tester

Anritsu S331D site masters with accessories

Lot Of 3 Anritsu S331D Cable Antenna Analyzer w/ Option 3 Color Screen

Fluke 80T-150U DMM Universal Temperature Probe

$0.00
Availability: Out of stock
SKU
10H08

Condition: Refurbished

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

 Fluke 80T-150U Universal Temperature Probe

The Model 80T-150U Universal Temperature Probe is a self contained temperature-to voltage converter. The probe is designed to provide a direct temperature reading when it is connected to any high impedance DMM that is capable of 1 mV resolution and at least a 300-count full scale readout capability. Output is l mV per degree (Celsius or Fahrenheit). Two switch-selected temperature output scalings are provided: -50 to +150°C or -58 to +302°F. Theprobe will stand off 60V dc or 30V ac rms (42.4V peak).

The unit is housed in two separate but attached assemblies: a temperature probe and a temperature-to-voltage converter. The probe contains the temperature-sensing element and is electrically connected to the temperature-to-voltage converter through a 46 inch shielded cable. A three-position switch on the converter acts as a power switch and is used for selecting Celsius or Fahrenheit scaling for the output. Two banana plugs with standard 0.75-inch spacing are provided for connecting the 80T-150U to the DMM.

Operating power for the 80T-150U is derived from a standard 9V battery. Typically, an alkaline battery provides more than 1600 hours of continuous operation before replacement is necessary. An OFF switch is provided on the temperature-to-voltage converter to allow battery conservation when the unit is not in use. In addition, the OFF position of the power switch allows the battery condition to be determined via the external DMM.

Temperature is measured by exposing the probe tip directly to the material to be measured (non-corrosive liquid, gas, or solid). A direct temperature reading is displayed on the DMM.

Specifications:
The 80T-150U will achieve rated accuracy when it is used with any 0.25% DMM that has an input impedance of = 1 M?.
Electrical
Measurement Range: -50 to +150 degrees Celsius
-58 to +302 degrees Fahrenheit
Accuracy:
AMBIENT °C ACCURACY
+15 to +35°C ± 1°C from 0 to +100°C, decreasing linearly to ±3°C at -50 and +150°C
0 to 15°C and +35 to +50°C ± 2°C from 0 to +100°C decreasing linearly to ±4°C at -50 and +150°C
AMBIENT °F ACCURACY
+59 to +95°F ± 1.8°F from +32 to +212°F, decreasing linearly to ±5.4°F at -58 and 302°F
+32 to +59 °F and +95 to +122 °F ± 3.6°F from +32 to +212°F, decreasing linearly to ±7.2 °F at -58 and 302°F
Sensitivity (80T-150U output): 1 mV dc / °C or °F
Voltage Standoff 60V dc or 30V ac rms (42.4V peak)
Settling Time: 5.5 seconds to settle within 2° for a 50° change
RF Field: Exposure to an RF field interferes significantly with this moduleメs capacity to accurately measure temperature. The interference is temporary and the module suffers no harm when exposed to an RF field of 3 V/m. Accurate temperature measurement capability is completely restored when the module is removed from the RF field.
Common sources of RF fields are handheld two-way radios and cellular telephones. If such a source is suspected of interfering with this module, either turn off the transmitter or increase the separation between the transmitter and the module.
Environmental
Ambient Operating Range for Temperature Module: 0 to +50°C (+32 to +122°F)
Maximum Temperature Probe Body and Cable: +70°C (160°F)
See Probe Limitations
Minimum Temperature Probe Body and Cable: Minimum Operating Temperature for Cable: -12°C (10°F)
Minimum Operating Temperature for Probe Body: -40°C
(-40°F) See Probe Limitations
Storage Temperature for Unit: -40 to +70°C (-40 to +160°F)
Humidity: 0% to 90% (0°C to 35°C)
0% to 70% (35°C to 50°C) (noncondensing)
Altitude: Operating: =10,000 feet
Storage: =50,000 feet
Application Force: 15 pounds maximum (probe tip to measured surface)
General
Weight: 5.7 ounces, 161.5 grams
Overall Length: 53.8 inches, 1.36 meters
Battery: Standard 9V battery (NEDA #1604,6F22,006P)
Battery Life: 1600+ hours, typical (Alkaline Battery), 6.5V minimum
Output Termination: Standard 0.75-inch spaced double banana plug
Probe Material: Glass-filled valox
Probe Size: 0.6" maximum diameter
Tip Material: Aluminum
Tip Size: 0/07" to 0.08" diameter, 30% convexed

Probe Limitations
The 80T-150U probe is constructed of a highly durable plastic and is suitable for measuring the temperature of liquids, gases, and solid surfaces up to 150°C. When measuring temperature, observe the following precautions to prevent damage to the probe:
  1. Do not expose the probe end (probe tip plus about 2 inches of the probe body) to temperatures exceeding +150°C (302°F). The remainder of the probe body should not be exposed to temperatures above +70°C (160°F)
  2. Do not expose the probe end (probe tip plus about 2 inches of the probe body) to temperatures below -50°C (-58°F). The remainder of the probe body should not be exposed to temperatures below -40°C (-40°F)
  3. For liquid measurements, recommended applications range from water, lubricants, and fuels to most solvents. Liquids as shallow as 1/2 inch can be measured since the temperature sensor is in the probe tip.

Fluke 80T-150U Universal Temperature Probe

The probe is designed to provide a direct temperature reading when it is connected to any high impedance DMM that is capable of 1 mV resolution and at least a 300-count full scale readout capability

80T 150U 80T150U

Fluke 80T-150U 80T150U Temperature Probe Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 25929

  • Fluke 80T-150U Universal Temperature Probe (BC# 25929)