Anritsu MA24350A 50 GHz Microwave CW USB Power Sensor

Anritsu MA24350A 50 GHz Microwave CW USB Power Sensor

Anritsu MA24126A 26 GHz Microwave USB Power Sensor

Anritsu MA24126A 26 GHz Microwave USB Power Sensor

Anritsu MA24208A 8 GHz Microwave Universal USB Power Sensor

$5,595.00
Availability: In stock
SKU
6C226

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Shipping: USA & Worldwide

  • Anritsu MA24208A 8 GHz Microwave Universal USB Power Sensor (BC# -L/T*)
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

Anritsu MA24208A 8 GHz Microwave Universal USB Power Sensor

 The MA24208A power sensor is designed to provide fast, accurate average power measurements from 10 MHz to 8 GHz over 80 dB of dynamic range. The sensor employs a patented "triple path" architecture that provides True-RMS measurements (similar to thermal sensors) over the entire frequency and dynamic range, enabling users to make highly accurate average power measurements for CW, multi-tone, and digitally modulated signal up to 8 GHz.

The sensor employs high-performance digital processing that enables best-in-class measurements speeds, including >1,600 continuous power readings/s continuous and >11,000 buffered readings/s.

A unique, low noise design eliminates the need to zero the sensor before taking measurements for most applications.

The sensors have internal and external triggering capability that facilitates individual slot power measurements of TDMA waveforms as well as burst power measurements of periodic and non-periodic waveforms.

The best-in-class damage protection combined with the silicone protective covering give the sensor increased ruggedness and enable users to protect their investment.

 

Features:

  •  Frequency range: 10 MHz — 8 GHz
  • Power measurement range: +20 dBm — -60 dBm
  • True RMS measurements – modulation independent
  • Fast measurement speed: >1,6001 readings/s continuous, >11,000 readings/s buffered1
  • Able to accept high power levels before being damaged: +30 dBm CW, +34 dBm 10 µs
  • NIST traceable calibrations
  • Compatible with Anritsu handheld instruments
  • Silicone protective covering for additional field durability
  • Worldwide calibration and service centers

 

Specifications:

Frequency Range 10 MHz — 8 GHz
Dynamic Range -60 dBm — +20 dBm
SWR (x:1) <1.17, 50 MHz — 150 MHz
<1.12, 150 MHz — 2 GHz
<1.22, 2 GHz — 8 GHz
Measurement Uncertainty (dB) +20 dBm — +4 dBm:
10 MHz — 50 MHz - 0.14
50 MHz — 2 GHz - 0.15
2 GHz — 8 GHz - 0.15
+4 dBm — -16 dBm : 
10 MHz — 50 MHz - 0.14
50 MHz — 2 GHz - 0.14
2 GHz — 8 GHz - 0.13
-16 dBm — -60 dBm:
10 MHz — 50 MHz - 0.14
50 MHz — 2 GHz - 0.14
2 GHz — 8 GHz - 0.13
RF Connector N(m)