Agilent DualRemote 350 Cable Tester
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- DualRemote 350 version 3.2.8
- Agilent Scope Data Pro Software
- Battery Pack
- AC Adapter/Charger
- DC Car Charger
- USB PC Interface Cable
- Scope Data Pro Manual On CD-ROM
- User Manual On CD-ROM
The DualRemote 350 is controlled by the WireScope. The DualRemote displays information using LED indicators.
Control Buttons | The DualRemote 350 has the same control buttons on its face as the WireScope 350. |
Power: The Power button turns the unit on and off. | |
OK: Pressing the OK button does nothing. | |
Scroll: The Scroll button scrolls through the diagnostic indications. | |
Indicators | |
Pair Status Indicators |
|
The pair status indicators turn green or red at the end of a test to show the status of each pair. A red indicator means the associated pair failed the current test. | |
Warning Indicators |
|
The warning indicators denote conditions that might prevent or impair testing. | |
Hub/NIC Detected: The Hub/NIC Detected indicator means the DualRemote 350 is connected to a hub/Switch port or NIC port, instead of to a port connected to the WireScope 350. [This function is not yet supported.] | |
Voltage Warning: The voltage warning indicator means the DualRemote 350 is connected to a line which has a potentially damaging voltage present. This condition usually occurs when attempting to test a line that is connected to a telephone switch. | |
Calibration Required: The Calibration Required indicator means the DualRemote 350 is not calibrated to the WireSc pe 350. The autotest will not execute until the calibration is performed. | |
Battery: The battery indicator shows the current state of the DualRemote 350 battery charge. | |
When an external charger is supplying power to the DualRemote: ユ The Battery indicator is steady green when the battery is charging. |
|
When no external charger is connected to the DualRemote: ユ The Battery indicator is dark when the battery is operating normally. |
|
Test Progress and Result Indicators |
|
Progress: The Progress LEDs show approximately how much of the current test is complete, 1/3, 2/3, and complete. | |
Pass/Fail: The Pass/Fail indicator turns green when the test passes, or red when the test fails. | |
Diagnostics |
|
The Diagnostics section of the DualRemote 350 front panel provides more detailed information about failing test results. | |
WS and DR: Indicate at which end of the tested cable the measurement failed. ユWS lights when a failure occurs at the WireScope end of the circuit |
|
A column of diagnostic indicators shows details about the cause(s) of a test failure. The failures indicated on the DualRemote 350 are: |
|
Wiremap: Turns red when a fault with the cable connections is detected. | |
Split Pairs: Turns red when a split pair is detected. | |
Length/Delay/Skew: Turns red when cable length, signal delay, or skew are outside the passing limits. | |
NEXT : Turns red when near-end pair-to-pair or power sum faults are detected. | |
Attenuation: Turns red when attenuation is outside passing limits. | |
ELFEXT : Turns red when far-end pair-to-pair or power sum faults are detected. | |
Return Loss: Turns red when the return signal loss exceeds passing limits. | |
Other: Turns red when any other failing test results occur. If the cable run has multiple test failure causes, the Scroll button scrolls between diagnostic indications. The current selection blinks. The pair indicators and WS or DR indicators associated with the selected failure also blink. | |
Power |
|
The Power LED turns green when the DualRemote 350 is powered on. |
For full Agilent Wirescope 350 Dual Remote product specifications, please click here: Agilent Wirescope 350 Dual Remote