Fluke Simplifiber Pro SM MM Fiber Loss Test Kit

Fluke Simplifiber Pro SM MM Fiber Loss Test Kit

EXFO SPSB-C-300-54-74 SC-ST MM Fiber Launch Cable

EXFO SPSB-C-300-54-74 SC-ST MM Fiber Launch Cable

Fluke DSX-5000QOI SM MM OTDR OLTS Cat6a Cable Analyzer

$21,995.00
Availability: In stock
SKU
1H311

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

 Fluke Networks DSX-5000 Cable Analyzer
The DSX CableAnalyzer copper test solution enables testing and certification of twisted pair cabling for up to 10 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A or Class FA. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you?ll be. Unfortunately, there are a lot of things that slow the process down - setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers can not understand.

As part of the Versiv cabling certifcation product family, the DSX CableAnalyzer provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between profitabilty is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level V accuracy, making jobs easier to manage, and getting to system acceptance faster. It?s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Versiv Platform is Ready for Today's and Tomorow's Jobs
Electrically centered plug design is compliant with proposed ISO (IEC WG9 Standard IEC61935-1) Level V accuracy requirements to 1000 MHz with a future-ready design to support all hardware upgrades

The DSX-5000 CableAnalyzer enables cable testing and certification for 10 Gigabit Ethernet deployments - whether it is an existing Cat 5e, Cat 6, Cat 6A or Class FA cabling system, the DSX tests to all industry standards. The electrically centered test plug results in the Level V accuracy designation introduced with IEC to support field testing to Class FA, 1000 MHz. The DSX exceeds the IEC Level V specification with less than half the allowable crosstalk margin, assuring you of higher confidence in results over the full frequency range. Higher performance cabling systems like Cat 6A have less tolerance to interference and less noise margin in general. Additionally complex Alien Crosstalk link-to-link certification is simplified by integrating the measurement capability into each copper module for 10GBASE-T testing.

The DSX is the first field tester to support balance measurements including Transverse Conversion Loss (TCL) and Equal Level Transverse Conversion Transfer Loss (ELTCTL). TCL and ELTCTL are important measurements found in the cabling standards. They define a minimum performance for balance, the key parameter to help determine noise immunity. Industrial network owners/operators are especially interested in this property as it is a key parameter to help determine electromagnetic interference (EMI).

Fluke Networks' DSX-5000 CableAnalyzer meets the Intertek (ETL) Certification in accordance with the IEC-61935-1 specifications for accuracy Level IV, the draft accuracy Level V and in accordance with the ANSI/TIA-1152 specifications for Level IIIe.

ProjX Management System Manages Complex Jobs with Ease
Manage up to 12,000 test results with full graphics

Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and can be hard to manage. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the DSX- 5000 provides individual project files for all job specific details to be saved under a simple name. Eliminating the need to re-enter job specific details after starting a project. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job. In addition, it provides test results by cable ID, merges any changes without duplicates and always defaults to the last copper or fiber module installed. ProjX management system provides real time status to completion on each job with a 0-100% scale and gives the operator the option to isolate any test requiring a second look and helps to assure nothing is overlooked. The "Fix Later" selection creates a punch list or automatic to do list for correcting any workmanship. ProjX enables project managers and crew leaders to be truly efficient.

Taptive User Interface Simplifies Set Up, Eliminates Errors and Speeds Troubleshooting
Capacitive touchscreen allows quick tester setup and supports all standards

Taptive user interface is easy enough for even the newest technician to perform tests across multiple media types and testing requirements. The capacitive Taptive user interface makes all jobs easily accessible from the menu screen. Touch the job you?re working on and the large display confirms the test that needs to be performed, animated instructions simplify setting the tester configuration making correct testing assured.

Performs with Unsurpassed Speed
Ten second Cat 6A test time and the fastest way to submit your certification results

No tester offers so much speed for so many tests. Complete copper certification to Cat 6A in 10 seconds or certify two fibers at two wavelengths in both directions in just 3 seconds. Endorsed by cabling vendors worldwide assures that Versiv is the fastest way to project completion and system acceptance. Quickly get a Pass or Fail result and easily review individual test parameters by value or drill into specific area on a graph.

