Fluke 1587 Digital Insulation Multimeter
$699.00
Availability:
In stock
SKU
10H21
Condition: Refurbsihed / Calibrated
Warranty: 1 Year Warranty
Shipping: USA & Worldwide
- Fluke 1587 Insulation Multimeter (BC# 44608-L/T*)
- (2) Fluke Flexible Test Leads
- User Manual On CD-ROM
- Carrying Case
Request a Quote for
Fluke 1587 Insulation Multimeter
Two powerful tools in one
The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance. Like other tools that you have come to expect from Fluke, the 1587 and 1577 are rugged, reliable, and easy to use.
Whether you work on motors, generators, cables, or switch-gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks.
Features:
- Large display with backlight
- Insulation test (1587: 0.01 MΩ to 2 GΩ)
- Insulation test voltages (1587: 50 V, 100 V, 250 V, 500 V, 1000 V)
- Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
- Auto-discharge of capacitive voltage for added user protection
- AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (Ω), Continuity
- Filter for motor drive measurements
- Capacitance, diode test, temperature, Min/Max, frequency (Hz)
- Auto power off to save battery power
- CAT III 1000 V, CAT IV 600 V measurement category
Specifications:
Accuracy | |||
Range | Resolution | 50 Hz to 60 Hz | 60 Hz to 5000 Hz |
600.0 mV | 0.1 mV | + (1 % + 3) | + (2 % + 3) |
6.000 V | 0.001 V | + (1 % + 3) | + (2 % + 3) |
60.00 V | 0.01 V | + (1 % + 3) | + (2 % + 3) |
600.0 V | 0.1 V | + (1 % + 3) | + (2 % + 3) |
1000 V | 1 V | + (2 % + 3) | + (2 % + 3) |
Lowpass Filter Voltage | |||
Range | Resolution | 50 Hz to 60 Hz | 60 Hz to 400 Hz |
600.0 mV | 0.1 mV | + (1 % + 3) | + (2 % + 3) |
6.000 V | 0.001 V | + (1 % + 3) | + (2 % + 3) |
60.00 V | 0.01 V | + (1 % + 3) | + (2 % + 3) |
600.0 V | 0.1 V | + (1 % + 3) | + (2 % + 3) |
1000 V | 1 V | + (2 % + 3) | + (2 % + 3) |
DC voltage measurement | |||
Range | Resolution | Accuracy | |
6.000 V dc | 0.001 V | 0.09 % + 2 | |
60.00 V dc | 0.01 V | 0.09 % + 2 | |
600.0 V dc | 0.1 V | 0.09 % + 2 | |
1000 V dc | 1 V | 0.09 % + 2 | |
DC millivolts measurement | |||
Range | Resolution | Accuracy | |
600.0 mV dc | 0.1 mV | 0.1 % + 1 | |
DC and ac current measurement | |||
Range | Resolution | Accuracy | Burden Voltage (Typical) |
AC 45 to 1000 Hz |
400 mA: 0.1 mA 60 mA: 0.01 mA |
± (1.5 % + 2) ± (1.5 % + 2) |
2 mV/mA |
DC | 400 mA: 0.1 mA 60 mA: 0.01 mA |
± (0.2 % + 2) ± (0.2 % + 2) |
2 mV/mA |
Ohms measurement | |||
Range | Resolution | Accuracy | |
600.0 Ω | 0.1 Ω | 0.9 % + 2 | |
6.000 kΩ | 0.001 kΩ | ||
60.00 kΩ | 0.01 kΩ | ||
600.0 kΩ | 0.1 kΩ | ||
6.000 MΩ | 0.001 MΩ | ||
50.0 MΩ | 0.01 MΩ | 1.5 % + 3 | |
Overload protection: | 1000 V rms or dc | ||
Open circuit test voltage: | < 8.0 V dc | ||
Short circuit current: | < 1.1 mA | ||
Diode test (1587 Only) | |||
Diode test indication: | Display voltage drop: 0.6 V at 1.0 mA nominal test current | ||
Accuracy: | + (2 % + 1) | ||
Continuity test | |||
Continuity indication: C | Continuous audible tone for test resistance below 25 Ω and off above 100 Ω. Maximum reading; 1000 Ω | ||
Open circuit voltage: | < 8.0 V | ||
Short circuit current: | 1.0 mA typical | ||
Overload protection: | 1000 V rms | ||
Response time: | > 1 m sec | ||
Frequency measurement | |||
Range | Resolution | Accuracy | |
99.99 Hz | 0.01 Hz | ± (0.1 % + 1) | |
999.9 Hz | 0.1 Hz | ± (0.1 % + 1) | |
9.999 kHz | 0.001 kHz | ± (0.1 % + 1) | |
99.99 kHz | 0.01 kHz | ± (0.1 % + 1) | |
General Specifications | |||
Maximum voltage applied to any terminal: | 1000 V ac rms or dc | ||
Storage temperature: | -40 °C to 60 °C (-40 °F to 140 °F) | ||
Operating temperature | -20 °C to 55 °C (-4 °F to 131 °F) | ||
Temperature coefficient: | 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) | ||
Relative humidity, non-condensing: | < °C 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) 0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) 0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) | ||
Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | ||
Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) | ||
Electromagnetic compatibility: | In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F). (EN 61326-1:1997) | ||
Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V | ||
Certifications | CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard EN 61010 Part 1-1002 | ||
Batteries | Four AA batteries (NEDA 15A or IEC LR6) | ||
Battery life: | Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off | ||
Size | 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) | ||
Weight | 550 g (1.2 lb) | ||
IP rating: | IP40 | ||
Altitude (operating) | 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V | ||
Storage | 12,000 m | ||
Over-range capability: | 110 % of range except for capacitance which is 1 % | ||
Compliance to EN 61557: | IEC61557-1, IEC61557-2 |