 Fluke ESA615 Electrical Safety Analyzer
The ESA615 Electrical Safety Analyzer brings fast and simple automated testing to a portable analyzer for healthcare technology management professionals that perform electrical safety testing on medical equipment both in the field and in facilities. Whether it is simple testing or comprehensive analysis, the ESA615 can do it all. This multifaceted device performs all primary electrical safety tests, including line (mains) voltage, ground wire (protective earth) resistance, insulation resistance, device current, and lead (patient) leakage tests. It also offers ECG simulation and pointヨto-point voltage, leakage, and resistance tests. Versatile to global electrical safety standards of choice, ESA615 tests to ANSI/AAMI ES1, NFPA- 99, IEC62353 (VDE751) IEC60601-1 (2nd and 3rd editions) and AS/NZS 3551. The ESA615 is an allin-one solution with a multimeter, safety analyzer and ECG simulator in a single test instrument.

Automated: Pre-set templates allow you to test to the global standard of your choices at the push of a button. Let the unit guide you through the test steps quickly and accurately in three simple steps:
  1. Select the test sequence corresponding to your standard of choice
  2. Initiate the automated test sequence.
  3. Store the results on-board or wirelessly export to your PC in seconds.
It is that easy. The automated test sequences are easily customized to suit individual testing requirements.

Portable: The ESA615 is a small, lightweight analyzer with an integrated handle to carry from place to place for on-the-go field service. It is designed for operation in tight spaces, and is easy to fit on any cart. A light, protective carrying case makes it easy to store and transport.

Simple: A push-button interface allows quick access to highly-comprehensive functions and features, and an intuitive interface guides the user through tests. The ESA615 features a large display for clear indication of available functions, set-up criteria, device under test receptacle conditions, and test results. Data can be entered quickly with a plugヨand-play keyboard, barcode scanner and/ or on-board data entry interface. Data archival is fast and simple with wireless communication or through a removable memory card with capacity for thousands of test results.

Features:
  • On-board automation with automated test sequences for rapid testing and easy compliance to key global electrical safety standards (ANSI/AAMI ES1 (NFPA-99), IEC62353 (VDE751), IEC60601-1 2nd and 3rd editions, and AS/NZS 3551)
  • Portable, ergonomic design with an integrated handle and tilt stand
  • Human-factors-designed user interface for streamlined testing
  • ECG waveform tests and dual-lead measurements combine the functionality of a simulator, multimeter and safety analyzer in a single test tool
  • 20 A at 120 V current capability
  • Five applied parts jacks and easy ECG snap connection; optional expander box for up to 12-lead ECG testing
  • Easy data entry through barcode scanner, external keyboard or on-board keypad
  • Wireless communication plus removable memory card for fast and convenient data storage and exchange
  • Replaceable mains fuses keep your unit in the field and out of the repair shop
  • Custom language selections include English, French, German, Spanish, Italian and Portuguese
  • Large, easy-to-read display with adjustable contrast
  • Rigorously tested for rugged field applications, with CE and CSA in addition to Fluke qualityラruggedness for long-term reliability

