Ando AQ-6315E Optical Spectrum Analyzer 350 - 1750nm

$23,499.00
Availability: In stock
SKU
3F202

Condition: Refurbished / Calibrated

Warranty: 1 Year Warranty

Ando AQ-6315E Optical Spectrum Analyzer

The AQ6315E optical spectrum analyzer (OSA) is an improved version of the well known Ando AQ6315A. This OSA can do spectrally resolved intensity measurements in the range of 350 to 1750 nm with a wavelength accuracy better than 0.05 nm and supports single-pass/double-pass monochromator mode select. In the single-pass monochromator mode, it supports the same wide range of applications as previous models. In the double-pass monochromator mode, the dynamic range is improved to -90dBm. The system is sensitive enough to measure light intensities as low as a few picowatts, and in a single measurement can cover a dynamic range of seven orders of magnitude, allowing for the simultaneous viewing of low intensity and high intensity signals such as spontaneous emission and laser emission from a laser cavity. It has several integrated measurement modes, from simple optical absorption measurements to full optical amplifier parameter analysis. This unit supports diverse analysis functions for DWDM and other optical devices (LD, LED, FBG, etc).

Major Features

Diverse analysis functions Analysis functions for WDM and other optical devices (LD, LED, FBG, etc.). High wavelength accuracy Provides ±0.05 nm wavelength accuracy in the 1550 nm band, with ±0.02 nm wavelength linearity, makes it especially useful for WDM devices, such as high-precision loss wavelength characteristic evaluation. Monochromator select mode The monochromator mode can be set to single-pass or double-pass to match your measurement application needs.High sensitivity over a wide band Covers from 350nm to 1750nm and noise level has been suppressed to allow the AQ-6315A/-6315B to measure light at down to 90BmLow polarization dependency Polarization dependency has been slashed to ±0.05dB, enabling accurate measurement of optical amplifier gain and other critical measurements.High-level accuracy Accurate to within ±0.3dB.High-power measurement: Max.+20dBm (100mW) Even high power output from an optical amplifier can be measured directly without an optical attenuator High wavelength resolution Achieves wavelength resolution of 0.05nm.Optical output is provided (AQ6315B only) Can be used as an optical band pass filter.Three individual trace memories Pulsed light can be measured 9.4-inch color LCD

Specifications

Single-pass monochromator mode Double-pass monochromator mode

Applicable fiber

SM to 800μm diameter fiber SM, GI (50/62.5μm)

Measurement wavelength range

350 to 1750nm

Wavelength span

0 to 1500nm

Wavelength accuracy

0.5nm (25 ± 5°C, 10/125 SM fiber)

±0.05nm (1510 to 1570nm, 10/125 SM fiber)

Wavelength linearity

±0.02nm (1510 to 1570nm, 10/125 SM fiber)[1]

Wavelength reproducibility

±0.005nm (1 minute)

Wavelength resolution

0.05 to 10nm

Measurement level range [2]

-90 to +20dBm (1000 to 1600nm)
-85 to +20dBm (600 to 1000nm)
-75 to +20dBm (350 to 1750nm)
-85 to +20dBm (1200 to 1600nm)
-80 to 20dBm (600 to 1200nm)
-65 to +20dBm (350 to 1750nm)

Level accuracy [3]

±0.3dB (at 633/1310/1550nm)

Polarization dependency [4]

±0.1dB (at 1310/1550nm) ±0.05dB (at 1310/1550nm)

Linearity [5]

±0.05dB (0 to -40dBm), ±0.2dN (0 to –60dBm)

Level scale

0.1 to 10dB/div. And linear

Dynamic range (stray light level) [6]

40dB (± 1nm, 633/1152/1523nm
35dB (± 0.5nm, 633/1152/1523nm)
70dB (± 1nm, 633/1152/1523nm)
60dB (± 0.5nm, 633/1152/1523nm)

Sweep time [7]

0.5 s. or less (span 500nm or less), 2.5 s. or less (full span)

Functions

Measurement

Automatic measurement, marker-to-marker sweep measurement, averaging, pulsed light measurement function. Power meter function

Display

3D display, split (dual) display

Individual 3 trace memories

Max./min. hold, data calculation (addition, subtraction, division), normalize,Dominant, curve-fit display, power density display function, dBm/km, % level scale

Data analysis

Peak/bottom searches, spectral width search, SMSR search. Marker to marker power measurement function, optical amplifier NF measurement function, color analysis function, WDM analysis function, notch width measurement function

Other

Program function (200 steps×20 programs), wavelength calibration function, calendar/date function, help function, user key define function, label function

Optical output [8]

Resolution setting range: 0.05 to 10nm
Insertion loss: 20dB or less (1310/1550nm)
Optical fiber: GI 50/125μm
 

Memory

FDD-Traces, analysis data and programs on 3.5-inch FD (1.2/1.44 Mbyte)

Internal memory-Traces and measurement conditions (32 traces), 20 programs

Data Output

Printer-High-speed built-in printer

Plotter-Direct output to XY plotter

Interfaces

GP-IB-2 ports

Other Sweep trigger input (TTL), sample trigger input (TTL), sample trigger output (TTL)Sample enable input (TTL), 270Hz output (TTL), analog output (0-5V),Video output (VGA compatible

Display

9.4-inch color LCD, resolution 640×480 dots

Optical input connector

FC (standard) SC, D4, W/E, ST, DIN, etc

Power requirements

AC100V to 120V, 200V to 240V, 48 to 83Hz, approx. 200VA

Environment

Operating temperatures: 5°C to 40°C
Storage temperatures: -10°C to 50°C
Humidity: 80% or less (no condensation)
 

Dimensions and mass

Approx. 425 (W) ×222 (H) × 450 (W) mm, approx. 30kg

Notes

Note that device adapters, quartz cells for liquid measurement, parallel beam mounts, and white light sources are optional. Please consult with your vendor separately.
*These specifications are for products delivered later than October 1997
NOTE:
[1] After power-on and more than two hours of warm-up, within 24 hours from wavelength calibration with 1523nm HE-NE laser.
[2] At 25 ± 5°C. Resolution 0.5nm or more.
[3] 10/125 SM fiber, 25 ± 5°C, input level -30dBm or more
[4] 10/125 SM fiber, 25 ± 5°C, resolution 0.5nm or more
[5] 25 ± 5°C, sensitivity HIGH 3.
[6] 10/125 SM fiber, 25 ± 5°C, resolution 0.05nm, excluding high-order and low0order harmonics
[7] Single-trace display, sampling points: 501, sensitivity NORMAL HOLD. Average time: 1, no changes of diffraction order within sweep range except the full span
[8] AQ6315B only
Specifications are subject to change without notice
 

Ando AQ-6315E Optical Spectrum Analyzer

The AQ6315E optical spectrum analyzer (OSA) is an improved version of the well known Ando AQ6315A. This OSA can do spectrally resolved intensity measurements in the range of 350 to 1750 nm with a wavelength accuracy better than 0.05 nm and supports single-pass/double-pass monochromator mode select.


Includes Accessories As Listed!

BC# -L/T*

Ando AQ-6315E AQ6315E Spectrum Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

  • Ando AQ-6315E Optical Spectrum Analyzer (BC# -L/T*) 
  • Power Cord
  • User Manual On CD Rom
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!