Datacom LANCat 1500 kit with accessories

Datacom LANcat 1500 LAN Cable & Activity Tester

Tektronix Fiber kit with accessories

Tektronix SM MM Fiber Test Kit

JDSU Acterna SM MM Fiber Loss Test Set

$0.00
Availability: Out of stock
SKU
4P03

Condition: Refurbished

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

JDSU OLS-6
Pocket-sized dual wavelength light sources, 1310 and 1550 nm

  • Pocket class: Rugged, compact and lightweight
  • Easy-to-use, straight forward operation
  • Reliable basic functionality for most economical testing
  • Three year calibration period
  • OLS-6: dedicated for single mode at 1310 and 1550 nm
  • Standard AA batteries or NiMH/NiCd cells
  • FTTx ready

The JDSU OLS-6 pocket-sized light sources are the result of JDSU's many years of experience in optical measurement technology. They are designed for dual wavelength measurement alongside JDSU's pocket-sized or Smart optical power meters.

The rugged OLS-6 is really pocket-sized and fit into a handy belt bag so they are always ready to use. The simple three-button operation together with an easy-to-read display makes them extremely easy-to-use.

The OLS-6 is designed for dual wavelength measurement in various single mode applications. It has separate optical laser ports for each wavelength (1310 nm and 1550 nm, 1490 nm and 1550 nm, or 1550 nm and 1625 nm). Together with an JDSU optical power meter (OLP) the automatic wave-length detection guarantees fast and error-free results.

The 1625 nm wavelength of the OLS-6 allows additional tests for detection of micro/macro-bending effects at optical fibers. This makes it ideal for dense wavelength division multiplexing (DWDM) applications.

The OLS-6 with 1490/1550 nm is specially designed for tests in FTTx applications.

Specifications

Functions

Details for 1310 and 1550 nm

Emitter Type

Dual FP Laser (laser class 1)

Wavelength Range 1310 nm ± 20 nm
1550 nm ± 20 nm
Spectral width (RMS) typically <5 nm
Output level (CW)
9/125 µm fiber -7 dBm  typically ± 1 dB
Modulated output level typically -10 dBm
Level stability (Short-term)
1 h, -10 to +55°C typically ± 0.03 dB
Level stability (Long-term)
8 h, -10 to +55°C maximum ± 0.25 dB
Modulated output signal (Rectangular, modulation ratio 1:1);
Selectable 270 Hz, 1 kHz, 2 kHz
Modes
CW continuous wave signal
Auto-? output signal includes ? information (detectable by all JDSU power meters)
FMOD modulation for fiber identification 270 Hz, 1 kHz, 2 kHz
Dual Both wavelengths activated
Optical connector Two outputs (one for each wavelength) each with the same connector (to be selected when ordering) FC/PC, SC/PC

JDSU OLS-5
Pocket-sized dual wavelength light sources, 850 - 1300 nm

  • Pocket class: Rugged, compact and lightweight
  • Easy-to-use, straight forward operation
  • Reliable basic functionality for most economical testing
  • Three year calibration period
  • Dedicated for multimode at 850 and 1300 nm
  • Standard AA batteries or NiMH/NiCd cells
  • FTTx ready

The JDSU OLS-5 pocket-sized light sources are the result of JDSUメs many years of experience in optical measurement technology. They are designed for dual wavelength measurement alongside JDSUメs pocket-sized or Smart optical power meters.

The rugged OLS-5 is really pocket-sized and fit into a handy belt bag so they are always ready to use. The simple three-button operation together with an easy-to-read display makes them extremely easy-to-use.

For multimode applications the OLS-5 is the ideal choice. Via one single port 850 and 1300 nm LEDs are connected to the test cable. Together with an JDSU optical power meter (OLP) automatic wavelength detection and TwinTest guarantee fast and error-free results at a high test speed.

