Fluke 87 V kit with accessories

Fluke 87 V Industrial True RMS Digital Multimeter

Fluke 289 kit with accessories

Fluke 289 True RMS Industrial Digital Multimeter

Fluke 98 Automotive Dual Channel Scopemeter

$795.00
Availability: Out of stock
SKU
10H07

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

 Fluke 98 Automotive Scopemeter
Your new Fluke Automotive ScopeMeter® test tool is a powerful instrument with a wide variety of capabilities.
  • Its menu-driven interface has automatic configurations for most of your tests, so you will find that the test tool is easy to use.
  • Continuous AUTO RANGE, an exclusive Fluke feature, constantly acquires and displays the best possible signal.
  • The secondary ignition pickup and automated ignition functions make it easy for you to analyze an ignition system malfunction.
  • The Relative Compression mode helps you quickly find a low compression cylinder.
  • The Secondary Ignition Single function displays the waveform along with the spark voltage, RPM, burn time and burn voltage.
Many problems you will encounter are under a load - on a road test.
  • The Intermittent Record function can find and display such a problem. This record function can record up to 1280 divisions of continuous information.
  • The Flight Record function records screen snapshots from 200ms per division up to full time base speed.
  • The Plot Readings function allows you to plot up to four different readings of a signal over time with a single connection.
  • Min/Max Trendplot continuously monitors the minimum, maximum, and average value of a signal's readings with time stamp
Specifications:
Engine Tests
RPM 600 - 15,000 RPM, 1 RPM resolution <1000 RPM,
10 RPM resolution >1000 RPM
Dwell Range  Degree: 0 to 360°, 1° resolution
Milliseconds: 0 to 1,000 ms (1 ms resolution)
Percentage: 0% - 100%, resolution 3 digits
Timing Advance (TDC) in degrees (°) crankshaft rotation
Primary Voltage 0 to 300V
Secondary Voltage 0 to 80 kV
Burn Time  0.6 ms to 5 ms
Burn Voltage 0 to 80 kV
Relative Compression  0 to -100% contribution
Alternator Ripple Voltage 0 to 300V
Battery Condition Test 0 to 40V
Fuel Injection Pulse Width 0 to 1800 ms
Systems Automatically Tested: Saturated Driver
Conventional
Throttle Body Injection Systems
Current Controlled
Peak And Hold
Pulse Modulated
 
IGNITION TYPE PRIMARY SECONDARY
 
SINGLE PARADE PARADE PARADE
Conventional      X      X      X      X
DIS      X      X
Coil on Plug      X
 
Diesel Tests (with Optional DPS90 Diesel Probe Set)
Engine Speed 400 to 10,000 RPM
Advance (Diesel Pump Timing) in ° of crankshaft rotation
Injection Pulse  10 µs to 1200 ms

Automated Sensor Tests
The Sensors menu gives direct access to a wide variety of sensor measurements. The best operating mode is automatically selected. A few of the sensors tested automatically include:
  • Mass Air Flow Sensor (MAF)
  • Manifold Absolute Pressure (MAP)
  • Oxygen Sensor (Zirconium and Titanium)
  • Dual Oxygen Sensor
  • Temperature Sensors
  • Position Sensors
  • Camshaft Position
  • Exhaust Gas Recirculation (EGR)
  • Ride Height Sensors
  • Magnetic Sensors
  • Speed Sensors
  • Knock Sensors
  • Distributor Triggering
Air/fuel Systems Tested:
  • Mixture Control (Feedback)
  • Frequency Control Valve (CIS E)
  • Air Flow Meter
  • Idle Air Compensation
  • Exhaust Gas Recirculation (EGR)
Electrical System Tests
  • Battery Condition Test
  • Charging
  • Diode Test
  • Field Control
  • Ripple Voltage Measurement
  • Cranking
  • Voltage Reference And Ground
  • Voltage Drop
  • Clamping Diode
  • Solenoid Tests
  • Stepper Motor
Scope Mode
Continuous AutoRange
Hands-off signal probing. Continuously tracks input signals from 4 Hz to 5 MHz and automatically selects the proper time base, input range, trigger level, trigger slope, and trigger source.