Troubleshoot Like an Expert
Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting

The DSX reduces the time required to fix cabling faults with Dedicated Diagnostics, a simple 1 button test runs all tests and saves all data. The graphical results screen allows you to look down the cable to see exactly where any cross talk, return loss or shield faults are happening on any given link. Previous testers had frequency limits of their diagnostic capabilities of up to 250 MHz only, but the DSX CableAnalyzer has no limitation. This common view is easily interpreted by novice and expert users alike to isolate and act on any failed results quickly and is stored with the test result for remote analysis.

Features:
  • Versiv enables users to accomplish more than ever with a cable tester, by accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time.
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of of technicians of all skill levels.
  • The DSX reduces the time required to fix cabling faults with Dedicated Diagnostics, a simple test that locates the problem

Performance:
  • Ten second Cat 6A test time contributes to the fastest way to gain certification
  • Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  • Manage up to 12,000 test results with full graphics
  • Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters

Standards:
  • Compliant with proposed ISO (IEC WG9 Standard IEC61935-1) Level V accuracy requirements to 1000 MHz
  • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) ? IEC61935-1 & 11801-1-4, IEEE 802.3af, IEEE 802.3at, ANSI/TIA/EIA-568-C.2
  • Next generation balance drafts ? IEEE 802.3, TIA TR42.7

Specifications:
Cable Types
Shielded and unshielded pair LAN cabling TIA Category 3, 4, 5, 5e, 6, 6A: 100 O ISO/IEC Class C, D, E, EA, F, and FA: 100 O and 120 O
Standard Link Interface Adapters
Permanent link adapters Plug type: shielded RJ45

Optional Plug type: Tera
Channel Adapters Jack type: shielded RJ45

Optional Jack type: Tera
Test Standards
TIA Category 3, 4, 5, 5e, 6, 6A per TIA 568-C.2
ISO/IEC    Class C and D, E, Ea, F, FA certification per ISO/IEC 11801:2002 and amendments
Maximum frequency 1200 MHz
General Specifications
Speed of Autotest Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Support test parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX-500 module and batery instaled: 2.625 in x 5.25 in x 1.0 in (6.67 cm x 13.3 cm x 27.94 cm)
Weight Main Versiv unit with DSX-500 module and batery instaled: 3 lbs, 5oz (1.28 kg)
Main unit and remote Lithium ion batery pack, 7.2 V
Typical batery life 8 hours
Charge time Tester of: 4 hours to charge from 10 % capacity to 90 % capacity
Languages supported English, French, German, Spanish, Portuguese, Italian, Japanese and Simplifed Chinese
Calibration Service center calibration period is 1 year
Environment Specifications
Operating Temperature 32° F to 113° F (0° C to 45° C)
Storage Temperature -4° F to +122° F (-20° C to +50° C)
Operating relative humidity (% RH without condensation) 0% to 90%, 32° F to 95° F (0° C to 35° C)

0% to 70%, 95° F to 113° F (35° C to 45 °C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2
Operating altitude 13,123 ft (4,000 m)
EMC EN 61326-1


Fluke Networks Certifiber Pro Optical Loss Test Set
Installing a high performance fiber optic cabling system starts with systems design and ends with systems acceptance. Certifying cabling to industry performance standards is a core element of the process. The faster it goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down - setting the tester up incorrectly, testing to the wrong limits, dirty fiber endfaces causing testing failures, waiting for lead technicians to analyze or troubleshoot failures, misinterpretation of results, and test reports that customers can't understand.

The CertiFiber Pro Optical Loss Test Set (OLTS) helps cabling professionals accomplish more than ever. It's all about accurate, error-free certification, making jobs easier to manage and certifying fiber optic cabling to industry standards, faster. CertiFiber Pro OLTS complies with all applicable cabling standards, which call out the new Encircled Flux launch condition requirements for optical sources. It's not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Features:
  • Versiv enables users to accomplish more than ever with a cable tester, accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • LinkWare Live allows you to manage results and the testing process from your smart devices.


