Fluke NetTool kit with accessories

Fluke NetTool 10/100 Network Connectivity Tester

EXFO BRT-320A kit with accessories

EXFO BRT-320A Fiber Optic Back-Reflection Meter

WWG JDSU OLS-15 OLP-18C SM Fiber Loss Test Set

$0.00
Availability: Out of stock
SKU
4P66

Condition: Refurbished

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

OLS-15 Laser Source

  • Optimized for field measurements on single-mode systems
  • TWINtest: Simultaneous measurement of attenuation at 1310 and 1550 nm
  • Auto-l mode for automatic wavelength detection on the power meter
  • Fiber identification using modulated signals
  • Universal interchangeable adapter system
  • Rugged, shockproof and splashproof housing
  • AC, dry- or rechargeable battery operation

Optimized for field measurements on single-mode systems
During installation testing and maintenance work on all sorts of single-mode fiber optical systems (e.g. long-distance telecom systems, passive optical networks for FITL applications), a highly stable output power level is required along with a wide dynamic range (attenuation measurements). To obtain the desired degree of measurement accuracy, a light source is needed on the transmit end which can launch sufficient optical power into the fiber. With their -7 dBm output power level, the OLS-15 Optical Laser Source is ideal for these applications. In conjunction with the OLP-15 Optical Power Meter, they provide features which greatly simplify installation, maintenance and troubleshooting/ repair of these systems. OLS-15 is a dual-wavelength source for 1310 and 1550 nm with a common output for both wavelengths.

TWINtest: Simultaneous measurement of attenuation at 1310 and 1550 nm
With its common output for both wavelengths, the OLS-15 dualwavelength source can transmit signals at 1310 and 1550 nm in alternation (TWINtest mode). The OLP-15 meter can then detect and evaluate these signals at the correct wavelength. This makes it very easy to characterize a device under test (DUT) at both wavelengths in a single step.

Auto-? mode for automatic wavelength detection on the power meter
All of the OLS sources include the Auto-l mode; an identifier is transmitted to indicate the current wavelength. On the receiving end, the OLP-15 reads the wavelength identifier and automatically switches to the proper wavelength. Erroneous measurements can be avoided using this mode; fiber identification is another possibility.

Fiber identification using modulated signals
If the sources are used with a meter such as the OLP-10 (in place of the OLP-15) or another industry-standard fiber identifier, the output signal can be modulated at 270 Hz, 1 kHz or 2 kHz. The modulation frequency is then detected and displayed on the receiving end.

Universal interchangeable adapter system
The universal adapter system handles the common fiber optical connector systems, such as FC, SC and DIN. The internal connector is also easily accessible for inspection and cleaning. A dustcap is included to protect the optical connector.

Rugged, shockproof and splashproof housing
The laser sources have a form-fitted, shockproof and splashproof housing which provides the mechanical ruggedness needed to handle tough conditions in the field. The membrane keypad is waterproof. A fold-out stand is provided on the back of the sources.

Battery or a.c. power
The laser sources can be powered with dry batteries or NiCd cells. They can be operated for typ. 28 h on dry batteries or typ. 9 h on NiCd cells (i.e. more than one workday). When a separate AC adapter is used, the instrument can be AC powered and NiCd batteries fitted in the instrument can also be recharged.

Specifications

Optical source type Dual FP laser
Wavelength 1310+20 nm / 1550 +20 nm
FWHM spectral width < 5 nm/ < 5 nm
Output power (CW)
into 9/125 µm fiber
-7 dBm (class 1 laser as per IEC 825)
Total output power uncertainty
in range -10 to +50 8C, incl. connector error
+1 dB
Output signal stability
(valid for CW and modulated signals)
Short-term (15 min, -10 to +50 °C, =+0.3 K)
Long-term (8 h, -10 to +50 °C, =+3 K)
+0.02 dB typ.
+0.2 dB

Modes
CW
TWINtest

AUTO ?
FMOD
Output level reduction
in TWINtest mode, AUTO ? and FMOD

continuous wave output signal
alternating output signal with 1310 and 1550 nm identifiers
(OLS-15 only)
output signal has 1310 or 1550 nm identifier
square-wave modulation (270 Hz, 1 kHz or 2 kHz, selectable)

3 dB
Optical connector
Interchangeable test adapters
BN 2060/00.xx adapter
e.g. DIN, FC, SC
General specifications
Power supply
Dry batteries/NiCds
Operating time, dry batteries / NiCds
Battery/NiCd power saving

A.C. line operation
Battery charging

Electromagnetic compatibility
Ambient temperature
Nominal range of use
Storage and transport
Dimensions (w6h6d) in mm
Weight (including batteries/NiCds)
26Mignon (AA size), 1.5 V / 26Mignon (AA size), 1.2 V
typ. 28 h / typ. 9 h
The instrument switches off automatically after approx. 20 min.
to avoid discharging the batteries (function can be disabled)
separate a.c. adapter unit NT-20
externally with charger unit,
internally using NT-20
as per EN 50 081-1, 50 082-1 (CE conformance)

±10 to +55 °C
±40 to +70 °C
approx. 956496195
approx. 500 g

OLP-18C High Performance Optical Power Meter

The OLP-18C is a compact, high performance optical power meter for installation, maintenance and repair in fiber optic networks. They can be used on their own for simple system power measurements, or with a light source for insertion lossmeasurements.