40 ns Glitch detect
Sweep speeds 1 ms per division or slower
 
Vertical
Frequency Response, -3 dB DC to > 5 MHz
with Filter Adapter DC to > 2.5 kHz
AC coupled <10 Hz direct
Coupling AC, DC
Sensitivity 5 mV to 100 V/div
Modes A, -A, B, -B
Input Impedance 1 MO//55 pF direct, 10 MO//4 pF with Filter Adapter
Vertical Resolution 8 bit (256 levels)
Accuracy ± 2% +1 pixel)
Horizontal
Modes Recurrent, Single Shot, Roll
RANGES:
Recurrent 20 µs to 1 s/div
Dual input alternating 1 µs to 20 µs/div
Dual input chopped 50 µs to 1 s/div
Single Shot 1 µs to 200 ms/div
Roll 500 ms to 60 s/div
Dual input chopped  20 µs to 60 s/div
Accuracy  ±(0.1% + 1 pixel)
Record Length 512 samples (20 divisions)
Trigger
Sources A, B or TRIGGER (external)
Sensitivity: A or B <0.5 div to 1 MHz
<1.5 div to 5.5 MHz
Sensitivity: TRIGGER +0.2V and 2.0V (TTL level compatible)
External Input Impedance 1.5 M//40 pF direct
Delay Time -1 div

Cursor Measurements
Single input (INPUT A) cursor measurements:
Voltage at CURSOR 1.
Voltage at CURSOR 2.
Voltage difference (V) between the CURSOR 1 and CURSOR 2 positions.
Time difference (t) between the CURSOR 1 and CURSOR 2 positions.

Dual input cursor measurements:
Voltage at CURSOR 1 on the INPUT A signal waveform.
Voltage at CURSOR 1 on the INPUT B signal waveform.
Voltage at CURSOR 2 on the INPUT B signal waveform.
Voltage at CURSOR 2 on the INPUT A signal waveform.
Time difference (t) between the CURSOR 1 and CURSOR 2 positions

Meter Mode
Displays numeric reading and waveform of the signal on INPUT A.
Measurement readout: ............................... Absolute, relative (set zero function).
 
DC Voltage
Ranges direct input with STL90 leads ..... 100 mV, 300 mV, 1V, 3V, 10V, 30V, 100V, 300V
Accuracy ±(0.5% +5 counts)
Full Scale Reading 1000 or 3000 counts
Normal Mode Rejection >50 dB at 50 or 60 Hz
Common Mode Rejection >100 dB at DC, 50, 60, or 400 Hz
AC or AC+DC True RMS Voltage
Ranges
direct input

100 mV, 300 mV, 1V, 3V, 10V, 30V, 100V, 250V
Accuracy (valid from 5% range) 50 Hz to 60 Hz ±(1% +10 counts)
20 Hz to 20 kHz ±(2% +15 counts)
5 Hz to 1 MHz ±(3% +20 counts)
Full Scale Reading 1000 or 3000 counts
Crest Factor Automatic ranging on crest factor overload
Common Mode Rejection Ratio >60 dB, DC to 60 Hz
Frequency 1 Hz to 5 MHz
Resolution  4 digits
Accuracy ±(0.5% +2 counts)
RPM selectable: n pulses/720°
Range 600 RPM to 5,000 RPM
Resolution 4 digits
Accuracy ±(1% +5 counts)
Duty Cycle  positive or negative pulse
Range 2.0% to 98.0%
Accuracy (logic or pulse waveforms) ±(0.5% +2 counts)
Pulse Width  positive or negative pulse
Range 250 µs to 50 ms
Resolution 3 digits
Accuracy ±(0.5% +2 counts)
°C / °F Temperature for optional temperature probes
TR90: Range -50 °C to +200 °C (-58 to +392 °F)
Accuracy ±(1% +0.5 °C)
Other: Scaling 1 mV/degree
Amperes for optional current probes
Scaling 1 mV/A, 10 mV/A, 100 mV/A, 1 V/A (1 mV/mA)
Coupling DC, AC rms, or AC+DC rms
Range 2000A maximum
Resistance
Ranges 30O, 300O, 3 kO, 30 kO, 300 kO, 3 MO, 30 MO
Accuracy (300O to 30 MO) ±(0.5% +5 counts)
Accuracy (30O) ±(2.5% +25 counts)
Full Scale Reading 3000 counts
Measurement Current 500µA, 500 µA, 70 µA, 7 µA, 700 nA, 70 nA, 70 nA
Open Circuit Voltage <4V
Full Scale Voltage <250 mV to 3 MO, <2V to 30 MO
Diode Test
Open Circuit Voltage <4V
Full Scale voltage 2.800V
Measuring Current 0.5 mA
Measurement Modifying Functions
SMOOTH Moving average of readings up to last 8 seconds.
Fast Update Fast display update for IGNITION single cylinder test
FREEZE (HOLD) Holding of last stable reading on display
SET ZERO Zeros present reading as a reference value


Record Capabilities
Plot Readings
Plots up to 4 readings over time simultaneously.

