AFL FlowScout SE100 Single-Ended Test Set
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- AFL FlowScout SE100 Single-Ended Test Set (BC#: -L/T*)
- USB PC Interface Cable
- Carrying Case
AFL FlowScout SE100 Single-Ended Test Set
AFL’s FlowScout SE100 is designed to verify fiber continuity and measure
insertion loss to the end of fibers terminated with AFL’s 1430 nm
Wavelength Optical Reflectors. When a reflector is detected, the FlowScout SE100
immediately reports its presence (confirming continuity to the
reflector) and measures insertion loss to the reflector at 1430 nm wavelength.
The reflector is near-transparent to PON and other wavelengths,
allowing it to remain installed during network operation.
Reduce cost: Combining an optical light source and power
meter into one low-cost test set, the FlowScout SE100 enables a single
technician
to verify continuity and measure insertion loss, reducing equipment costs by
over 38% and labor costs by over 50%.
Shorten test time and eliminate setup errors: Traditional
two-ended testing requires equipment configuration and test coordination.
FlowScout SE100 eliminates time-consuming setup and technician coordination
time. It also speeds up testing by reducing visits to subscriber
premises, demarcation points, and cell tower climbs.
Enhance customer experience: The FlowScout SE100 eliminates
the need for onsite troubleshooting of FTTH drop issues. All testing can be
completed from a distribution panel or splitter, eliminating technician time at
the subscriber premises and overcoming scheduling and access
challenges for both subscribers and service providers.
Increase technician safety: Repeated tower climbs for
troubleshooting FTTA fibers are eliminated by using the FlowScout SE100 to test
from
the ground to optical reflectors installed at the Radio Unit.
Ensure integrity of test results: FlowScout SE100 alerts the
user when excess reflection or a live signal is present on the tested network.
Reflection issues from damaged, open, mismatched, or dirty connectors often
result in poor network performance. FlowScout SE100 immediately
alerts the user and displays ORL when excess reflection is present.
Complements subscriber-installed ONT initiatives: Reducing
the need for FTTH premises visits, the FlowScout SE100 solution supports
service provider goals to reduce costs by adopting a subscriber self-install ONT
methodology.
Features:
- Verifies fiber continuity and insertion loss at 1430 nm from
a single end - Excess reflection (low ORL) detection at 1550 nm
- Live fiber detection and reporting
- Built-in optical continuous wave (CW) reflectometer
- Combines light source and power meter into a single unit
Specifications:
| OPTICAL | |
| Emitter Type | Laser |
| Safety Class | Class 1 |
| Fiber Type | Single-mode; compatible with all G.652, G.655, and G.657 SMF |
| Calibrated Wavelengths | 1430 and 1550 nm |
| Center Wavelength | 1430 ±5 nm; 1550 ±20 nm |
| Spectral Width | ≤5 nm |
| Output Power Level | -1 to -4 dBm CW |
| Output Power Stability | ±0.1 dB over 1 hour (after 1 minute warmup) |
| Detector Type | InGaAs PIN |
| Detection Range | Reflector detected / not detected up to 20 km (18 mi) with optical loss ≤9 dB at 1430 & 1550 nm and 1550 nm ORL ≥25 dB |
| Insertion Loss Measurement Range | At least 10 dB when ORL ≥25 dB @1550 nm | At least 6 dB when ORL in range 14 – 20 dB @ 1550 nm |
| Loss Accuracy | ±1.0 dB for loss in range 0 to 6 dB |
| Loss Resolution | 0.1 dB |
| Measurement Units | Loss in dB; ORL in dB |
| GENERAL | |
| Size | 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in) |
| Weight | ≤0.3 kg (≤0.7 lb) |
| Operating Temperature | -10 °C to +50 °C, 0 to 95% RH (non-condensing) |
| Storage Temperature | -30 °C to +60 °C, 0 to 95% RH (non-condensing, batteries installed) |
| Battery Power | 2 x AA alkaline batteries; user-replaceable |
| AC Power | Optional external AC power supply (100-240 VAC, 50-60 Hz; 5VDC @2A) |
| Battery life | Typical 120 hrs, minimum 75 hrs (continuous operation, backlight off) |
| Display | Backlit monochrome LCD |
| Shock and vibration | Drop test, 1 m, 6 planes |
| Optical Port | Fiber-coupled, 2.5 mm ceramic ferrule plus SC/APC connector adapter |