Rohde & Schwarz ZVH4 3.6 GHz Cable & Antenna Analyzer

Rohde & Schwarz ZVH4 3.6 GHz Cable & Antenna Analyzer

Anritsu MW82119A PIM Master Passive Intermodulation Analyzer w/ Opt 190

Anritsu MW82119A PIM Master Passive Intermodulation Analyzer w/ Opt 190

Anritsu Cell Master MT8212E Base Station Analyzer w/ Opts: 21/31/541/542

$6,449.00
Availability: In stock
SKU
9S74

Condition: Refurbished / Calibrated

Warranty: 1 Year Exchange

Shipping: USA & Worldwide

  • Anritsu Cell Master MT8212E Base Station Analyzer w/ Options: (BC# 38010-L/T*)
    • Option 21: 2-Port Transmission Measurement
    • Option 31: GPS Receiver (Requires P/N: 2000-1528-R GPS Antenna)
    • Option 541: LTE Channel Power Accuracy Tests
    • Option 542: LTE Frequency Error Tests 
  • Generic Open/Short/Load
  • Armored Test Port Cable
  • (2) BNC Cables
  • DC Car Charger
  • AC Adapter/Charger
  • Power Cord
  • USB PC Interface Cable
  • User Manual On Cd-ROM
  • Carrying Case w/ Strap
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

 Anritsu Cell Master MT8212E Base Station Analyzer
Anritsu introduces its latest generation compact handheld Base Station Analyzer for installation and maintenance of wireless networks. Designed as a lightweight base station tester meeting virtually all testing needs by an RF technician. The Cell Master features Signal Analyzer options for 2G, 3G and 4G cellular networks including LTE, and WiMAX for digital broadcast.

This optimal combination of base station test capabilities in one handheld device eliminates the need for several independent test instruments, thereby reducing the number of tools the user must carry and learn to operate. Whether it's sweeping cables, making power measurements, finding interference, troubleshooting base station signal quality, or verifying backhaul performance, the Cell Master MT8212E is the ideal all-in-one instrument to help keep your network up and running.

Spectrum & Interference Analyzer Highlights:

  • Measurements: Occupied Bandwidth, Channel Power, ACPR, C/I
  • Interference Analyzer: Spectrogram, Signal Strength, RSSI, Signal ID
  • Dynamic Range: > 95 dB in 1 Hz RBW
  • DANL: -152 dBm in 10 Hz RBW
  • Phase Noise: -100 dBc/Hz max @ 10 kHz offset at 1 GHz
  • Frequency Accuracy: < ±50 ppb with GPS On


Specifications:

Spectrum Analyzer
Smart Measurements Field Strength (uses antenna calibration tables to measure dBm/m2 or dBmV/m)
Occupied Bandwidth (measures 99% to 1% power channel of a signal)
Channel Power (measures the total power in a specified bandwidth)
ACPR (adjacent channel power ratio)
AM/FM/SSB Demodulation (wide/narrow FM, USB and LSB), (audio out only)
C/I (carrier-to-interference ratio)
Setup Parameters
Frequency Center/Start/Stop, Span, Frequency Step, Signal Standard, Channel #
Amplitude Reference Level (RL), Scale, Attenuation Auto/Level, RL Offset, Pre-Amp On/Off, Detection
Span Span, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span
Bandwidth RBW, Auto RBW, VBW, Auto VBW, RBW/WBW, Span/RBW
File Save, Recall, Delete, Directory Management
Save/Recall Setups, Measurements, Limit Lines, Screen Shots Jpeg (save only), Save-on-Event
Save-on-Event Crossing Limit Line, Sweep Complete, Save-then-Stop, Clear All
Delete Selected File, All Measurements, All Mode Files, All Content
Directory Management Sort Method (Name/Type/Date), Ascend/Descend, Internal/USB, Copy, Format USB
Application Options Bias-Tee (On/Off), Impedance (50 O, 75 O, Other)
Sweep Functions
Sweep Single/Continuous, Manual Trigger, Reset, Detection, Minimum Sweep Time, Trigger Type,
Gated Sweep (see Option 0090)
Detection Peak, RMS, Negative, Sample, Quasi-peak
Triggers Free Run, External, Video, Change Position, Manual
Trace Functions
Traces Up to three Traces (A, B, C), View/Blank, Write/Hold, Trace A/B/C Operations
Trace A Operations Normal, Max Hold, Min Hold, Average, # of Averages, (always the live trace)
Trace B Operations A ? B, B??C, Max Hold, Min Hold
Trace C Operations A ? C, B??C, Max Hold, Min Hold, A - B ? C, B - A ? C, Relative Reference (dB), Scale
Marker Functions
Markers Markers 1-6 each with a Delta Marker, or Marker 1 Reference with Six Delta Markers, Marker Table (On/Off), All Markers Off
Marker Types Style (Fixed/Tracking), Noise Marker, Frequency Counter Marker
Marker Auto-Position Peak Search, Next Peak (Right/Left), Peak Threshold %, Set Marker to Channel, Marker Frequency to Center, Delta Marker to Span, Marker to Reference Level
Marker Table 1-6 markers frequency and amplitude plus delta markers frequency amplitude and offset
Limit Line Functions
Limit Lines Upper/Lower, On/Off, Edit, Move, Envelope, Advanced, Limit Alarm, Default Limit
Limit Line Edit Frequency, Amplitude, Add Point, Add Vertical, Delete Point, Next Point Left/Right
Limit Line Move To Current Center Frequency, By dB or Hz, To Marker 1, Offset from Marker 1
Limit Line Envelope Create Envelope, Update Amplitude, Points (41 max), Offset, Shape Square/Slope
Limit Line Advanced Type (Absolute/Relative), Mirror, Save/Recall
Frequency
Frequency Range 100 kHz to 4 GHz (usable to 0 Hz)
Maximum Continuous Input +26 dBm
Tuning Resolution 1 Hz
Frequency Reference Aging: ±1.0 ppm/year
Accuracy: ±1.5 ppm (25 °C ±25 °C) + aging, < ±50 ppb with GPS On
Frequency Span 10 Hz to 4 GHz including zero span
Sweep Time Minimum 100 ms, 10 µs to 600 seconds in zero span
Sweep Time Accuracy ±2% in zero span
Bandwidth
Resolution Bandwidth (RBW) 10 Hz to 3 MHz in 1ヨ3 sequence ±10% (1 MHz max in zero-span) (ヨ3 dB bandwidth)
Video Bandwidth (VBW) 1 Hz to 3 MHz in 1ヨ3 sequence (ヨ3 dB bandwidth)
RBW with Quasi-Peak Detection 200 Hz, 9 KHz, 120 kHz (-6 dB bandwidth)
VBW with Quasi-Peak Detection Auto VBW is On, RBW/VBW = 1
Spectral Purity
SSB Phase Noise @ 1 GHz -100 dBc/Hz, -110 dBc/Hz typical @ 10 kHz offset
-105 dBc/Hz, -112 dBc/Hz typical @ 100 kHz offset
-115 dBc/Hz, -121 dBc/Hz typical @ 1 MHz offset
Amplitude Ranges
Dynamic Range >95 dB (2.4 GHz), 2/3 (TOI-DANL) in 10 Hz RBW
Measurement Range DANL to +26 dBm
Display Range 1 to 15 dB/div in 1 dB steps, ten divisions displayed
Reference Level Range -130 dBm to +30 dBm
Attenuator Resolution 0 to 55 dB in 5 dB steps
Amplitude Units Log Scale Modes: dBm, dBV, dBmv, dBµV
Linear Scale Modes: nV, µV, mV, V, kV, nW, µW, mW, W, kW
Amplitude Accuracy
100 kHz to 40 GHz

±1.25 dB, ±0.5 dB typical
Spurs
Residual Spurious <-90 dBm (RF input terminated, 0 dB input attenuation, > 10 MHz)
Input-Related Spurious <-75 dBc (0 dB attenuation, -30 dBm input, span <1.7 GHz, carrier offset >4.5 MHz)
Exceptions, typical <-70 dBc @ <2.5 GHz, with 2072.5 MHz Input
<-68 dBc @ F1-280 MHz with F1 Input
<-70 dBc @ F1 + 190 MHz with F1 Input
<-52 dBc @ 7349-2F2 MHz, with F2 Input, where F2 < 2424.5 MHz
Third-Order Intercept (TOI)
Preamp Off (-20 dBm tones 100 kHz apart, 10 dB attenuation)
800 MHz +16 dBm
2400 MHz +20 dBm
200-2200 MHz +25 dBm, typical
>2.2 GHz to 4.0 GHz +28 dBm, typical
Second Harmonic Distortion
Preamp Off, 0 dB input attenuation, -30 dBm input
50 MHz -56 dBc
>50 MHz to 200 MHz -60 dBc, typical
>200 MHz to 3000 MHz -70 dBc, typical
VSWR
2:1, typical




For full Anritsu MT8212E Base Station product specifications, please click here: Anritsu MT8212E