Min Max Trendplot
Logs minimum, maximum, and average readings to memory at full accuracy and displays all three as graphs. Uses automatic vertical scaling and horizontal time compression for hands-off recording from a minimum of 60 seconds to a maximum 32 days full screen. The horizontal time compression process records data until the screen is full. Then it selects the greater maximum and the lesser minimum between each pair of readings. These readings are then compressed to fill half the screen. The process then repeats itself until up to 32 days have passed.

Intermittent Record
Monitors and records signal continuously for a full 128 screens (single channel) or 64 screens (dual channel) of data. Intermittent recording is initiated on entry and is terminated at any time by pressing any key on the instrument (except ON/OFF).Time base ranges 20 ms per division and slower (> 20 ms/division).

Flight Record
Records up to 40 successive screen snapshots in memory. Preserves the last 40 screens in an endless loop fashion. Time base ranges 200 ms per division and faster (< 200 ms/division).
 
Screen Memories (Save or Recall)
Memory 15 complete display screens including setup
Test Lead Calibration DC adjustment for 10:1 test leads only
General Specifications
Functional on These Engine Types:
Number of Cylinders 1, 2, 3, 4, 5, 6, 8
Engine Stroke 2 or 4 stroke
Fuel Types Gasoline, Diesel
Ignition Systems Conventional, DIS, Coil-on-Plug
Electrical System Voltages 6, 12, 24V
(Use gasoline settings for alternative fuel tests)
The accuracy of all measurements are within +(% of reading + number of counts)
from 18 °C to 28 °C. Add 0.1 x (specific accuracy) for each °C <18 °C or >28 °C.
Display
Type Foil Compensated Super Twisted Liquid Crystal
Size 84 x 84 mm (4.7" diagonal)
Resolution 240 x 240 pixels
Contrast User adjustable
Backlight Cold Cathode Fluorescent (CCFL) Tube
High Brightness 50 cd/m
External Power Requirements
Internal Battery Pack NiCad 4.8V nominal
Operating Time Typically 4 hours
Power Adapter/Battery Charger
Charging Time Typically 16 hours
Alternate battery 4 Alkaline C cells (non-rechargeable)
External Supply  8 to 20V DC, 5 W typical via 5 mm jack
Environmental
Temperature
Operating

0 °C to 50 °C
Storage -20 °C to 70 °C
Humidity
Operating 20 °C to 30 °C, 90% RH noncondensing
30 °C to 50 °C, 70% RH noncondensing
Storage 95% RH
Altitude
Operating 3 km (10,000ft)
Storage 12 km (40,000ft)
Shock and Vibration per MIL-T-28800 for Class 3


The Fluke 98 series including standard accessories, conforms with the EEC Directive 89/336 for EMI immunity, as defined by IEC 801-3, with the addition of the following tables (1 to 12)
Table 1
Susceptibility: no visible disturbance
Frequency range:
10 kHz - 25 MHz
E = < 0.1 V/m  E = 1 V/m  E = 3 V/m
Stand alone / with
STL90
5 mV/div - 100 V/div 5 mV/div - 100 V/div 5 mV/div - 100 V/div

Table 2
Susceptibility: no visible disturbance
Frequency range:
25 MHz ... 1 GHz
E = < 0.1 V/m E = 1 V/m E = 3 V/m
Stand alone 5 mV/div - 100 V/div 5 mV/div - 100 V/div 5 mV/div - 100 V/div
With STL90 5 mV/div - 100 V/div  200 mV/div - 100 V/div 500 mV/div-100 V/div

Table 3
Susceptibility: disturbance less than 10% of full scale
Frequency range:
25 MHz ... 1 GHz
E = < 0.1 V/m  E = 1 V/m  E = 3 V/m
Stand alone N/A N/A N/A
With STL90 N/A 50 mV/div - 100mV/div 100 mV/div - 200 mV/div

For conditions not specified in tables 1,2, and 3, a susceptibility effect of more than 10% is possible.