Detailed View of Fiber Loss Results
View the results of each fiber tested at the same time and the Pass/Fail status on the test results screen. Easily identify the fiber type, test limits, loss and which fiber correlates to each result. All good results are highlighted with a green icon, any faulty events are highlighted with red icons and fibers are identified as output or input to facilitate quick identification and corrective action. The Taptive user interface also makes the results screen a powerful tool with a detailed window which can be touched to drill down and see detailed results.

Double Ended Fiber Optic Endface Certification
Fiber optic connector end-face contamination is a leading cause of fiber failures. Dirt and contaminants cause insertion loss and back-reflection that inhibit optical transmission and causes havoc with transceivers. Fiber loss testing can expose this problem, but in many cases, dirty connections make fiber testing time consuming and inaccurate. Since dirt can be an issue before, during, or after fiber optic certification testing, and migrate from one fiber optic connector end-face to another upon mating, both sides of any connection must always be cleaned and inspected.

CertiFiber Pro provides double ended fiber optic inspection capability through the use of 2 Versiv Main units. One unit acts as the normal CertiFiber Pro main and the 2nd unit functions as a Remote unit. Using a Main unit as a Remote provides a touchscreen interface at the remote end giving you the ability to visually inspect fiber endfaces!

CertiFiber Pro’s double ended fiber optic inspection capability allows you to inspect and certify fiber optic connector end-faces at both ends of your fiber link in less than a second so you can get your job done the first time. This double ended fiber optic inspection capability provides automated PASS/FAIL certification take the guess work out of fiber inspection so anyone can be a fiber expert.

Create, Manage and Select Projects
As part of the Versiv family, the CertiFiber Pro OLTS incorporates ProjX to ease job set-up, minimize test limit errors and better manage multiple projects. Project managers and technicians can create new projects for different jobs, locations or customers and or easily define project requirements for each job ahead of time – including all tests parameters and cable IDs – then keep track of job progress. All project detail information is stored in LinkWare for easy transfer to other Versiv cabling certification testers.

The ProjX management system allows project specifications to be loaded and saved into the tester ahead of time. As the tester moves from job to job, the project list is easily accessible and users can quickly see detail data such as percentage of links tested, percentage to completion and percentage of results exported.

Dynamic Project and User Profile Management
CertiFiber Pro increases efficiency by allowing field technicians access to project based settings entered at the time of set-up. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job more. Setting limits and establishing cable ID sets is easy with the Taptive user interface. And once the technicians start testing, the progress of each project is easily monitored.

ProjX™ Management System specific benefits are: Real time status to completion on each job 0-100%, giving the operator the “Fix Later” option to isolate any test requiring a second look and helps to assure nothing is overlooked. The "Fix Later" selection creates a punch list or automatic "to do" list for correcting any workmanship issues.

Managing the testing of multiple jobs with multiple teams, testers, and requirements is time consuming and can be hard to manage. Increasingly larger jobs make project organization more important than ever. The new ProjX management system on the CertiFiber Pro assigns a name for all job specifics. This eliminates the need to ever have to re-enter test limits or other job details after starting a project or returning to it after a different job. This minimizes set-up errors or lost files when switching from one job to another or utilizing multiple testers on a single job, enabling project managers and crew leaders to be more efficient.

Specifications:
Power Meter Specifications
Input Connector Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector Type InGaAs
Wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty < +/- 5% +/- 32 pW
Measurement Linearity < ± 0.1 dB
Loss/Length Specifications
Specification CertiFiber Pro Multimode Modules CertiFiber Pro Singlemode Modules
Testing Speeds (excludes referencing times) Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection)
Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Input/Output Connectors Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Launch Condition Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
Fiber Types Tested 50/125 µm or 62.5/125 µm singlemode
Source Type and Wavelengths LED source 850 nm ± 30 nm 1300 nm ± 20 nm Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm
Maximum Length Measurement 12 km 130 km
Length Measurement Accuracy ± 1.5 m plus ± 1 % of length
Output Power (Nominal) ≥ -24 dBm with EF-TRC ≥ -4 dBm
Output Power Stability ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes ± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes
Source Wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty < +/- 5% +/- 32 pW
Measurement Linearity < ± 0.1 dB
Visual Fault Locator (VFL)
Output Power Requirement
Output Power >-5 dBm
<0 dBm
SMF-28 singlemode fiber
Continuous wave
SC/UPC connector
Operating Wavelength 650 nm nominal
Output Modes Continuous wave
Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector Adapter 2.5 mm universal
Laser Safety Class II CDRH
Over operating temperature range
Environmental Specifications
Operating Temperature 0 °F to 113° F (-18° C to 45° C)
Storage Temperature -22° F to 140° F (-30° C to +60° C)
Operating Relative Humidity (% RH without condensation) 0% to 90%, 32° F to 95° F (0° C to 35° C)
0% to 70%, 95 °F to 113 °F (35° C to 45° C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapters
Safety CSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2
Pollution Degree 2
Altitude Operating: 4,000 m; storage: 12,000 m
EMC EN 61326–1




