Anritsu Site Master S331E Cable Antenna Analyzer w/ OPT. 10, 21
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Anritsu Site Master S331E w/ Options: (BC# 38542-L/T*)
- Option 10: Bias Tee
- Option 21: 2-Port Transmission Measurements
- BNC Cable
- Stylus
- DC Car Charger
- AC Adapter/Charger
- Power Cord
- USB PC Interface Cable
- User Manual On CD-ROM
- Anritsu Software Tool Box V1.04
- Carrying Case w/ Strap
S331E Cable and Antenna Analyzer Highlights
- Cable and Antenna Analyzer: 2 MHz ? 4 GHz
- Return Loss, VSWR, Cable Loss, Distance-To-Fault, Smith Chart, 1-Port Phase
- USB connectivity, built-in touch screen keyboard
- Field-proven design: Four-hour battery life, rugged, compact, lightweight, daylight viewable display
- Intuitive menu-driven touch screen user interface
To keep up in today's rapidly evolving wireless communications market, you need tools that enable you to efficiently maintain legacy networks in addition to the new 3G and 4G networks now being installed. And with rate of market expansion, you're being required to service more base stations than ever before. This means completing sweeps quickly, performing calibrations instantly, and implementing fast trace naming while in the field.
The S331E Site Master does all this while delivering the ease of use, rich functionality, and best-in-class price/performance you've come to expect from Anritsu. Designed to handle the most punishing field conditions, the S331E Site Master Cable and Antenna Analyzer dramatically enhances your productivity and transforms the traditional fix-after-failure maintenance model to one that identifies and fixes problems before major failures occur.
Measurements | |||
Measurements | VSWR | ||
Return Loss | |||
Cable Loss | |||
Distance-to-Fault (DTF) Return Loss | |||
Distance-to-Fault (DTF) VSWR | |||
1-Port Phase | |||
Smith Chart | |||
|
|||
Setup Parameters | |||
Measurement Display | Single/Dual Measurement Display with independent markers | ||
Frequency | Start/Stop, Signal Standard, Start Cal | ||
DTF | Start/Stop, DTF Aid, Units (m/ft), Cable Loss, Propagation Velocity, Cable, Windowing | ||
Windowing | Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe | ||
Amplitude | Top, Bottom, Auto Scale, Full Scale | ||
Sweep | Run/Hold, Single/Continuous, RF Immunity (High/Low), Data Points, Averaging/Smoothing, Output Power (High/Low) | ||
Data Points | 137, 275, 551, 1102, 2204 | ||
Markers | Markers 1-6 (On/Off), Delta Makers 1-6 (On/Off), Marker to Peak/Valley, Marker Table | ||
Traces | Recall, Copy to Display Memory, No Trace Math, Trace ± Memory, Trace Overlay | ||
Limit Line | On/Off, Single Limit, Multi-segment (41), Limit Alarm, Clear | ||
Calibration | Start Cal, Cal Type (Standard/FlexCal?) | ||
Save/Recall | Setups, Measurements (.vna, .dat), Screen Shots Jpeg (save only) | ||
Application Options | Bias-Tee (On/Off), Impedance (50 O, 75 O, Other) | ||
|
|||
Frequency | |||
Frequency Range | 2 MHz to 4 GHz | ||
Frequency Accuracy | = ± 2.5 ppm @ 25 °C | ||
Frequency Resolution | 1 kHz, (RF immunity low) 100 kHz, (RF immunity high) |
||
|
|||
Output Power | |||
High | 0 dBm, typical | ||
Low | ?30 dBm, typical | ||
|
|||
Interference Immunity | |||
On-Channel | +17 dBm @ > 1.0 MHz from carrier frequency | ||
On-Frequency | 0 dBm within ± 10 kHz of the carrier frequency | ||
|
|||
Measurement Speed | |||
Return Loss | = 1.00 msec/data point, RF immunity low, typical | ||
Distance-to-Fault | = 1.25 msec/data point, RF immunity low, typical | ||
|
|||
Return Loss | |||
Measurement Range | 0 to 60 dB | ||
Resolution | 0.01 dB | ||
|
|||
VSWR | |||
Measurement Range | 1 to 65 | ||
Resolution | 0.01 | ||
|
|||
Cable Loss | |||
Measurement Range | 0 to 30 dB | ||
Resolution | 0.01 dB | ||
|
|||
Distance-to-Fault | |||
Vertical Range Return Loss | 0 to 60 dB | ||
Vertical Range VSWR | 1 to 65 | ||
Fault Resolution (meters) | (1.5 x 108 x vp)/?F (vp = velocity propagation constant, ?F is F2-F1 in Hz) | ||
Horizontal Range (meters) | 0 to (Data Points-1) x Fault Resolution, to a maximum of 1500 meters (4921 ft) | ||
|
|||
1-Port Phase | |||
Measurement Range | ?180° to +180° | ||
Resolution | 0.01° | ||
|
|||
Smith Chart | |||
Resolution | 0.01 | ||
|
|||
Measurement Accuracy | |||
Corrected Directivity | > 42 dB, OSL Calibration | ||
> 38 dB, InstaCal? Calibration |
For full Anritsu S331E product specifications, please click here: Anritsu S331E