Anritsu introduces the first fully integrated Passive Intermodulation (PIM) Analyzer suitable for commissioning and maintaining global wireless networks. This high performance, battery operated unit allows operators to fully characterize infrastructure quality by measuring Return Loss, VSWR, Cable Loss, Passive Intermodulation, Distance-to-Fault, and Distance-to-PIM with a single test instrument.
Passive Intermodulation (PIM) Analyzer Highlights
- PIM vs. Time, Swept PIM, Noise Floor, Distance-to-PIM
- 3rd, 5th, and 7th order intermodulation products
- 2nd order intermodulation products with Option 902
- Test Power: 20 dBm to 46 dBm
- Residual PIM: –125 dBm typical
Capabilities and Functional Highlights
- Integrated solution
- Battery operated: >3.0 hour run time
- Display: 8.4 in (213 mm) daylight viewable
- IP54 rated for dust and water spray
- MIL-STD-810G drop test rated
- Stainless steel lifting rings
- Padded soft case for extra protection
- Easy-to-use, menu driven user interface
- Quick Name Matrix simplifies naming in the field
Specifications:
Measurements | |
Measurements | PIM vs. Time Noise Floor Distance-to-PIM Swept PIM |
Setup Parameters | |
Frequency | Carrier F1, Carrier F2, Intermodulation Order |
Amplitude | Ref Value, Scale, Auto Range (On/Off), Amplitude Tone (On/Off) |
Setup | Output Power, Test Duration (1 s to 1,200 s) |
Limit Lines | Limit (Upper/Lower), On/Off, Limit Move, Limit Alarm (On/Off, PASS/FAIL indicator) |
Markers | Markers 1–6 (On/Off), Delta Markers 1–6 (On/Off), Marker to Peak/Valley, All Markers Of |
GPS | On/Off, 3.3/5.0 V |
DTP | Cable Velocity, Distance |
Save/Recall | Setups (.stp), Measurements (.pim), Limit Lines (.lim), Screen Shots (.jpg) (save only) |
PIM Measurement Ranges | |
Test Method | Reverse (reflected) Passive Intermodulation (PIM) per IEC-62037-1 |
Intermodulation Order | 3rd, 5th, and 7th order, when in receive band (user selectable) |
RF Test Power | Two CW tones 20 dBm to 46 dBm, 0.1 dBm steps Accuracy: ±0.5 dB (excluding uncertainty) |
RF Test Frequency | Accuracy: ±1.0 ppm at 23 ºC Stability: ±1.0 ppm from –10 ºC to +55 ºC, typical Aging: ±1.0 ppm/yr aging, typical |
Residual PIM Performance | <–117 dBm, <–125 dBm typical (2x 43 dBm test tones) <–134 dBm, <–140 dBm typical (2x 20 dBm test tones) |
PIM Measurement Range | –70 dBm to –140 dBm (Revision 1 instruments) –50 dBm to –140 dBm (Revision 2 instruments) |
General Specifications | |
PIM Master Connectors | |
PIM Test Port | 7/16 DIN, female, 50 Ω |
Dual USB Type A | 2x Type A (connect USB Flash Drive and USB Power Sensor) |
USB Mini-B | 1x Mini-B (connect to PC for data transfer) |
GPS | SMA, female (with GPS option only) |
External Power | 2.1 mm x 5.5 mm barrel connector, 12 VDC to 15 VDC, < 5.0 A |
PIM Test Port Damage Level | +10 dBm (10 mW) continuous, (PIM Rx band) +35 dBm (3 W) continuous, (PIM Tx band)* |
IM2/1900 MHz in Test Port | Type N, Female, 50 Ω (Option 902 and Option 600) |
IM2/1900 MHz in Test Port Damage level | +10 dBm (10 mW) continuous, (IM2/1900 MHz Rx band) |
VNA Test Port | Type N, female, 50 Ω (Option 331) |
VNA Test Port Damage Level | 40 dBm continuous |
Display | |
Size | 213 mm (8.4 in) touch screen |
Resolution | 800 x 600 |
Pixel Defects | No more than five defective pixels (99.9989% good pixels) |
Battery | |
Type | Li-Ion |
Battery Operation | 3.0 hours, typical |
Charging Limits | While charging, battery must be 0 °C to +45 °C, Relative Humidity ≤ 80 % |
Power | |
AC/DC Adapter | Input: 100VAC to 240 VAC, 50/60 Hz Output: 12 VDC |
Regulatory Compliance | |
European Union | EMC 2014/30/EU, EN 61326:2013, CISPR 11/EN 55011, IEC/EN 61000-4-2/3/4/5/6/8/11 Low Voltage Directive 2014/35/EU Safety EN 61010-1:2010 RoHS Directive 2011/65/EU applies to instruments with CE marking placed on the market after July 22, 2017 |
Australia and New Zealand | RCM AS/NZS 4417:2012 |
South Korea | KCC-REM-A21-0004 |
Environmental | |
Operating Temperature Range | –10 ºC to 55 ºC |
Storage Temperature Range | –51 ºC to 71 ºC |
Maximum Relative Humidity | 95 % RH at 30 ºC, non-condensing |
Vibration, Sinusoidal | 5 Hz to 55 Hz |
Vibration, Random | 10 Hz to 500 Hz |
Half Sine Shock | 30 g |
Altitude | 4600 meters, operating and non-operating |
Explosive Atmosphere | MIL-PRF-28800F, Section 4.5.6.3 MIL-STD-810G, Method 511.5, Procedure 1 |
Ingress Protection (IP) | IP54, IP67 when enclosed in optional transit case |
ESD | |
PIM Test Port Connector Center Pin | Withstands up to ±15 kV |
VNA RF Out Connector Center Pin | Withstands up to ±15 kV |
Size and Weight | |
Size | 350 mm x 314 mm x 152 mm (13.8 in x 12.4 in x 6.0 in) |
Weight | 9.2 kg to 12.4 kg (20 lb to 27 lb), varies by frequency option |
For full Anritsu MW82119B PIM Master product specifications, please click here: Anritsu MW82119B