Agilent 3458A 8.5 Digit Digital Multimeter
Condition: Refurbished/Calibrated
Warranty: 1 Year Warranty
Shipping: USA & Worldwide
- Agilent 3458A 8.5 Digit Digital Multimeter (BC# - L/T)
- User Manual On CD-ROM
- Power Cable
Agilent 3458A 8.5 Digit Digital Multimeter
Reliably-Accurate Measurement Every Time
The Keysight Technologies, Inc. 3458A multimeter shatters longstanding performance barriers of speed and accuracy on the production test floor, in R&D, and in the calibration lab. The 3458A is simply the fastest, most flexible, and most accurate multimeter ever offered by Keysight. In your system or on the bench, the 3458A saves you time and money with unprecedented test system throughput and accuracy, seven function measurement flexibility, and low cost of ownership.
Select a reading rate of 100,000 readings/second for maximal test throughput. Or achieve highest levels of precision with up to 8.5 digits of measurement resolution and 0.1 part per million transfer accuracy. Add to this, programming compatibility through the Keysight multimeter language (ML) and the 3458A’s simplicity of operation and you have the ideal multimeter for your most demanding applications.
Access Speed and Accuracy Through a Powerful, Convenient Front Panel
- Simple to use, for bench measurements of DCV, ACV, ohms, current, frequency and period
- Select autorange or manual ranging
Menu command keys
- Immediate access to eight common commands
- Shifted keys allow simple access to complete command menu
Numeric/user keys
- Numeric entry for constants and measurement parameters
- Shifted keys (F0 through F9) access up to ten user-defined setups
Volts/ohms/ratio terminals
- Gold-plated tellurium copper for minimum thermal emf
- 2-wire or 4-wire ohms measurements
- DC/DC or AC/AC ratio inputs
Current measurement terminals
- Easy fuse replacement with fuse holder built into terminal
Guard terminal and switch
- For maximum common mode noise rejection
Front-rear terminal switch
- Position selects front or rear measurement terminals
Faster testing
- Up to 100,000 readings/second
- Internal test setups > 340/second
- Programmable integration times from 500 ns to 1 second
Greater test yield
- More accuracy for tighter test margins
- Up to 8.5 digits resolution
Longer up-time
- Two-source (10 V, 10 kΩ) calibration, including AC
- Self-adjusting, self-verifying auto-calibration for all functions and ranges
Superb transfer measurements
- 8.5 digits resolution
- 0.1 ppm DC volts linearity
- 0.1 ppm DC volts transfer capability
- 0.01 ppm rms internal noise
Extraordinary accuracy
- 0.6 ppm for 24-hours in DC volts
- 2.2 ppm for 24-hours in ohms
- 100 ppm mid-band AC volts
- 8 ppm (4 ppm optional) per year voltage reference stability
Greater waveform resolution and accuracy
- 16 to 24 bits resolution
- 100,000 to 0.2 samples/sec
- 12 MHz bandwidth
- Timing resolution to 10 ns
- Less than 100 ps time jitter