RAE Systems UltraRAE PGM-7200 PID VOC Monitor
$1,095.00
Availability:
Out of stock
SKU
RS08
Condition: Refurbished
Warranty: 90 Day Exchange
Request a Quote for
RAE Systems PGM-7200 VOC Monitor
The UltraRAE is a hand-held, programmable Compound Specific PID monitor designed to provide instantaneous exposure monitoring of a specific organic gas for workers in hazardous environements. It monitors a specific gas by utilizing a gas sepratation tube and the Photo-Ionization Detector (PID) with a 9.8 eV, 10.6 eV, or 11.7 eV gas discharge lamp. It also can be used to measure total Volatile Organic Compound (VOC) by uitlizing a straight through tube and the PID as a broad band monitor.
Features:
Specifications:
For full RAE Systems UltraRAE PGM-7200 product specifications, please click here: RAE Systems UltraRAE PGM-7200
The UltraRAE is a hand-held, programmable Compound Specific PID monitor designed to provide instantaneous exposure monitoring of a specific organic gas for workers in hazardous environements. It monitors a specific gas by utilizing a gas sepratation tube and the Photo-Ionization Detector (PID) with a 9.8 eV, 10.6 eV, or 11.7 eV gas discharge lamp. It also can be used to measure total Volatile Organic Compound (VOC) by uitlizing a straight through tube and the PID as a broad band monitor.
Features:
- Lightweight and Compact
- 20 oz (567 g), Cellular phone size
- Dpenedable and accurate
- 10 hours monitoring with micro controller
- User friendly
- Menu driven, intuitive end-use operation
- Programmable alarm thresholds
- Audio buzzer & flashing display alarm
Specifications:
Size: | 9.25"L x 3.0"W x 2.0"H |
Weight: | 21 oz (567 g) with battery pack |
Detector: | photo-ionization sensor with 9.8 eV UV lamp, optional 10.6 or 11.7 eV uV Lamps |
Battery: | rechargeable NiMH, NiCd, or Alkaline battery Pack (snap in, field replaceable) |
Battery charging: | 10 hours charge through bult-in charger or an external battery Charger |
Operating hours: | 10 hours continuous |
Display: | 1 line by 8 characters, 5x7 dot matrix LCD (0.4" character height) |
LED backlight: | automatic activation in dim light or alarm condition |
Total VOC Range, Resolution & Response Time: | Calibrated to 100 ppm isobutylene: 0-99 ppm 0.1 ppm 5 Sec 100-2000 ppm 1.0 ppm 5 Sec |
Specific Range, Resolution & measurement time: | Measurement Gas: Benzene: 0.1-200 ppm 0.1 ppm 60 sec 1,3-Butadiene: 0.1-200 ppm 0.1 ppm 75 sec Methylene Chloride 0.2-200 ppm 0.2 ppm 30 sec |
PID Detector: | Easy access to lamp and sensor for cleaning and replacement |
Filter: | Porous metal, for dust and particle filtering, field replaceable |
Inlet probe: | Teflon tube with ferrule fitting |
Keypad: | 1 operation key and 2 program keys |
Analog output: | 0 to 2.5 volt linear output |
Intrinsic Safety: | UL & cUL Class 1, Division 1, Gropus A, B, C, D (US & Canada) DEMKO 03 ATEX 0204759X Eex ia IIC Tg (Europe) |
EM interference: | no effect when exposed to 0.43 mW/cm RFI (5 watt transmitter at 12 inches) |
Alarm setting: | Preset alarm limites for two action levels |
Audible alarm: | Flashing red LED |
External Alarm | Optional plug in pen size vibration alarm or remote alarm |
Real-time Clock: | Automatic date and time stamps data logged information |
Data logging: | 4000 data points, incldues serial number user ID and site ID, date and time |
Communication | Down load data to PC and upload instrument setup from PC through RS-232 Link to serial port on PC |
Calibration: | Two-point field calibratino of zero and standard reference gas for compound specific vapor |
Sampling Pump: | internal integrated flow rate, 400 cc per minute minimum (VOC tube), low flow alarm |
Temperature | -20° to 45°C (-4° to 113°F) |
Humidity | 0% to 95% relative humidity (Non-condensing) |
Housing: | ABS + PC, conductive coating, splash and dust proof, will withstand 10' drop test |
Attachment: | Wrist strap |
For full RAE Systems UltraRAE PGM-7200 product specifications, please click here: RAE Systems UltraRAE PGM-7200
RAE Systems UltraRAE PGM-7200 PID Monitor
012-7021-E00
012-7021-E00 Options:
7: Monitor Only
0: 9.8 eV Lamp (Required For Benzene, Butadiene)
2: Rechargeable NiMH Battery, No Wall Adapter
1: Calibration Kit With Regulator (No Gas)
Designed to provide instantaneous exposure monitoring of a specific organic gas for workers in hazardous environments.
Includes Carrying Case & Accessories As Listed
PGM7200
RAE Systems PGM-7200 PGM 7200 PID VOC Monitor Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
012-7021-E00
012-7021-E00 Options:
7: Monitor Only
0: 9.8 eV Lamp (Required For Benzene, Butadiene)
2: Rechargeable NiMH Battery, No Wall Adapter
1: Calibration Kit With Regulator (No Gas)
Designed to provide instantaneous exposure monitoring of a specific organic gas for workers in hazardous environments.
Includes Carrying Case & Accessories As Listed
PGM7200
RAE Systems PGM-7200 PGM 7200 PID VOC Monitor Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 26261
- RAE Systems UltraRAE PGM-7200 PID VOC Monitor 012-7022-E00 (BC# 26261)
- 7: Monitor Only
- 0: 9.8 eV Lamp (Required For Benzene, Butadiene)
- 2: Rechargeable NiMH Battery, No Wall Adapter
- 1: Calibration Kit With Regulator (No Gas)
- RAE Gas Regulator
- RAE Systems Sensor RAE P/N: 032-3100-000
- RAE P/N: 081-0002-000 Lamp Cleaning Kit
- RAE P/N: 008-3003-000 Cable
- RAE P/N: 008-2009-010 10 Pack Dummy Sensors
- RAE P/N: 002-3008-000 Organic Vapor Zeroing Kit
- RAE P/N: 012-2502-005 Gas Detection Tubes
- RAE P/N: 025-2000-010 Gas Detecting Tubes
- (2) External Filters
- 7mm Adapter
- (2) Battery Packs
- AC Adapter/Charger
- User Manual On CD-ROM
- Strap For Unit
- Carrying Case