Fluke 80i-110s side

Fluke 80i-110s AC/DC Clamp-On Current Probe

Fluke 1587 Digital Insulation Multimeter

$769.00
Availability: In stock
SKU
10H21

Condition: Refurbsihed / Calibrated

Warranty: 1 Year Warranty

Fluke 1587 Insulation Multimeter 

 

Two powerful tools in one

The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance. Like other tools that you have come to expect from Fluke, the 1587 and 1577 are rugged, reliable, and easy to use.

Whether you work on motors, generators, cables, or switch-gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks.

 

Features:

  • Large display with backlight
  • Insulation test (1587: 0.01 MΩ to 2 GΩ)
  • Insulation test voltages (1587: 50 V, 100 V, 250 V, 500 V, 1000 V)
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • Auto-discharge of capacitive voltage for added user protection
  • AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (Ω), Continuity
  • Filter for motor drive measurements
  • Capacitance, diode test, temperature, Min/Max, frequency (Hz)
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category

 

Specifications:

Accuracy
Range Resolution 50 Hz to 60 Hz 60 Hz to 5000 Hz
600.0 mV 0.1 mV + (1 % + 3) + (2 % + 3)
6.000 V 0.001 V + (1 % + 3) + (2 % + 3)
60.00 V 0.01 V + (1 % + 3) + (2 % + 3)
600.0 V 0.1 V + (1 % + 3) + (2 % + 3)
1000 V 1 V + (2 % + 3) + (2 % + 3)
Lowpass Filter Voltage
Range Resolution 50 Hz to 60 Hz 60 Hz to 400 Hz
600.0 mV 0.1 mV + (1 % + 3) + (2 % + 3)
6.000 V 0.001 V + (1 % + 3) + (2 % + 3)
60.00 V 0.01 V + (1 % + 3) + (2 % + 3)
600.0 V 0.1 V + (1 % + 3) + (2 % + 3)
1000 V 1 V + (2 % + 3) + (2 % + 3)
DC voltage measurement
Range Resolution Accuracy
6.000 V dc 0.001 V 0.09 % + 2
60.00 V dc 0.01 V 0.09 % + 2
600.0 V dc 0.1 V 0.09 % + 2
1000 V dc 1 V 0.09 % + 2
DC millivolts measurement
Range Resolution Accuracy
600.0 mV dc 0.1 mV 0.1 % + 1
DC and ac current measurement
Range Resolution Accuracy Burden Voltage (Typical)
AC
45 to 1000 Hz
400 mA: 0.1 mA
60 mA: 0.01 mA
± (1.5 % + 2)
± (1.5 % + 2)
2 mV/mA
DC 400 mA: 0.1 mA
60 mA:  0.01 mA
± (0.2 % + 2)
± (0.2 % + 2)
2 mV/mA
Ohms measurement
Range Resolution Accuracy  
600.0 Ω 0.1 Ω 0.9 % + 2  
6.000 kΩ 0.001 kΩ  
60.00 kΩ 0.01 kΩ  
600.0 kΩ 0.1 kΩ  
6.000 MΩ 0.001 MΩ  
50.0 MΩ 0.01 MΩ 1.5 % + 3  
Overload protection: 1000 V rms or dc
Open circuit test voltage: < 8.0 V dc
Short circuit current:  < 1.1 mA
Diode test (1587 Only)
Diode test indication: Display voltage drop: 0.6 V at 1.0 mA nominal test current
Accuracy: + (2 % + 1)
Continuity test
Continuity indication: C Continuous audible tone for test resistance below 25 Ω and off above 100 Ω. Maximum reading; 1000 Ω
Open circuit voltage: < 8.0 V
Short circuit current: 1.0 mA typical
Overload protection: 1000 V rms
Response time: > 1 m sec
Frequency measurement
Range Resolution Accuracy
99.99 Hz 0.01 Hz ± (0.1 % + 1)
999.9 Hz 0.1 Hz ± (0.1 % + 1)
9.999 kHz 0.001 kHz ± (0.1 % + 1)
99.99 kHz 0.01 kHz ± (0.1 % + 1)
General Specifications
Maximum voltage applied to any terminal: 1000 V ac rms or dc  
Storage temperature: -40 °C to 60 °C (-40 °F to 140 °F)  
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)  
Temperature coefficient: 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F)  
Relative humidity, non-condensing:  < °C 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) 0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) 0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)  
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument  
Shock 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)  
Electromagnetic compatibility: In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F). (EN 61326-1:1997)  
Safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V  
Certifications CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard EN 61010 Part 1-1002  
Batteries Four AA batteries (NEDA 15A or IEC LR6)  
Battery life: Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off  
Size 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)  
Weight 550 g (1.2 lb)  
IP rating: IP40  
Altitude (operating) 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V  
Storage 12,000 m  
Over-range capability: 110 % of range except for capacitance which is 1 %  
Compliance to EN 61557: IEC61557-1, IEC61557-2  
For full Fluke 1587 Insulation Multimeter product specifications, please click here: 1587

Fluke 1587 Insulation Multimeter

combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.

Refurbished Fluke 1587 Insulation Multimeter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 44608-L/T*

  • Fluke 1587 Insulation Multimeter (BC# 44608-L/T*)
  • (2) Fluke Flexible Test Leads
  • User Manual On CD-ROM
  • Carrying Case
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!