Multimeter Mode:

Table 4
Susceptibility: no visible disturbance
Frequency range:
10 kHz ... 25 MHz
E = < 0.1 V/m E = 1 V/m  E = 3 V/m
Stand alone / with
STL90
100 mV - 300V 100 mV - 300V 300 mV - 300V

Table 5
Susceptibility: no visible disturbance
Frequency range:
25 MHz ... 1 GHz
E = < 0.1 V/m  E = 1 V/m  E = 3 V/m
Stand alone 100 mV - 300V 100 mV - 300V 100 mV - 300V
With STL90 100 mV - 300V 100 mV - 300V  300 mV - 300V

Table 6
Susceptibility: disturbance less than 10% of full scale
Frequency range:
25 MHz ... 1 GHz
E = < 0.1 V/m  E = 1 V/m  E = 3 V/m
 
Stand alone N/A N/A N/A
With STL90 N/A N/A 100 mV


Automated Oxygen Sensor Test:

Table 7
Susceptibility: no visible disturbance
Frequency range:
10 kHz ... 25 MHz
E = < 0.1 V/m  E = 1 V/m E = 3 V/m
Stand alone / with
STL90 + filter
adapter
50 mV/div - 10 V/div 50 mV/div - 10 V/div  50 mV/div - 10 V/div


Table 8
Susceptibility: no visible disturbance
Frequency range:
25 MHz ... 1 GHz
E = < 0.1 V/m  E = 1 V/m  E = 3 V/m
Stand alone 50 mV/div - 10 V/div 50 mV/div - 10 V/div 50 mV/div - 10 V/div
With STL90 + filter
adapter
50 mV/div - 10 V/div 100 mV/div - 10 V/div 200 mV/div - 10 V/div

Table 9
Susceptibility: disturbance less than 10% of full scale
Frequency range:
25 MHz ... 1 GHz
E = < 0.1 V/m  E = 1 V/m E = 3 V/m
Stand alone N/A N/A N/A
With STL90 N/A 50 mV/div 100 mV/div

For conditions not specified in tables 7,8 , and 9, a susceptibility effect of more than 10% is possible.

Engine Test, ignition pattern: Secondary DIS:

Table 10
Susceptibility: no visible disturbance
Frequency range:
10 kHz ... 25 MHz
E = < 0.1 V/m E = 1 V/m  E = 3 V/m
Stand alone / with
PM9096/101
500 V/div - 20 kV/div 500 V/div - 20 kV/div 500 V/div - 20 kV/div

Table 11
Susceptibility: no visible disturbance
Frequency range:
25 MHz ... 1 GHz
E = < 0.1 V/m E = 1 V/m  E = 3 V/m
Stand alone 500 V/div - 20 kV/div 500 V/div - 20 kV/div 500 V/div - 20 kV/div
With PM9096/101 500 V/div - 20 kV/div 500 V/div - 20 kV/div  1 kV/div - 20 kV/div

Table 12
Susceptibility: disturbance less than 10% of full scale
Frequency range:
25 MHz ... 1 GHz
E = < 0.1 V/m E = 1 V/m E = 3 V/m
Stand alone N/A N/A N/A
With STL90 N/A N/A  500 V/div
Mechanical
Size exclusive holster 60 x 130m x 260 mm (2.4 x 5.1 x 10.2 inches)
Size inclusive holster 65 x 140 x 275 mm (2.5 x 5.5 x 10.8 inches)
Weight exclusive holster 1.5 kg (3.3 lbs)
Weight inclusive holster 1.8 kg (4.0 lbs)

Safety
Designed to Category III per IEC 1010 approved for 600V measurements on industrial power distribution systems.
Overload protection on INPUT A or INPUT B 300 Vrms
Overload protection on EXTernal input 300 Vrms
Surge Protection 4 kV
per IEC 664 and ANSI/IEEE C62.41 test method
Maximum Isolation to Earth 600 Vrms from any terminal
Optical Interface Optically Isolated to 600 Vrms

 

Fluke 98 Automotive Handheld Dual Channel Scopemeter

The Secondary Ignition Single function displays the waveform along with the spark voltage, 600 - 15,000 RPM, burn time and burn voltage.

Includes Carrying Case & Accessories As Listed Above!

Fluke 98 Fluke-98 Automotive Scopemeter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 31849-L/T*

  • Fluke 98 Automotive Scopemeter (BC# 31849-L/T*)
  • Fluke RPM90 Inductive Pickup
  • Fluke Coax To BNC Cable
  • Fluke Capacitive Secondary Pickup
  • Automotive Electronics 10X Auto Probe
  • Coax To Dual Clip Cable
  • BNC To Dual Ground Lead Cable
  • Fluke STL90 Test Lead Set Red
  • (2) Fluke Voltage Proibe Test Leads
  • (4) Fluke Alligator Clips
  • (2) Ground Leads
  • Fluke Flexible Test Lead
  • Accessory Case
  • AC Adapter/Charger
  • Hard Copy User Manual
  • Carrying Case (G)