Fluke Networks OptiFiber Pro OTDR Module

Designed for Enterprise Fiber
As enterprise networks and datacenter architectures evolve, IT infrastructure administrators demand better OTDR technology to maintain fiber network performance. Many OTDRs (Optical Time Domain Reflectometers) used for fiber troubleshooting are designed for carriers and contain cumbersome and complicated features that enterprise users don’t need. Few OTDRs are built with features and usability for enterprise network engineers, SAN designers and cable installers.

As enterprises consume more storage resources and adopt higher bandwidth (40G, 100G) datacenter architectures, the resilience of the cabling infrastructure becomes highly dependent upon maintenance tools to ensure fiber reliability. OptiFiber Pro is the industry’s first purposebuilt OTDR that meets the unique challenges of an enterprise fiber infrastructure. With its simple Taptive user interface and powerful feature set, the OptiFiber Pro turns anyone into an efficient and expert premise fiber troubleshooter or installer.

Unique Features:
  • SmartLoop OTDR enables automated testing and analysis of two fibers in a single test. Not only does this halve network-testing time, but it also eliminates the need to travel to the far end of the connection to perform tests.
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of of technicians of all skill levels.
  • LinkWare management software provides unmatched analysis of test results and professional test reports
Performance:
  • Test times as short as two seconds in Quick Test mode
  • Quickly test datacenter fiber with pre-programmed settings
  • Troubleshoot datacenter fiber links with short patch cables and many connectors because of ultra short dead zones
  • Easily characterize all connectors, splices and areas of high loss with graphical EventMap™ view
  • ProjX management system increases return on investment by enabling OTDR project sharing among users and different jobs
  • Reduce network downtime by quickly and precisely identifying faults on all fiber types
  • Built-in Visual Fault Locator (VFL) easily identifies damaged fibers.
Standards:
  • Full OTDR capability that certifies fiber performance based on industry standards or customer specifications
  • Compliant with ISO and TIA standards
Unique Certification with Flexibility and Efficiency
An important aspect in maximizing an OTDR’s value is to properly plan its day-to-day usage. With ProjX management system, OptiFiber Pro allows a project manager to define each user’s role, settings and the associated tasks to be performed – transforming the OTDR into an all-in-one fiber testing tool complete with planning, inspection, certification and reporting.

Advantages:
  • Powerful ProjX management system facilitates OTDR sharing with clear job assignment for each operator
  • Easy monitoring of job progress with pass/fail results
  • Built-in Visual Fault Locator (VFL) to facilitate troubleshooting
  • On-screen report generation and upload to LinkWare™ application
Taptive User Interface
Most OTDRs are designed for a myriad of applications, causing the user interface to be difficult to navigate and interpret. OptiFiber Pro has the Taptive user interface which combines the latest “gesture-based” interface technology with a capacitive touchscreen to deliver the most innovative and user-friendly OTDR.

Extremely short event and attenuation dead zone
The OptiFiber Pro leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.5 m typical for MM and 3.6 m typical for SM) of any OTDR. This technological advancement allows OptiFiber Pro to detect and measure closely spaced faults where no other OTDR can in today’s connector-rich datacenter and storage area network environments.

Two second trace per wavelength
Another breakthrough with OptiFiber Pro is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap event, Table or Trace. The end result is less time spent testing and more time performing other tasks.

