EXFO FTB-1 Fiber Optic OTDR Mainframe

EXFO FTB-1 Fiber Optic OTDR Mainframe

ODM AC 050B MTP Straight Adapter Tip 4 VIS 300

ODM AC 050B MTP Straight Adapter Tip 4 VIS 300

ODM DLS355 DLS350 RP460 SM MM Fiber Loss Test Kit

$0.00
Availability: Out of stock
SKU
DM24

Condition: Refurbished

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

ODM DLS 350 & 355 Dual Laser Source

The DLS 350 and DLS 355 Dual light sources from ODM represent the latest stabilized light sources for accurate loss measurements on either multimode or singlemode systems. No longer is it necessary to carry separate devices for each wavelength of measurement. Significant test time improvements are realized by using these rugged dual wavelength sources. Used in conjunction with the RP 400 series power meters, loss measurements according to EIA/TIA standards are provided.

The DLS 350/DLS 355 dual light sources also provide a 2 kHz tone output for fiber identification when used with the RP 400 series power meters. The incoming 2KHz signal is identified and an audible alert is provided by the RP 400 series power meter. The 2KHz tone provided by the DLS 350 and 355 may also be used with non invasive fiber identifier devices such as the LFI 110 Live Fiber Identifier from ODM.

Connection to the device under test DUT, is by the male SC connector output allowing for easy cleaning of the connector surface. Please contact ODM for hybrid adapters to accommodate different connector styles. These dual sources are provided with a long lasting battery or may be factory configured for optional AC operation.

Features:
  • Dual wavelength single output 
  • DLS 355 Dual Laser 1310nm, 1550nm Singlemode application
  • 2kHz Tone output
  • NIST traceable 
  • Long battery life
  • Rugged, smallest and most affordable

Specifications:

Wavelength
DLS355 DLS 350
1310nm & 1550nm Laser 850nm & 1300nm LED
Output power - 4.0 dBm Typ. - 20dBm Typ.
Laser Classification Class 1 (FDA 21 CFR 1040, 11) NA
Output stability +/- 0.05dB, one hour
+/- .03dB long term after 15 minute warm-up
Spectral Width 5nm/5nm 40nm/120nm
Tone Output 2kHz
Power on Push button ON, Auto shutoff
Battery CR 2 , Optional AC power for long term
Dimensions 6.1x.94x.75 in. (15.5x2.38x1.90cm)
Weight 3.0 oz (8.5g)
Operating Temperature -10 to 50°C
Storage Temperature -30 to 60°C


ODM RP460 Optical Power Meter
The RP 450, RP 455 and RP 460 Optical Power Meters measure optical power on fiber optic networks operating at 850nm, 1310nm, 1490 and 1550nm. These easy to use optical power meters provide absolute dBm or dB loss measurements on all optical networks. The RP 450 allows the user to set the incoming signal to a â??zeroâ?? reference providing direct loss measurements. The RP 455 provides set ref and storage of up to 1000 measurements per wavelength. The RP 460 provides these features plus the ability to transfer data via the mini USB port to a laptop computer. The RP 455 & 460 also allows a â??scroll featureâ?? to review field measurements.

The RP 450, RP 455 and RP 460 provide an audible alert when the incoming signal is a modulated 2kHz tone. The companion TP 200, DLS 300 series LED or laser sources or any external 2kHz optical source may generate this incoming tone. This feature is very useful for quick fiber identification at the field location.

Use the RP 450, RP 455 or RP 460 to check the output at the patch panel or wall outlet in the premise, telecom or broadband market. Connection to the fiber under test is made via the universal 2.5 mm adapter. Additional male or female connector adapter styles are available. The readily available CR 2 battery provides over 1000 operations for the power meter. A LO BAT display alerts the user to replace the battery.

Features:
  • 850, 1310, 1490, 1550nm
  • Set ref, Zero function, Store and download 1000 measurements via USB to a computer
  • Audible tone alert from incoming 2kHz signal 
  • Accepts all connector styles
  • NIST traceable measurements
  • Multimode or Singlemode application
  • Long battery life
  • Rugged and compact size

Specifications:
Wavelength range 850nm to 1625nm
Resolution 0.01dB
Absolute accuracy +/- 0.25dB
Optical interface Universal 2.5mm
Tone identification 2kHz Incoming signal, Audible Alert
Power on Push button ON, Auto shutoff
Storage Store up to 1000 measurements per wavelength
Data transfer Mini USB Port (1000 points/wavelength)
Dimensions 6.1x.94x.75 in. (15.5x2.38x1.90cm)
Weight 3.0 oz (8.5g)

DLS 355 Singlemode 1310 / 1550nm Laser Source w/
DLS 350 Multimode 850 / 1300nm LED Source
&
RP 460 Singlemode Multimode Fiber Optic Power Meter

Power Meter:
- 850nm
- 1310nm
- 1490nm
- 1550nm

Includes Hard Carrying Case & Accessories As Listed

RP-460 DLS-355 DLS-350 RP 460 DLS 355 DSL 350

ODM DLS 355 DLS 350 RP 460 DLS355 DLS350 RP460 Fiber Loss Test Kit Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 17574M 17575M 17577M

  • ODM DLS355 Dual SingleMode Laser Source (BC# 17575M)
    • SM Source:
      • 1310nm
      • 1550nm
    • SC Connector For Source
  • ODM DLS350 Dual MultiMode LED Source (BC# 17577M)
    • MM Source:
      • 850nm
      • 1300nm
    • SC Connector For Source
  • ODM RP460 Fiber Optic Power Meter (BC# 17574M)
    • Power Meter:
      • 850nm
      • 1310nm
      • 1490nm
      • 1550nm
    • 2.5mm Adapter For Power Meter
    • LC Adapter
  • USConec IBC Brand Cleaner MPO II
  • ChemTronics AC092 SqR Pad w/ Pash Pen
  • ODM AC 533 LC Clipped To LC-SC MM fiber Cable
  • ODM AC 523 LC Clipped to LC-SC SM Fiber Cable
  • ODM AC4600 LC Loopback 2dB, DX, MM
  • (2) LC-LC Duplex Adapters
  • SC-SC Adapter
  • (10) 2.5mm Connector Cleaning Swabs