The Fiber Optic Power Meter (FOM) measures optical power on fiber optic cables. It indicates any power loss on tested cables using any digital multimeter (DMM) or graphical multimeter (GMM) that has a 10 MW input impedance, standard diameter banana jacks, and mVdc capability. The Fiber Optic Light Source (FOS) is used as a light source with the FOM or other fiber optic meters.
General Specifications
Power Meter Specifications
Output: | 1 mV per 1 dB |
Input Connector Type: | Fixed ST |
Photodetector Type: | Germanium |
Application Range: | 800 to 1600 nm |
Calibrated wavelengths: | 850, 1300, and 1550 nm |
Acceptable fiber types (sizes): | 9/125 to 100/140 mm |
Operating range: | +3 to -50 dBm |
Maximum power level: | +5 dBm |
Absolute accuracy: | ±0.25 dB, (Specified at 25°C & -10.0 dBm per NIST standard) |
Relative accuracy: | ±0.15 dB, (Specified over any 10 dB within measurement range) |
Repeatability: | ±0.04 dB |
Battery type: | 9V alkaline, NEDA 1604A or IEC 6LR61 |
Battery life: | 16 hours minimum, 100 hours typical, 9V alkaline |
Low battery indication: | Blinking LED indicator |
Operating temperature: | 0 to +40°C |
Storage temperature: | -20 to +70°C |
Humidity: | 0 to 40°C, up to 75% RH |
Electromagnetic Compatibility: RF Field £1 V/m RF Field = 3 V/m |
Total Accuracy = Specified Accuracy Specified Accuracy + 2.5 dB |
Source (850/1300) Specifications
Type: | Infrared LED |
Wavelength: | 850/1300 ± 30 nm, -40/+50 nm |
Output power: | -20 dBm, nominal into 62.5/125 micron multimode fiber |
Output connector type: | Fixed ST |
Beam divergence: | 0.3 radians |
Pulse duration: | Continuous wave |
Maximum output: | 200 mW (radiated into free space) |
Stability: | ±0.2 dB per 8 hours at 20°C after 20 minute warmup |
Temperature coefficient: | -0.08 dB per °C, < 18°C or > 28°C |
Battery type: | 9V alkaline, NEDA 1604A or IEC 6LR61 |
Battery life: | 16 hours minimum, 24 hours typical, 9V alkaline |
Low battery indication: | Blinking LED indicator |
Operating temperature: | 0 to +40°C |
Storage temperature: | -20 to +70°C |
Humidity: | 0 to 40°C, up to 75% RH |
For full Fluke Networks FOS FOM product specifications, please click here: Fluke Networks FOS FOM
Fluke Networks FOM & FOS Multimode Fiber Test Kit
FOM Fiber Optic Meter:
850nm
1300nm
1550nm
FOS 850/1300 Fiber Optic Source:
850nm
1300nm
Includes Hard Carrying Case and Accessories As Listed!
Fluke Networks FOM FOS FOM-FOS MM Fiber Loss Test Set Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
- Fluke FOM Fiber Optic Meter:
- 850nm
- 1300nm
- 1550nm
- Fluke FOS 850/1300 Multimode Fiber Optic Source:
- 850nm
- 1300nm
- (2) MM ST - ST Fiber Cables
- ST - ST Fiber Connector
- User Manual on CD-ROM
- Hard Carrying Case