The E4418B power meter is designed for bench and automatic test equipment (ATE) use.
Features:
Specifications:
For full Agilent E4418B specifications, please click here: Agilent E4418B
The E4418B power meter is designed for bench and automatic test equipment (ATE) use.
Features:
- Fast measurement speed (up to 200 readings per second, over the GPIB, with E-series sensors)
- Speed improvement of x2 using the 8480 series power sensor (compared to the 437B)
- No range-switching delays with 8480 series sensors, and only one fast-range switch point with E-series sensors
- Code compatibility with 437B and 436A power meters
- GPIB and RS232 connector for remote control of all functions
Specifications:
Compatible power sensors: | E4410 and E9300 E-Series, 8480 Series and N8480 Series average power sensors |
Frequency range: | 9 kHz to 110 GHz, sensor dependent |
Power range: | ヨ70 dBm to +44 dBm (100 pW to 25 W), sensor dependent |
Single sensor dynamic range: | 90 dB maximum (E-Series sensors) 50 dB maximum (8480 Series sensors) 55 dB maximum (N8480 Series sensors) |
Display units: | Absolute: Watts or dBm Relative: Percent or dB |
Display resolution: | Selectable resolution of 1.0, 0.1, 0.01, and 0.001dB in Log mode, or 1 to 4 digits in linear mode |
Default resolution: | 0.01 dB in log mode, 3 digits in linear mode |
Accuracy | |
Absolute: | ±0.02 dB (log) or ±0.5% (linear). |
Relative accuracy: | ±0.04 dB (log) or ±1.0% (linear). |
Zero set (digital settability of zero): | Sensor dependent. For E-Series sensors, this specification applies to a zero performed when the sensor input is not connected to the POWER REF. |
Zero drift of sensors: | Sensor dependent |
Measurement noise: | Sensor dependent |
Effects of averaging on noise: | Averaging over 1 to 1024 readings is available for reducing noise. Use the noise multiplier, for the appropriate mode (normal or x2) and number of averages, to determine the total measurement noise value. |
Measurement noise calculation: | (<45 pW x 2.75) = <121 pW |
Power reference | |
Power output: | 1.00 mW (0.0 dBm). Factory set to ±0.4% traceable to the National Physical Laboratory (NPL), UK1 . |
Accuracy: | For two years: ±0.5% (23 ± 3 °C) ±0.6% (25 ± 10 °C) ±0.9% (0 to 55 °C) |
Frequency: | 50 MHz nominal |
SWR: | 1.06 maximum |
Connector type: | Type-N (f), 50O |
Measurement speed Three measurement speed modes, over the GPIB, are available as shown, along with the typical maximum measurement speed for each mode. |
|
With E4418B power meter | Normal: 20 readings/second x2: 40 readings/second Fast: 200 readings/second |
Power meter functions | |
Accessed by key entry: | either hardkeys, or softkey menu, and programmable. |
Zero: | Zeros the meter. (Power reference calibrator is switched off during zeroing). |
Cal: | Calibrates the meter using internal (power reference calibrator) or external source. Reference cal factor settable from 1% to 150%, in 0.1% increments. |
Frequency: | Entered frequency range is used to interpolate the calibration factors table. |
Range: | 1 kHz to 999.9 GHz, settable in 1-kHz steps. |
Cal factor: | Sets the calibration factor for the meter. Range: 1% to 150%, in increments of 0.1%. |
Relative: | Displays all successive measurements relative to the last displayed value. |
Offset: | Allows power measurements to be offset by ヨ100 dB to +100 dB, settable in 0.001-dB increments, to compensate for external loss or gain. |
Save/recall: | Store up to 10 instrument states via the save/recall menu. |
dBm/W: | Selectable units of either Watts or dBm in absolute power; or percent or dB for relative measurements. |
Filter (averaging): | Selectable from 1 to 1024. Auto-averaging provides automatic noise compensation. |
Duty cycle: | Duty cycle values between 0.001% to 99.999%, in increments of 0.001%, can be entered to display a peak power representation of measured power. The following equation is used to calculate the displayed peak power value: peak power = measured power/duty cycle. |
Sensor cal tables: | Selects cal factor versus frequency tables corresponding to specified sensors (8480 Series only). |
Limits: | High and low limits can be set in the range ヨ150 dBm to +230 dBm, in 0.001-dBm increments. |
Preset default values: | dBm mode, rel off, power reference off, duty cycle off, offset off, frequency 50 MHz, AUTO average, free run, AUTO range (for ESeries and N8480 Series sensors). |
Display: | Selectable single and split screen formats are available. Aquasianalog display is available for peaking measurements. The dual-channel power meter can simultaneously display any two configurations of A, B, A/B, B/A, A-B, B-A and relative. |
General specifications | |
Dimensions | The following dimensions exclude front and rear protrusions: 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in) |
Weight | 4.0 kg (8.8 lb) net, 7.9 kg (17.4 lb) shipping |
Recorder outputs: | Analog 0 to 1-Volt, 1-k output impedance, BNC connector. E4419B recorder outputs are dedicated to channel A and channel B. |
Remote input/output: | A TTL logic level is output when the measurement exceeds a predetermined limit. TTL inputs are provided to initiate zero and calibration cycles. RJ-45 series shielded modular jack assembly connector. TTL Output: high = 4.8 V max; low = 0.2 V max TTL |
Input: | high = 3.5 V min, 5 V max; low = 1 V max, ヨ0.3 V min. |
GPIB: | Allows communication with an external controller |
RS-232/422: | Allows communication with an external RS-232/422 controller. Male/plug 9 position D-subminiature connector |
Ground: | Binding post, accepts 4-mm plug or bare-wire connection. |
Input voltage range: | 85 to 264 VAC, automatic selection. |
Input frequency range: | 50 to 440 Hz |
Power requirement: | Approximately 50 VA (14 W) |
Environmental characteristics | |
General conditions: | Complies with the requirements of the EMC Directive 89/336/EEC. This includes Generic Immunity Standard EN 50082-1: 1992 and Radiated Interference Standard EN 55011: 1991/CISPR11:1990, Group 1 - Class A. |
Temperature: | 0°C to 55 °C |
Maximum humidity: | 95% at 40 °C (non-condensing). |
Minimum humidity: | 15% at 40 °C (non-condensing). |
Maximum altitude: | 3000 meters (9840 feet). |
Storage temperature: | ヨ20 °C to +70 °C. |
Non-operating maximum humidity: | 90% at 65 °C (non-condensing) |
Non-operating maximum altitude: | 15240 meters (50,000 feet) |
Conforms to the following product safety specifications: | EN61010-1: 1993/IEC 1010-1: 1990 +A1/CSA C22.2 No. 1010-1: 1993 EN60825-1: 1994/IEC 825-1: 1993 Class 1 Low Voltage Directive 72/23/EEC |
Remote programming | |
Interface: | GBIB interface operates to IEEE 488.2. RS-232 and RS-422 serial interface supplied as standard |
Command language: | SCPI standard interface commands. 436A and 437B code compatible (E4418B only |
GPIB compatibility: | SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP1, DC1, DT1, C0. |
Battery: | Lithium polycarbon monoflouride, approximate lifetime 5 years at 25 °C |
For full Agilent E4418B specifications, please click here: Agilent E4418B