Hioki Clamp On 3169-20 Power Tester
CLAMP ON POWER HiTESTERs are 3169-20 and 3169-21 that allow measurement of single-phase to three-phase 4-wire circuits with a single unit. In addition to measuring standard parameters such as voltage, current, power, power factor, and integrated values, these clamp-on power meters can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurements. The two new power meters also feature PC card data storage, and come equipped with an RS-232C interface for PC communications. Further, with greater data processing speeds, it is possible to measure the power of just a few cycles, enabling more detailed and effective energy-saving measures for equipment. The 3169-20 and 3169-21 are ideal for users who want to achieve close control over energy-saving management activities and measures.


Features:

  • Measure power lines of up to four systems (with a common voltage)
  • A wide range of measurement functions
  • Equipped with ranges from 0.5 A to 5000 A
  • Supports high-speed data storage from individual waveforms
  • PC Card compatible plus internal hard drive for extra memory
  • Housed in a compact A5 body size
  • Multi-language Compatibility
  • Detect incorrect connection using vector diagrams
  • Polarity display and measurement using the reactive power measurement method
  • High-speed D/A output
  • Ideal for power and harmonics management


Range Configuration Table:

 
CLAMP ON SENSOR 9661
 (5A, 10A, 50A, 100A, 500A)
Connection 5.0000A 10.000A 50.000A 100.00A 500.00A


150.00V
Single-phase 2-wire 750.00 W 1.5000kW 7.5000kW 15.000kW 75.000kW
Single-phase 3-wire
1.5000kW

3.0000kW

15.000kW

30.000kW

150.00kW
Three-phase 3-wire
Three-phase 4-wire 2.2500kW 4.5000kW 22.500kW 45.000kW 225.00kW


300.00V
Single-phase 2-wire 1.5000kW 3.0000kW 15.000kW 30.000kW 150.00kW
Single-phase 3-wire
3.0000kW

6.0000kW

30.000kW

60.000kW

300.00kW
Three-phase 3-wire
Three-phase 4-wire 4.5000kW 9.0000kW 45.000kW 90.000kW 450.00kW


600.00V
Single-phase 2-wire 3.0000kW 6.0000kW 30.000kW 60.000kW 300.00kW
Single-phase 3-wire
6.0000kW

12.000kW

60.000kW

120.00kW

600.00kW
Three-phase 3-wire
Three-phase 4-wire 9.0000kW 18.000kW 90.000kW 180.00kW 900.00kW
 
FLEXIBLE CLAMP ON SENSOR 9667 Connection 500.00 A 5.0000kA


150.00V
 
Single-phase 2-wire 75.000kW 750.00kW
Single-phase 3-wire
150.00kW

1.5000MW
Three-phase 3-wire
Three-phase 4-wire 225.00kW 2.2500MW


300.00V
Single-phase 2-wire 150.00kW 1.5000MW
Single-phase 3-wire
300.00kW

3.0000MW
Three-phase 3-wire
Three-phase 4-wire 450.00kW 4.5000MW


600.00V
Single-phase 2-wire 300.00kW 3.0000MW
Single-phase 3-wire
600.00kW

6.0000MW
Three-phase 3-wire
Three-phase 4-wire 900.00kW 9.0000MW



Specifications:
Basic Specifications:
Measurement line type Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and three-phase 4-wire systems (50/60 Hz)
Number of systems that can be measured (for systems that share the same voltage) Single-phase: 1P2W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 systems
 1P3W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 systems
 Three-phase: 3P3W2M (measures the voltage and current for two lines) . . . . . . 2 systems
 3P3W3M (measures the voltage and current for all three lines) . . . 1 system
 3P4W (measures the voltage and current for three lines) . . . . . . . . 1 system
 3P4W4I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 system
Item Voltage, current, active power, reactive power, apparent power, power factor, integrated value, frequency, harmonics
Measurement range For the voltage, current, and active power ranges, see the range configuration tables
Measurement method : Simultaneous digital sampling of voltage and current, PLL synchronization or a fixed clock (50/60 Hz)
Input methods Voltage: Isolated input Current: Isolated input using a clamp-on sensor
Effective measurement area Within 5 to 110% of the range
Total display area Voltage and current: Within 0.4 to 130% of the range
 (zero is suppressed for less than 0.4%)
 Power: Within 0 to 130% of the range
 (zero is suppressed when the voltage or current is zero)
Harmonic level: Within 0 to 130% of the range
Display 5.7-inch LCD (320 × 240 dots), with backlight
Range switching method Manual (the current range can be set for each system)
Display update rate Approx. every 0.5 seconds
 (except when using a PC card while accessing the internal memory, or when performing RS-232C communications)
Input resistance (50/60 Hz) Voltage: 2.0 M? ± 10% (differential input)
 Current: 200 k? ± 10%
Maximum input Voltage input: 780 Vrms AC, peak value: 1103 V
 Current input: 1.7 Vrms AC, peak value: 2.4 V
Maximum rated voltage to earth Voltage input terminals: 600 Vrms AC (50/60 Hz)
Crest factor Voltage: Less than 2 (for full-scale input)
 Current: Less than 4 (for full-scale input. However, less than 2 for the 500 A, 1 kA, and 5 kA ranges)
Internal memory capacity 1MB
 