Specifications:
Voltage
Range (mains voltage) 90 V ac rms to 132 V ac rms
Range (accessible voltage) 0 V ac rms to 300 V ac rms
Accuracy ± (2 % of reading + 0.2 V)
Voltage tests Mains and point to point
Earth resistance
Modes Two-Wire
Test current/Ranges/Accuracy > 200 mA ac / 0 O to 2 O / ± (2 % of reading + 0.015 O)
Resistance tests Earth resistance and point to point
Equipment current
Mode AC rms
Range/Accuracy 0 A to 20 A ± (5 % of reading + (2 counts or 0.2 A, whichever is greater))
Duty cycle 15 A to 20 A, 5 min. on/5 min. off
10 A to 15 A, 7 min. on/3 min. off
0 A to 10 A continuous
Leakage current
Modes
( Modes are available in all leakage tests with the exception of
MAP leakages that are available only in true-rms)
AC + DC (True rms)
AC only
DC only
Patient load selection (input impedance) AAMI ES1-1993
IEC 60601:
Crest factor = 3
Ranges 0 µA to 199.9 µA
200 µA to 1999 µA
2 mA to 10 mA
Frequency response/accuracy DC to 1 kHz / ± (1 % of reading + (1 µA or 1 LSB, whichever is greater))
1 kHz to 100 kHz / ± (2 % of reading + (1 µA or 1 LSB, whichever is greater))
1 kHz to 5 kHz (current > 1.6 mA) / ± (4 % of reading + (1 µA or 1 LSD, whichever is greater))
100 kHz to 1 MHz / ± (5 % of reading + (1 µA or 1 LSB, whichever is greater))
Accuracy for Isolation, MAP, Direct AP, Alternative AP, and Alternative Equipment leakage tests all ranges are: At 120 V ac + (2.5 µA or 1 LSD, whichever is greater) For Alternative equipment, Alternative AP, and Direct AP leakage tests, the leakage values are compensated for nominal mains as per 62353. Therefore, the accuracy specified for other leakages is not applicable.
Leakage tests Ground wire (earth)
Chassis (enclosure)
Lead to ground (patient)
Lead to lead (patient auxiliary)
Lead isolation (mains on applied part)
Direct equipment
Direct applied part
Alternative equipment
Alternative applied part
Point to point
Mains on applied part test voltage 100 % ± 7 % of Mains for AAMI, current limited to 1 mA ± 25 % per AAMI
100 % ± 7 % of Mains for IEC 62353 current limited to 3.5 mA ± 25 % per IEC 62353
100 % ± 7 % of Mains for IEC 60601-1 current limited to 7.5 mA ± 25 % per IEC 60601-1
Differential leakage
Ranges 75 µ A to 199 µA
200 µA to 1999 µA
2 mA to 20 mA
Accuracy ± (10 % of reading + (2 counts or 20 µA, whichever is greater))
Insulation resistance
Ranges/Accuracy 0.5 MO to 20 MO / ± (2 % of reading + 0.2 MO)
20 MO to 100 MO / ± (7.5 % of reading + 0.2 MO)
Source test voltage 500 V dc or 250 V dc
(+ 20 %, -0 %) 2.0 ± 0.25 mA short-circuit current
Insulation resistance tests Mains-PE, AP-PE, Mains-PE, Mains-NE (non-earthed accessible conductive part) and AP-NE (non-earthed accessible conductive part)
ECG performance waveforms
Accuracy ± 2 %
± 5 % for amplitude of 2 Hz Square wave only, fixed @ 1 mV Lead II configuration
Waveforms Rates:
ECG complex: 30 BPM, 60 BPM, 120 BPM, 180 BPM, and 240 BPM

Ventricular fibrillation:
Square wave (50 % duty cycle): 0.125 Hz and 2 Hz
Sine wave: 10 Hz, 40 Hz, 50 Hz, 60 Hz, and 100 Hz
Triangle wave: 2 Hz
Pulse (63 ms pulse width): 30 BPM and 60 BPM
Test standards
Available selections ANSI/AAMI ES-1, IEC62353, IEC60601-1, and AS/NZS 3551
Built-in test sequences
IEC60601-1 3rd Edition Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device, Generic Device and System
IEC62353 Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device and Generic Device
NFPA-99 (Hospital) Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device and Generic Device
ANSI/AAMI ES1 Patient Monitor, Defibrillator, Infusion Pump, Ultrasound Device and Generic Device
Communications
USB device upstream port Mini-B connector for control by a computer
USB host controller port Type A, 5 V output, 0.5 A max load. Connector for keyboard and barcode reader
Wireless IEEE 802.15.4 for control by a computer
Modes of operation Manual and remote
Power ratings
Mains voltage outlet 120 V ac
230 V ac
Mains voltage inlet power range 90 V ac rms to 132 V ac rms
180 V ac rms to 264 V ac rms
Maximum current 20 A
16 A
Hz 47 to 63 Hz
47 to 63 Hz
Environmental
Operating temperature 10 ºC to 40 ºC (50 ºF to 104 ºF)
Storage temperature -20 ºC to 60 ºC (-4 ºF to 140 ºF)
Operating humidity 10 % to 90 % non-condensing
Altitude 120 V ac mains supply voltage up to 5000 meters
230 V ac mains supply voltage up to 2000 meters


 
For full Fluke ESA615 product specifications, please click here: Fluke ESA615

Fluke ESA615 115 V ac Electrical Safety Analyzer

The ESA615 Electrical Safety Analyzer brings fast and simple automated testing to a portable analyzer for healthcare technology management professionals that perform electrical safety testing on medical equipment both in the field and in facilities

The ESA615 is an all-in-one solution with a multimeter, safety analyzer and ECG simulator in a single test instrument

Includes Carrying Case & Accessories As Listed

ESA-615 ESA 615

Fluke ESA615 ESA 615 Electrical Safety Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 45497-L/T*

  • Fluke ESA615 115 V ac Electrical Safety Analyzer (BC# 45497-L/T*)
  • (2) 1000V Hard Point Test Leads
  • Power Cord
  • USB PC Interface Cable
  • User Manual On CD-ROM
  • Carrying Case (G)