Agilent HP E4418B EPM Series Power Meter
$899.00
Availability:
In stock
SKU
KE03
Condition: Refurbished / Calibrated
Warranty: 1 Year Warranty
Agilent E4418B EPM Series Power Meter
The E4418B power meter is designed for bench and automatic test equipment (ATE) use.
Features:
Specifications:
For full Agilent E4418B specifications, please click here: Agilent E4418B
The E4418B power meter is designed for bench and automatic test equipment (ATE) use.
Features:
- Fast measurement speed (up to 200 readings per second, over the GPIB, with E-series sensors)
- Speed improvement of x2 using the 8480 series power sensor (compared to the 437B)
- No range-switching delays with 8480 series sensors, and only one fast-range switch point with E-series sensors
- Code compatibility with 437B and 436A power meters
- GPIB and RS232 connector for remote control of all functions
Specifications:
Compatible power sensors: | E4410 and E9300 E-Series, 8480 Series and N8480 Series average power sensors |
Frequency range: | 9 kHz to 110 GHz, sensor dependent |
Power range: | ヨ70 dBm to +44 dBm (100 pW to 25 W), sensor dependent |
Single sensor dynamic range: | 90 dB maximum (E-Series sensors) 50 dB maximum (8480 Series sensors) 55 dB maximum (N8480 Series sensors) |
Display units: | Absolute: Watts or dBm Relative: Percent or dB |
Display resolution: | Selectable resolution of 1.0, 0.1, 0.01, and 0.001dB in Log mode, or 1 to 4 digits in linear mode |
Default resolution: | 0.01 dB in log mode, 3 digits in linear mode |
Accuracy | |
Absolute: | ±0.02 dB (log) or ±0.5% (linear). |
Relative accuracy: | ±0.04 dB (log) or ±1.0% (linear). |
Zero set (digital settability of zero): | Sensor dependent. For E-Series sensors, this specification applies to a zero performed when the sensor input is not connected to the POWER REF. |
Zero drift of sensors: | Sensor dependent |
Measurement noise: | Sensor dependent |
Effects of averaging on noise: | Averaging over 1 to 1024 readings is available for reducing noise. Use the noise multiplier, for the appropriate mode (normal or x2) and number of averages, to determine the total measurement noise value. |
Measurement noise calculation: | (<45 pW x 2.75) = <121 pW |
Power reference | |
Power output: | 1.00 mW (0.0 dBm). Factory set to ±0.4% traceable to the National Physical Laboratory (NPL), UK1 . |
Accuracy: | For two years: ±0.5% (23 ± 3 °C) ±0.6% (25 ± 10 °C) ±0.9% (0 to 55 °C) |
Frequency: | 50 MHz nominal |
SWR: | 1.06 maximum |
Connector type: | Type-N (f), 50O |
Measurement speed Three measurement speed modes, over the GPIB, are available as shown, along with the typical maximum measurement speed for each mode. |
|
With E4418B power meter | Normal: 20 readings/second x2: 40 readings/second Fast: 200 readings/second |
Power meter functions | |
Accessed by key entry: | either hardkeys, or softkey menu, and programmable. |
Zero: | Zeros the meter. (Power reference calibrator is switched off during zeroing). |
Cal: | Calibrates the meter using internal (power reference calibrator) or external source. Reference cal factor settable from 1% to 150%, in 0.1% increments. |
Frequency: | Entered frequency range is used to interpolate the calibration factors table. |
Range: | 1 kHz to 999.9 GHz, settable in 1-kHz steps. |
Cal factor: | Sets the calibration factor for the meter. Range: 1% to 150%, in increments of 0.1%. |
Relative: | Displays all successive measurements relative to the last displayed value. |
Offset: | Allows power measurements to be offset by ヨ100 dB to +100 dB, settable in 0.001-dB increments, to compensate for external loss or gain. |
Save/recall: | Store up to 10 instrument states via the save/recall menu. |
dBm/W: | Selectable units of either Watts or dBm in absolute power; or percent or dB for relative measurements. |
Filter (averaging): | Selectable from 1 to 1024. Auto-averaging provides automatic noise compensation. |