DataCenter OTDR™ Mode
With a simple one-touch selection, users enter DataCenter OTDR mode – without setup time for fine tuning as needed in legacy OTDRs. DataCenter OTDR mode automatically detects OTDR parameters – enddetection algorithms, pulse widths – without getting confused by the short links or number of connectors.

Graphical EventMap™ view
To eliminate the learning curve associated with reading an OTDR trace, OptiFiber Pro’s advance logic automatically interprets the information to create a detailed and graphical map of events that includes connectors, splices and anomalies. To accommodate different preferences, users can easily switch between the EventMap, the Event Table and the Trace for test details. Any faulty events will be highlighted with RED icons to facilitate quick troubleshooting.

On-screen “help” suggests corrective action(s) for resolving fiber problems during each testing step. The “help” offered is context sensitive which allows users to quickly pinpoint possible resolutions. An easy-toread, gray icon in the bottom, left-hand corner shows detailed corrective action recommendations.

Dynamic project and user profile management with ProjX management system
OptiFiber Pro enhances job efficiency by allowing the project manager to create and manage operator and job profiles per project. Defined jobs or sets of cable IDs can be assigned to specific operators. The progress and status of each project can also be easily monitored.

SmartLoop OTDR
SmartLoop OTDR enables automated testing and analysis of two fibers in a single test. This patent pending process automatically separates the two fibers for individual pass/fail analysis, display, and reporting. Not only does this cut the testing time by at least half, it also enables bi-directional testing without moving the OTDR to the far end. In addition to getting the job done quicker, SmartLoop OTDR further enhances the ease and speed of testing in environments where the far end is difficult of even dangerous to reach because the OTDR never has to be moved to the far end.


Specifications:
Quad OTDR Module Specifications
Wavelengths 850 nm +/- 10 nm, 1300 nm +35/-15 nm, 1310 nm +/- 25 nm, 1550 nm +/- 30 nm
Compatible fiber types 50/125 μm, 62.5/125 μm, Singlemode
Event dead zone 850 nm: 0.5 m (typical), 1300 nm: 0.7 m (typical)
1310 nm: 0.6 m (typical), 1550 nm: 0.6 m (typical)
Attenuation dead zone 850 nm: 2.5 m (typical), 1300 nm: 4.5 m (typical)
 1310 nm: 3.6 m (typical), 1550 nm: 3.7 m (typical)
Dynamic range 850 nm: 28 dB (typical), 1300 nm: 30 dB (typical)
 1310 nm: 32 dB (typical), 1550 nm: 30 dB (typical)
Max distance range setting MM: 40 km, SM: 130 km
Distance measurement range 850 nm: 9 km, 1300 nm: 35 km, 1310 nm: 80 km
1550 nm: 130 km
Reflectance range 850 nm: -14 dB to -57 dB (typical), 1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical), 1550 nm: -14 dB to -65 dB (typical)
Sample resolution 3 cm to 400 cm
Pulse widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns, 1300 nm: 3, 5, 20, 40, 200, 1000 ns, 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test time (per wavelength) Auto setting: MM - 5 sec (typical) SM – 10 sec (typical)
Quick test setting: MM – 2 sec (typical) SM – 5 sec (typical)
Best resolution setting: MM – 2 to 180 sec SM – 5 to 180 sec
FaultMap setting: MM – 2 sec (typical) MM – 180 sec (max) SM – 10 sec (typical) SM – 180 sec (max)
DataCenter OTDR setting: MM – 1 sec (typical at 850 nm) MM – 7 sec (max) SM – 20 sec (typical) SM – 40 sec (max)
Manual setting: MM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
VFL Specifications
On/Off control Mechanical switch and a button on the touch screen
Output power 316 µW (-5 dBm) ≤ peak power ≤ 1.0 mW (0 dBm)
Operating wavelength 650 nm nominal
Spectral width (RMS) ±3 nm
Output modes Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter 2.5mm universal
Laser safety (classification) Class II CDRH Complies to EN 60825-2
General specifications
Weight Mainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
Dimensions Mainframe with module and battery: 2.625 in x 5.25 in x 11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
Battery Lithium ion battery pack, 7.2 volts
Battery life 8 hr Auto OTDR operation, dual wavelength no video probe connected, 150 m of fiber
Operating temperature -18ºC to 45ºC
Non-operating temperature -30ºC to 60ºC
Operating altitude 4,000 m (13,123 ft), 3,200 m (10,500 ft) with AC adapter
Storage altitude 12,000 m
EMC EN 61326-1