Display Specifications
Instantaneous value display Voltage, current, active power, reactive power, apparent power,
power factor, frequency, average voltage, average current, (average
values are for each system)
Average value display Voltage, current, active power, reactive power, apparent power,
power factor, frequency, average voltage, average current
Maximum/minimum
value display
Voltage, current, active power, reactive power, apparent power,
power factor, frequency
Integrate display Integrated value
Active power (consumption/regeneration)
Reactive power (lag/lead)
Demand volume display
(Integrated value within
the specified interval)
Integrated value
 Active power volume (consumption/regeneration)
 Reactive power volume (lag/lead)
Demand value display
(average value within
the specified interval)
Active power (consumption), reactive power (lag), power factor
Maximum demand value display
(average value within the
maximum specified interval)
The maximum demand value since the beginning of time series
measurement and the time and date it occurred.
Harmonics list List of the items measured for the specified harmonic (numerical
value).
Harmonics graph Bar graph or vector diagram of the items measured for the specified
harmonic
Waveform display Voltage and current waveforms (with a magnification update
function)
Measurement value
enlargement display
Select and enlarge up to 5 items from the instantaneous value
display.
 
Measurement Specifications
Measurement method True RMS method
Measurement display Measurement of three voltage lines and 3 or 4 current lines is possible
when using three-phase 3-wire and three-phase 4-wire systems
Measurement display For three-phase 3-wire (the 3P3W3M setting), refer to the display for
phase power values.
Polarity display For consumption: no symbol, for regeneration: "-"
[Reactive power measurement]
Using the reactive
 ON: Measures the reactive power directly using the reactive power
measurement method
 OFF: Calculates the reactive power from the measurement values for
voltage, current, and active power
Polarity display For lag phase (LAG : current is slower than voltage): no symbol
 For lead phase (LEAD: current is faster than voltage) : "-"
 (Reactive power measurement method "ON")
[Apparent power measurement]
Polarity display
No polarity
[Power factor measurement]
Measurement range
1.0000 (lead) to 0.0000 to +1.0000 (lag)
For lag phase (LAG: current is slower than voltage) :no symbol
 For lead phase (LEAD: current is faster than voltage) : "-"
Measurement range 40.000 to 70.000 Hz
Input area for guaranteed accuracy Within 10 to 110% of the range (for sine wave input)
Measurement source  Voltage U1
Measurement range 40.000 to 70.000 Hz
Input area for guaranteed accuracy Within 10 to 110% of the range (for sine wave input)
Measurement source Voltage U1
[Integrated measurement]
Measurement range
Active power : 0.00000 mWh to 99999.9 GWh consumption
 -0.00000 mWh to -99999.9 GWh regeneration
 Reactive power : 0.00000 mvarh to 99999.9 Gvarh lag
 -0.00000 mvarh to -99999.9 Gvarh lead
Measurement display Active power : Displays consumption and regeneration separately
 Reactive power : Displays lag and lead separately
[Harmonic measurement]
Measurement range
Basic wave frequency: 45 to 66 Hz
 PLL synchronization
Order for analysis Up to the 40th order
Window width A single cycle (number of data points analyzed: 128 points)
Window type Rectangular
Analysis rate 1/16 cycles
Item for analysis Harmonic level: The voltage, current, or power level for each harmonic order
: Harmonic content percentage: The voltage, current, or power
 content percentage for each harmonic order
: Harmonic phase angle: The voltage, current, or power phase
 angle for each harmonic order
: Total value: The total value for voltage, current, or
 power up to the 40th harmo
 
