Features & Applications:

The Fluke 196/003 ScopeMeter high-performance oscilloscope offers specifications usually found on top-end bench instruments. With up to 200 MHz bandwidth and 2.5 GS/s real-time sampling and a deep memory of 27,500 points per input, it's ideal for engineers who need the full capabilities of a high-performance oscilloscope in a handheld, battery-powered instrument.


 

Features:

  • Dual-input ヨ 100 MHz bandwidth
  • Up to 1 GS/s real time sampling per input
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope (190)
  • Large, high resolution color or monochrome screen
  • Connect and view automatic triggering and a full range of manual trigger modes
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points per input record length using ScopeRecord mode
  • TrendPlot paperless chart recorder for trend analysis up to 22 days
  • UP to 1000 V independently floating isolated inputs
  • 1000 V CAT II and 600 V CAT III safety certified
  • Five hours rechargeable Ni-MH battery pack


 

Specifications
Bandwidth
Fluke 196B, Fluke 196C: 100 MHz
Real-time sample rate
Fluke 196B, Fluke 196C: 1 GS/s
Inputs and digitizers
2 plus external / DMM input
Independently floating isolated inputs
Up to 1000 V between inputs, references and ground
Timebase range
5 ns - 2 min/div
10 ns - 2 min/div (192B)
Input sensitivity
190B Models: 5 mV-100 V/div
Trigger types
Connect-and-Viewル, Free Run, Single Shot, Edge, Delay, Video, Selectable pulse width and External
Glitch capture
50 ns (5 µs/div - 1 min/div)
Scope measurements
Cursor: 7
Automatic: 30
Maximum record length
ScopeRecord mode: 27,500 pts per input
Scope mode: 3,000 pts per input
Memory
Screens: 10
Setups: 10
Display
190B Models: 144 mm full monochrome LCD with fast update rate
Persistence
190B Models: n/a
Waveform Compare
190B Models: Waveform reference only

Environmental Specifications
Operating Temperature
0 to 50ºC
Storage Temperature
-20 to +60°C
Operating Altitude
3,000 m

Safety Specifications
Electrical Safety
1,000V CAT II/600V CAT III (EN61010-1)

Mechanical & General Specifications
Size
256 x 169 x 64 mm
Weight
2.0 kg
Warranty
90 Day Exchange
Battery Life
NiMH: 4 hrs
RS-232 Interface
Optically isolated via optional PM9080/OC4USB for interfacing to Printer or PC

Microtest Pentascanner

  • EIA/TIA TSB-67 Level II and ISO Compliant
  • Category 5 tester
  • Storage of 500 Autotests
  • Power :
    • Rechargeable, replaceable battery pack
    • Battery life : 8 hours daily operation (appox. 6 hours in continuous Autotest)
  • Measurement Ports : BNC and Modular 8 (RJ-45)
  • Memory : test storage of up to 500 complete Autotest results
  • Autotest Functions : TIA TSB-67, ISO Class C, D, 10-Base T, Token Ring, Fast Ethernet, ATM 155 etc.
  • Up to 20 user definable Autotest programs
  • Near-End Crosstalk (NEXT) :
    • Tests all six pair combinations-
    • Frequency range : 0.7 to 100 MHz
  • Attenuation :
    • Tests all four pairs using far end active signal injection-
  • Frequency range : 1.0 to 100 MHz

 

Super Injector

Super Injector is a single direction active injector and remote test coordinator that work with Scanners to verify twisted-pair cable transmission quality. By using the Injector, the Scanner can test Attenuation, NEXT, Loop Resistance, and provide a Wire Map for any twisted-pair cable.

Frequency Range 0.7 to 100 MHz
Noise Impulse Noise
Peak to Peak Noise
Weight 1 lb, 12 oz
Battery life 8 hours daily operation (appox. 6 hours in continuous Autotest)
Measurement Ports BNC and Modular 8 (RJ-45)
Attenuation Tests all four pairs using far end active signal injection




For full Fluke 196 specifications, please click here: Fluke 196

Datacom & 100MHz Electrical Test Kit

Fluke 196/003 ScopeMeter, 1GS/s Dual-Input 100MHz HandHeld Oscilloscopes
&
Fluke Microtest PentaScanner Cat5 Cable Tester / Certifier and Coax Cable Tester with Super Injector

Super Injector Works With The PentaScanner To Verify Twisted-pair Cable Transmission Quality.

Includes Carrying Cases & Accessories As Listed!

Scope Meter Penta Scanner

  • Fluke 196 ScopeMeter 100MHz Oscilloscopes
  • (2) 10:1 Voltage Probe Sets 250MHz
  • 1000v Hard Point Test Leads (1 Red - 1 Black)
  • Flukeview ScopeMeter Software SW90W
  • AC Adapter/Charger
  • User Manual On CD-ROM
  • Carrying Case

 

  • Fluke Microtest PentaScanner
  • Fluke Microtest Super Injector
  • Cable Management Software
  • (2) Ethernet Patch Cables
  • RS232 PC Interface Cable
  • User Manual on CD-ROM
  • Battery Pack
  • AC Adapter/Charger
  • Carrying Case