The full functionality of the high performance OLP range is realized when used with an Acterna Optical Light Source (OLS).

Together with a variable optical attenuator the OLPs are the right instruments for the commissioning of optical transmission systems, for example: DWDM systems.

Highlights

  • Easy report generation with FiberASSISTANT software
  • Data storage and RS-232 interface
  • Rugged, impact resistant, splash-proof
  • Three year recalibration period
  • High precision, easily exchangeable adapter including UPP

High performance measurement
High performance OLPs feature a wide dynamic range making them suitable for use in many different applications. The OLP-18C is designed for those with high power levels such as CATV systems, optical amplifiers and DWDM systems.

Precision calibration to traceable national standards ensures high accuracymeasurement in user selectable units. Two unique Universal Push Pull (UPP) adapters provide reliable, reproducible connection to all common 1.25 and 2.5 mm connectors, ensuring the user always has the correct connection in the field.

Absolute power level can be stored with a single keystroke, making it easy to take relative loss test measurements.

AutoWavelength Detection and TwinTest
Used with an Acterna Optical Light Source (OLS), high performance OLPs feature two powerful functions, designed to avoid the possibility of measurement errors.

The AutoWavelength Detection function detects the actualwavelength being used and switches automatically to the appropriate wavelength range. TwinTest performs two wavelength loss measurements automatically.

Automatic identification of individual fibers
High performance OLPs can be used to detect the modulation frequency of the fiber to be measured, for identification purposes. To speed this process, an audible signal identifying the fiber as one of four standard frequencies sounds as soon as the fiber is brought near the input.

Data storage
High performance OLPs can store up to 1000 sets of testmeasurements. Data can be downloaded to a printer for hard copy records, or to a PC for long-term storage and further analysis using Acterna?s FiberASSISTANT PC software.

Rugged field instrumentation
OLP-18C features low power consumption for long battery life. It can be operated with AC, dry or rechargeable AA batteries which can be changed in the field very easily. The unit is supplied in a robust housing, with splashproof foil keypad and protectors for the optical connectors, to ensure reliable operation even in harsh field conditions.

Specifications

Wavelength range 800 to 1700 nm
Photodiode filtered InGaAs
Fiber type 9/125 to 50/125 µm
Standard wavelengths, switchable
850, 980, 1310, 1480, 1510, 1550, 1625 nm
Display range -60 to +26 dBm
Max. permitted level + 26 dBm
Intrinsic uncertainty ±0.13 dB (±3%)
Overall measurement uncertainty
For the level range -50 to +23 dBm
850nm ±0.33 dB ±10 nW
1300, 1310 nm ±0.25 dB ±2 nW
1550 nm ±0.25 dB ±2 nW
1625 nm ±0.5 dB ±2 nW
Wavelength detection
automatic switching and display of nominal wavelength
Fiber detection automatic display of line ID
Data memory 1000 measurement results
Data readout/remote control RS-232 interface

Display
Modulation detection
270Hz, 330 Hz, 1 kHz, 2k Hz
Result display LCD, 4 digit
Results displayed in dBm, dB, mW, µW
Resolution 0.01 dB/0.001 µW
Backlight function switchable via separate key
Reference level
transfer of measured value or entry of any reference level in the range ?80 to +30 dBm, storage of one reference value per wavelength
Optical connector interchangeable adapter interchangeable adapter from the BN 2014/00.X range suitable for measurements on flat or angled physical contact systems
e.g. 2.5 mm plugs: FC, ST, SC, DIN, E2000, SMA,?
e.g. 1.25 mm plugs: LC,MU-Adapter
BN 2014/00.28 and many more
Power supply
Dry batteries x Mignon (AA) 1.5 V
Or NiCd rechargeable cells 2 x Mignon (AA) 1.2 V
Operating time
from batteries typically 36 h
NiCd cells typically 12 h
Batteries/NiCd power saving
the instrument switches off automatically after approx. 20 min (function can be disabled)
AC line operation (OLP-1xC) separate AC adapter
Electromagnetic compatibility
corresponds to EN 50081-1 and EN 50082-1
(CE conformance)
Recommended calibration interval 3 years
Ambient temperature
Nominal range of use -10°C to +55°C
Storage and transport -40°C to +70°C
Dimensions (w x h x d) Approx. 95 x 49 x 185 mm
Weight Approx. 500 g



For full JDSU OLP-18C product specifications, please click here: JDSU OLP-18C
WWG JDSU Singlemode 1310nm 1550nm Loss Test Set
OLS-15 Laser Source & OLP-18C High Performance Optical Power Meter

Source
1310nm
1550nm

Power Meter
850nm
980nm
1310nm
1480nm
1510nm
1550nm
1625nm

JDSU OLS-15 OLP-18C OLS15 OLP18C SM Fiber Loss Test Set Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.