Setting Specifications
Measurement line settings 1P2W, 1P3W, 3P3W2M, 3P3W3M, 3P4W, 3P4W4I
Clamp-on sensor settings 9694, 9660, 9661, 9667, 9669, 9695-02 and 9695-03 (* A different sensor can be set for each system.)
VT (PT) and CT ratio settings 0.01 to 9999.99 (* A different CT ratio can be set for each system.)
Measurement start method Manual or time (year, month, day, hour, minute)
Measurement stop method Manual, time, or timer (1 seconds to 8784 hours)
Output Interval Standard or fast (*Maximum measurement period: 1 year)
 Standard interval: 1, 2, 5, 10, 15, or 30 seconds, or 1, 2, 5, 10, 15, 30,
or 60 minutes
 Fast interval: A single waveform, or 0.1, 0.2, or 0.5 seconds
Data output destination PC card, internal memory, or printer
File name Automatically attached, or set the desired name (up to 8 alphanumeric characters)
Display averaging circuit OFF, 2, 5, 10, 20 times (for movement averaging)
Screen copy destination PC card, internal memory, or printer
Display language settings Japanese, English, German, French, Italian, Chinese (Simple, Trad),
Spanish , Korean
Other settings Reactive power measurement method selection, harmonic distortion
selection, order display selection, backlight settings, ID settings,
clock settings, etc.
Copy file Copies files from the internal memory to the PC card
Load/Save selected file  Loads/Saves the file(s) selected from the internal memory or PC card
Delete file Deletes the file(s) from the PC card
Format Initializes the PC card or internal memory.
Storage format Measurement data: CSV format
(binary format when using the fast interval setting)
 Waveform data: Binary format
 Screen data: BMP format
 Settings data: CSV format
Instantaneous values Voltage, current, active power, reactive power, apparent power,
power factor, frequency, average voltage, average current, (average
values are for each system)
Average value Voltage, current, active power, reactive power, apparent power,
power factor, frequency, average voltage, average current, (average
values are for each system)
Maximum/minimum value Voltage, current, active power, reactive power, apparent power,
power factor, frequency
Integrated value Active power (consumption/regeneration)
 Reactive power (lag/lead)
Demand value Active power (consumption), reactive power (lag), power factor
Maximum demand value The maximum demand value since the beginning of time series
measurement and the time and date it occurred.
Harmonic : Each harmonic order (level, content percentage, and phase angle),
total value, instantaneous value for THD-F/THD-R
: Each harmonic order (level, content percentage, and phase angle),
total value, average value for THD-F/THD-R for each interval
: Each harmonic order (level, content percentage, and phase angle),
total value, maximum/minimum value for THD-F/THD-R within
each interval
Waveform Waveform (Voltage or current)
Status information Exceeds the voltage/current crest factor, PLL unlock, power failure,
exceeds the display limit
Numerical values Prints the data selected as the data output item (during time series
measurement).
Waveform Hard copy of the screen (printing of each interval not available)
 
General Specifications
Operating environment Indoors, up to 2000m(78.74ft) ASL
Operating temperature and humidity 0 to 40°C, 80% RH or less (non-condensating)
Storage temperature and humidity -10    to    50°C,    80%    RH    or    less    (non-condensating)
Withstand voltage  (50/60 Hz for 15 sec.) 5.55 kVrms AC: Between the voltage input terminal and the 3169
casing
 3.32 kVrms AC: Between the voltage input terminal and the
current input terminal/external interface terminal
 2.3 kVrms AC: Between the power supply and the 3169 casing
 1.39 kVrms AC: Between the power supply and the current input
terminal/external interface terminal
Power supply voltage rating 100 to 240 V AC, 50/60 Hz
Maximum rated power 30 VA
Dimensions and weight Approx.210(8.27?)W × 160(6.30?) H × 60D(2.36?) mm (excluding
protrusions),
Approx.1.2 kg(42.3oz.) (3169-20, 3169-21)
Conforming standards Safety
 EN61010
 Pollution degree 2,
                    measurement    category    ?    (anticipated    transient    overvoltage    6000V)
: EMC
 EN61326
 EN61000 - 3 - 2, EN61000 - 3 - 3






For full Hioki 3169 product specifications, please click here: Hioki 3169

Hioki 3169 Clamp On Power HiTester Power Quality Analyzer

In addition to measuring standard parameters such as voltage, current, power, power factor, and integrated values, these clamp-on power meters can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurements

Ideal For Power and Harmonics Management

Includes (4) Hioki 9669 Clamp-On Sensors, Hard Carrying Case & Accessories As Listed 

3169-20

 

BC# 29373-L/T*

  • Hioki 3169-20 Clamp On Power HiTester (BC# 29373-L/T*) 
  • (4) Hioki 9661 Clamp-On Sensors
  • (4) Hoioki Test Leads
  • Hioki 32MB Flash Card w/ Adapter
  • Power Cord
  • User Manual On Cd-ROM
  • Carrying Case (G)
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!