Specifications

Emitter Type

LED (laser class 1)
Wavelength Range 850 nm ± 20 nm
1300 nm ± 50 nm
Spectral width (FWHM) 850nm
1300 nm
Output level (CW) 50/125 µm fiber -20 dBm ± 1.7 dB
62.5/125 µm fiber -17 dBm ± 3 dB
100/140 µm fiber -13 dBm ± 3 dB
9/125 µm fiber -40 dBm ± 3 dB
Modulated output level 3 dB less than in CW mode
Level stability
(short-term)
15 min, +23°C ±3 K,
?T = ± 0.5 K
± 0.25 dB
15 min, -10 to +55°C,
?T = ± 0.5 K
± 0.08 dB
Level stability
(Long-term)
15 min, +23°C ±3 K,
?T = ± 0.5 K
± 0.25 dB
15 min, -10 to +55°C,
?T = ± 0.5 K
± 0.08 dB
Modulated output signal
(Rectangular, modulation ratio 1:1);
Selectable
1 kHz, 2 kHz
Modes CW continuous wave signal
Auto-? output signal includes ? information
(detectable by all JDSU power meters)
FMOD modulation for fiber identification 270 Hz, 1 kHz, 2 kHz
TWINTest Automatic toggling between 850 nm and 1300 nm
Fixed optical connector ST

JDSU OLP8
The JDSU OLP8 was designed for the installation and maintenance of singlemode and multimode cables, systems, and networks

The JDSU OLP product line of pocket-sized optical power meters provides an excellent price/performance ratio for universal, singlemode loss test and systems power measurements.

Highlights

  • TWINtest cuts test time in half and simplifies handling due to automatic attenuation measurements at 850/1300 nm or 1310/1550 nm.
  • Auto-lambda automatic wavelength detection and simple fiber identification together with an JDSU OLS light source.
  • Easy three-button operation lets you concentrate on your work at hand.
  • Lightweight, portable, rugged, and shock-proof design guarantees long life.
  • Includes a handy nylon belt pouch.

Applications

  • The OLP-6 is the universal solution for telecommunications applications with a dynamic range of -65 to +10 dBm.
  • The OLP-8 is the solution for the measurement of high optical power values in the range of -50 to +23 dBm.

Key Features

  • Extra long battery lifetime (>130 hours).
  • Battery replacement indicator.
  • Powered from standard dry batteries or rechargeable cells.

Specifications

Display range

-50 to +23 dBm

Max. permitted input level +23 dBm 
Accuracy
Intrinsic uncertainty ± 0.20 dB (± 5%)
Linearity ± 0.06 dB (-35 to +20 dBm)
Wavelength range 780 to 1650 nm
Standard wavelength settings 980, 1310, 1480, 1550 nm
Wavelength and modulation detection
together with OLS-5, OLS-6, OLS-55/56,
OLT-55
270 Hz, 330 Hz, 1 kHz, 2 kHz
1310, 1550 nm -35 to +23 dBm
980 nm -30 to +23 dBm
Connectable
fiber types
9/125 µm to 10/125 µm

Includes:

  • JDSU OLP-8 Optical Power Meter
    • 980nm
    • 1310nm
    • 1480nm
    • 1550nm
  • Acterna OLS-6 Optical Laser Source
    • 1310nm
    • 1550nm
  • JDSU OLS-5 Optical LED Source
    • 850nm
    • 1300nm
  • Fiber Cables
    • (2) MM ST-ST
    • (2) SM SC-ST
  • SC-SC Fiber Connector
  • (2) Industrial Alkaline Batteries
  • User Manuals On CD-ROM 
  • Hard Carrying Case



For full JDSU OLS-6 product specifications, please click here: JDSU OLS-6
JDSU Singlemode & Multimode Fiber Optic Loss Test Set
JDSU OLP-8 Optical Power Meter, Acterna OLS-6 Optical Laser Source & JDSU OLS-5 Optical LED Source

JDSU OLP-8 Optical Power Meter
980nm
1310nm
1480nm
1550nm

JDSU OLS-6 Optical Light Source
1310nm
1550nm

JDSU OLS-5 Optical Light Source
850nm
1300nm