Agilent Keysight E8362B PNA 20GHz Microwave Network Analyzer
$33,009.00
Availability:
In stock
SKU
9S112
Condition: Refurbished/Calibrated
Warranty: 1 Year Warranty
Shipping: USA & Worldwide
- Agilent E8362B PNA 20GHz Microwave Network Analyzer (BC# -L/T*)
- Power Cord
- User Manual on C
Request a Quote for
Agilent E8362B PNA 20GHz Microwave Network Analyzer
The Keysight Agilent HP E8362B PNA 20GHz Vector Network Analyzer provides the perfect combination of speed and precision for the demanding needs of high frequency, high-performance component test requirements.
The E8362B provides the right combination of fast sweep speeds, wide dynamic range, low trace noise and flexible connectivity. In addition, the E8362B now provides the capability to more accurately measure mixers and amplifiers with its new frequency-offset capability.
- Frequency Range of 10MHz to 20GHz
- 125dB of dynamic range at 20GHz
- <0.006dB of trace noise at 1kHz IFBW
- <26µsec/point measurement speed
- 32 measurement channels with up to 16,001 points per channel
- Supports TRM/LRM calibration for the most accurate on-wafer, in-fixture, and waveguide measurements
Description | Supplemental information |
System IF bandwidth range | 1 Hz to 40 kHz, nominal |
RF connectors | 3.5 mm (male), 50 Ω, (nominal), center pin recession flush to .002 in. (characteristic) |
Display | 8.4 in diagonal color active matrix LCD; 640 (horizontal) x 480 (vertical) resolution; 59.83 Hz vertical refresh rate; 31.41 Hz horizontal refresh rate |
Display range Magnitude Phase Polar |
±200 dB (at 20 dB/div), max ±500°, max 10 pico units, min; 1000 units, max |
Display resolution Magnitude Phase |
0.001 dB/div, min 0.01°/div, min |
Marker resolution Magnitude Phase Polar |
0.001 dB, min 0.01°, min 0.01 mUnit, min; 0.01°, min |
CPU | Intel® 1.1 GHz Pentium® M with 1 GByte RAM |
Line power (single phase) Frequency Max |
50/60/400 Hz for 100 to 120 V, 50/60 Hz for 220 to 240 V (Power supply is auto switching.) 350 Watts |
General environmental EMC Safety |
Complies with European EMC directive 89/336/EEC, amended by 93/68/EEC • IEC/EN 61326 • CISPR Pub 11 Group 1, class A • AS/NZS CISPR II:2002 • ICES/NMB-001 Complies with European Low Voltage Directive 73/23/EEC, amended by 93/68/EEC • IEC/EN 61010-1:2001 • Canada: CSA C22.2 No. 61010-1:2001 • USA: UL 61010-1 |
Operating environment Temperature Error-corrected temperature range Relative humidity Altitude |
0 to +40 °C; Instrument powers up, phase locks, and displays no error messages within this temperature range. (Except for ‘source unleveled’ error message that may occur at temperature outside the specified performance temperature range of 25 °C, ± 5 °C.) System specifications valid from 23 °C, ± 3 °C, with less than 1 °C deviation from the calibration temperature Type-tested, 0 to 95% at 40 °C, non condensing 0 to 4600 m (15,000 ft) |
Non-operating storage environment Temperature |
-40 to +70 °C |
Weight Net Shipping |
29 kg (64 lb), nom 36 kg (80 lb), nom. |