Duty cycle: | Duty cycle values between 0.001% to 99.999%, in increments of 0.001%, can be entered to display a peak power representation of measured power. The following equation is used to calculate the displayed peak power value: peak power = measured power/duty cycle. |
Sensor cal tables: | Selects cal factor versus frequency tables corresponding to specified sensors (8480 Series only). |
Limits: | High and low limits can be set in the range ヨ150 dBm to +230 dBm, in 0.001-dBm increments. |
Preset default values: | dBm mode, rel off, power reference off, duty cycle off, offset off, frequency 50 MHz, AUTO average, free run, AUTO range (for ESeries and N8480 Series sensors). |
Display: | Selectable single and split screen formats are available. Aquasianalog display is available for peaking measurements. The dual-channel power meter can simultaneously display any two configurations of A, B, A/B, B/A, A-B, B-A and relative. |
General specifications | |
Dimensions | The following dimensions exclude front and rear protrusions: 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in) |
Weight | 4.0 kg (8.8 lb) net, 7.9 kg (17.4 lb) shipping |
Recorder outputs: | Analog 0 to 1-Volt, 1-k output impedance, BNC connector. E4419B recorder outputs are dedicated to channel A and channel B. |
Remote input/output: | A TTL logic level is output when the measurement exceeds a predetermined limit. TTL inputs are provided to initiate zero and calibration cycles. RJ-45 series shielded modular jack assembly connector. TTL Output: high = 4.8 V max; low = 0.2 V max TTL |
Input: | high = 3.5 V min, 5 V max; low = 1 V max, ヨ0.3 V min. |
GPIB: | Allows communication with an external controller |
RS-232/422: | Allows communication with an external RS-232/422 controller. Male/plug 9 position D-subminiature connector |
Ground: | Binding post, accepts 4-mm plug or bare-wire connection. |
Input voltage range: | 85 to 264 VAC, automatic selection. |
Input frequency range: | 50 to 440 Hz |
Power requirement: | Approximately 50 VA (14 W) |
Environmental characteristics | |
General conditions: | Complies with the requirements of the EMC Directive 89/336/EEC. This includes Generic Immunity Standard EN 50082-1: 1992 and Radiated Interference Standard EN 55011: 1991/CISPR11:1990, Group 1 - Class A. |
Temperature: | 0°C to 55 °C |
Maximum humidity: | 95% at 40 °C (non-condensing). |
Minimum humidity: | 15% at 40 °C (non-condensing). |
Maximum altitude: | 3000 meters (9840 feet). |
Storage temperature: | ヨ20 °C to +70 °C. |
Non-operating maximum humidity: | 90% at 65 °C (non-condensing) |
Non-operating maximum altitude: | 15240 meters (50,000 feet) |
Conforms to the following product safety specifications: | EN61010-1: 1993/IEC 1010-1: 1990 +A1/CSA C22.2 No. 1010-1: 1993 EN60825-1: 1994/IEC 825-1: 1993 Class 1 Low Voltage Directive 72/23/EEC |
Remote programming | |
Interface: | GBIB interface operates to IEEE 488.2. RS-232 and RS-422 serial interface supplied as standard |
Command language: | SCPI standard interface commands. 436A and 437B code compatible (E4418B only |
GPIB compatibility: | SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP1, DC1, DT1, C0. |
Battery: | Lithium polycarbon monoflouride, approximate lifetime 5 years at 25 °C |
For full Agilent E4418B specifications, please click here: Agilent E4418B
Agilent E4418B EPM Series Power Meter
Please Note That This Sale Is For The E4418B Power Meter Only, No Power Sensors Are Included!
The E4418B power meter is designed for bench and automatic test equipment (ATE) use
Includes Accessories As Listed
Agilent E4418B E-4418B Power Meter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 23569-L/T*
- Agilent E4418B EPM Series Power Meter (BC# 23569-L/T*)
- Ethernet Cable
- BNC Cable
- Power Cord
- RS232 PC Interface Cable
Request a Quote for