For full Fluke Networks DSX-5000QOI specifications, please click here: Fluke Networks DSX-5000QOI

Fluke Networks Versiv Mainframe w/ 
Fluke Networks Versiv Remote w/
Set Of Fluke Networks DSX-5000 Cat6a Cable Analyzer Modules w/
Set Of Fluke Networks CFP-QUAD Certifiber Pro SM MM OLTS Fiber Loss Test Set Modules w/
Fluke Networks OFP-QUAD OptiFiber Pro SM MM Quad Fiber OTDR Module
&
Fluke Networks FI-1000 Fiber Inspection Probe

The DSX-5000 Is The Newest Cable Analyzer From Fluke That Replaces The DTX-1800 Cable Analyzer!

Dynamic Range:
850 / 1300 nm : 28 / 30 dB
1310 / 1550 nm : 32 / 30 dB

This Kit Includes The Fluke Networks VERSIV-ADP-WIFI Adapter for connecting wirelessly to Fluke Network's LinkWare Live

Test & Certify Cat5, Cat5e, Cat6 & Cat6a Cabling Installations up to 1 GHz!

CertiFiber Pro OLTS complies with all applicable cabling standards, which call out the new Encircled Flux launch condition requirements for optical sources

Includes Carrying Case & Accessories As Listed

DSX 5000 DSX5000 DSX-5000 CFP-QUAD CFP QUAD CFPQUAD OFPQUAD OFP QUAD

Fluke Networks DSX-5000QOI SM MM OLTS Cat6a Cable Analyzer DSX5000QOI SM MM OLTS Cat6a Cable Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry

BC# 6644A-L/T* 6644B-L/T* 33546-L/T* 33547-L/T* 33544-L/T* 33545-L/T* 33447-L/T* 17500M-L/T*

  • Fluke Networks Versiv Mainframe (BC# 6644A-L/T*)
  • Fluke Networks Versiv Remote (BC# 6644B-L/T*)
  • (2) Fluke Networks DSX-5000 Cat6a Cable Analyzer Modules (BC# 33546-L/T* 33547-L/T*)
  • (2) Fluke Networks CFP-QUAD Certifiber Pro SM MM OLTS Modules (BC# 33544-L/T* 33545-L/T*)
    • SM Source:
      • 1310nm
      • 1550nm
    • MM Source:
      • 850nm
      • 1300nm
  • Fluke Networks OFP-QUAD OptiFiber Pro SingleMode MultiMode Quad OTDR Module (BC# 33447-L/T*)
    • MM OTDR Source:
      • 850nm
      • 1300nm
    • SM OTDR Source:
      • 1310nm
      • 1550nm
    • VFL
  • Fluke Networks FI-1000 Fiber Inspection Probe (BC# 17500M-L/T*)
    • U125 Tip For Probe
    • FS Tip For Probe
    • U25 Tip for Probe
    • LC Tip For Probe
  • (2) Fluke Networks DSX-PLA004 Link Adapters
  • (2) Fluke Networks DSX-CHA004 Channel Adapters
  • Fluke Networks VERSIV-ADP-WIFI Adapter
  • (2) Termination Plugs
  • (2) Earbuds
  • (2) SM SC-SC Fiber Cables
  • (2) MM SC-SC 50 Micron Fiber Cables
  • (2) Fluke Networks MMC-50-SCLC Fiber Cables
  • (2) Fluke Networks SMC-9-SCLC Fiber Cables
  • (2) RJ11/45 Universal Adapters
  • IBC Brand Cleaner 2.5mm
  • IBC Brand Cleaner 1.25mm
  • Fluke Networks LinkWare Software v9.2
  • (2) AC Adapter/Charger
  • (2) Power Cord
  • USB PC Interface Cable
  • User Manual On Cd-ROM
  • (2) Straps For Units
  • Carrying Case w/ Strap
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!