AFL FlowScout MPO OLTS Test Set

AFL FlowScout MPO OLTS Test Set

AFL FlowScout TPPM-XG Through-Mode PON Optical Power Meter

AFL FlowScout TPPM-XG Through-Mode PON Optical Power Meter

AFL FlowScout SE100 Single-Ended Test Set

$1,195.00
Availability: In stock
SKU
4P284

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Shipping: USA & Worldwide

  • AFL FlowScout SE100 Single-Ended Test Set (BC#: -L/T*)
  • USB PC Interface Cable
  • Carrying Case
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

AFL FlowScout SE100 Single-Ended Test Set

AFL’s FlowScout SE100 is designed to verify fiber continuity and measure insertion loss to the end of fibers terminated with AFL’s 1430 nm
Wavelength Optical Reflectors. When a reflector is detected, the FlowScout SE100 immediately reports its presence (confirming continuity to the
reflector) and measures insertion loss to the reflector at 1430 nm wavelength. The reflector is near-transparent to PON and other wavelengths,
allowing it to remain installed during network operation.

Reduce cost: Combining an optical light source and power meter into one low-cost test set, the FlowScout SE100 enables a single technician
to verify continuity and measure insertion loss, reducing equipment costs by over 38% and labor costs by over 50%.

Shorten test time and eliminate setup errors: Traditional two-ended testing requires equipment configuration and test coordination.
FlowScout SE100 eliminates time-consuming setup and technician coordination time. It also speeds up testing by reducing visits to subscriber
premises, demarcation points, and cell tower climbs.

Enhance customer experience: The FlowScout SE100 eliminates the need for onsite troubleshooting of FTTH drop issues. All testing can be
completed from a distribution panel or splitter, eliminating technician time at the subscriber premises and overcoming scheduling and access
challenges for both subscribers and service providers.

Increase technician safety: Repeated tower climbs for troubleshooting FTTA fibers are eliminated by using the FlowScout SE100 to test from
the ground to optical reflectors installed at the Radio Unit.

Ensure integrity of test results: FlowScout SE100 alerts the user when excess reflection or a live signal is present on the tested network.
Reflection issues from damaged, open, mismatched, or dirty connectors often result in poor network performance. FlowScout SE100 immediately
alerts the user and displays ORL when excess reflection is present.

Complements subscriber-installed ONT initiatives: Reducing the need for FTTH premises visits, the FlowScout SE100 solution supports
service provider goals to reduce costs by adopting a subscriber self-install ONT methodology.

 

Features:

  • Verifies fiber continuity and insertion loss at 1430 nm from
    a single end
  • Excess reflection (low ORL) detection at 1550 nm
  • Live fiber detection and reporting
  • Built-in optical continuous wave (CW) reflectometer
  • Combines light source and power meter into a single unit

 

Specifications:

OPTICAL
Emitter Type Laser
Safety Class Class 1
Fiber Type Single-mode; compatible with all G.652, G.655, and G.657 SMF
Calibrated Wavelengths 1430 and 1550 nm
Center Wavelength 1430 ±5 nm; 1550 ±20 nm
Spectral Width ≤5 nm
Output Power Level -1 to -4 dBm CW
Output Power Stability ±0.1 dB over 1 hour (after 1 minute warmup)
Detector Type InGaAs PIN
Detection Range Reflector detected / not detected up to 20 km (18 mi) with optical loss ≤9 dB at 1430 & 1550 nm and 1550 nm ORL ≥25 dB
Insertion Loss Measurement Range At least 10 dB when ORL ≥25 dB @1550 nm | At least 6 dB when ORL in range 14 – 20 dB @ 1550 nm
Loss Accuracy ±1.0 dB for loss in range 0 to 6 dB
Loss Resolution 0.1 dB
Measurement Units Loss in dB; ORL in dB
GENERAL
Size 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)
Weight ≤0.3 kg (≤0.7 lb)
Operating Temperature -10 °C to +50 °C, 0 to 95% RH (non-condensing)
Storage Temperature -30 °C to +60 °C, 0 to 95% RH (non-condensing, batteries installed)
Battery Power 2 x AA alkaline batteries; user-replaceable
AC Power Optional external AC power supply (100-240 VAC, 50-60 Hz; 5VDC @2A)
Battery life Typical 120 hrs, minimum 75 hrs (continuous operation, backlight off)
Display Backlit monochrome LCD
Shock and vibration Drop test, 1 m, 6 planes
Optical Port Fiber-coupled, 2.5 mm ceramic ferrule plus SC/APC connector adapter