Fluke 283 FC CAT III 1500V Digital Multimeter
Unmatched safety and convenience for solar professionals
The CAT III 1500 V/CAT IV 1000 V True-RMS Fluke 283 FC Digital Multimeter
and a283 FC True-RMS Wireless Current Clamp set the new standard for technicians
in DC environments up to 1500 V. Whether you’re working with a utility-scale
solar photovoltaic (PV) array, wind power, an electric railway, or a data
center, the Fluke 283 FC has been engineered to enhance safety and increase
productivity while giving you accurate, reliable, and repeatable results.
The 283 FC/PV includes CAT III 1500 V DC safety-rated accessories so you can
work confidently in higher voltage environments without compromising safety.
Staubli MC4 test leads allow you to quickly make reliable, secure connections to
modules or strings to test DC voltage up to 1500 V DC. TL175-HV CAT III 1500
V/CAT IV 1000 V rated silicone TwistGuard™ test leads give you more flexibility
when testing voltage, millivoltage, resistance, continuity, or capacitance on
inverters, combiner boxes, PV arrays, or individual PV modules. A bright backlit
LCD screen and illuminated keypad make it easier to work in both direct and low
light conditions. The included magnetic hanging kit frees up your hands and the
custom hard carrying case protects your investment while you transport it.
CAT III 1500 V/CAT IV 1000 V Safety Rated
CAT III 1500 V
DC systems are now a standard in utility scale PV systems, offering significant
cost savings and efficiency improvements to facility owners. These systems
operate at higher voltage levels, allowing each inverter to handle more energy,
enable longer strings of connected panels, and reduce the need for additional
wiring and inverters. Consequently, standard CAT IV inverter outputs of 800 V AC
or higher are more prevalent, making it crucial to prioritize safety and
accuracy in measurements.
The CAT III 1500 V/CAT IV 1000 V rated 283 FC
multimeter and a283 FC wireless current clamp meet the safety requirements for
test equipment (IEC 61010-2-032) corresponding to the overvoltage category level
of the PV array electrical installation (IEC 61730-1). Combine these with CAT
III 1500 V/CAT IV 1000 V rated TL175-HV Premium Silicone Test Leads, CAT III
1500 V MC4 connectors and you’ve got a comprehensive frontline troubleshooting
solution that offers safe and accurate voltage measurement for troubleshooting
everything from the inverters, combiners, strings of modules, or individual
modules.
Unique Multimeter Readiness Self-Check
The size and
location of utility-scale solar sites can present unique challenges whether
they’re logistical, environmental, or testing related. Because of that, you want
to have confidence that your meter is fully functional, capturing the right data
every time so you don’t have to do the same job twice. The 283 FC features a
unique integrated multimeter readiness selfcheck, that ensures your meter is in
proper working order before you take your next reading. This quick self-check is
an additional readiness test that gives you valuable insight to the status of
your meter’s calibration, battery life availability, test lead functionality,
and AC/DC voltage measurement functionality so you can be confident that your
meter is ready to work when you are.
Features
- Highly accurate voltage measurements for precise frontline troubleshooting
- Current measurements up to 60 A AC/DC for safely troubleshooting individual strings with of modules with greater accuracy (when using a283 FC wireless current clamp)
- Visual and audio polarity indicators with on/off function help prevent accidental module wiring issues
- User-defined limit gauge helps you make quick go/no-go troubleshooting decisions
- Unique multimeter readiness self-check helps ensure your meter is ready to test
- Save and log measurements to internal memory and view them on your mobile device via Fluke ConnectTM
Specifications
AC volts | Range: 6.000 V, 60.00 V, 600.0 V, 1000 V Resolution: 0.001 V, 0.01 V, 0.1 V, 1 V |
DC volts | Range: 6.000 V, 60.00 V, 600.0 V, 1500 V Resolution: 0.001 V, 0.01 V, 0.1 V, 1 V |
DC mV | Range: 600.0 mV Resolution: 0.1 mV |
AC mV | Range: 600.0 mV Resolution: 0.1 mV |
Continuity | Range: 600 Ω Resolution: 1 Ω |
Resistance | Range: 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ,
6.000 MΩ, 50.00 MΩ Resolution: 0.1 Ω, 0.001 kΩ, 0.01 kΩ, 0.1 kΩ, 0.001 MΩ, 0.01 MΩ |
Capacitance | Range: 1000 nF, 10.00 μF, 100.0 μF, 9999 μF Resolution: 1 nF, 0.01 μF, 0.1 μF, 1 μF |
Frequency | Range: 99.99 Hz, 999.9 Hz, 9.999 kHz, 99.99 kHz Resolution: 0.01 Hz, 0.1 Hz, 0.001 kHz, 0.01 kHz |
AC VA | Range: 360.0 VA, 3.600 kVA, 36.00 kVA, 60.00 kVA Resolution: 0.1 VA, 0.001 kVA, 0.01 kVA, 0.01 kVA |
DC VA | Range: 360.0 VA, 3.600 kVA, 36.00 kVA, 90.00 kVA Resolution: 0.1 VA, 0.001 kVA, 0.01 kVA, 0.01 kVA |
Min-max avg | For DC functions, accuracy is the specified accuracy of the
measurement function ± 12 counts for changes longer than 350 ms in
duration. For AC functions, accuracy is the specified accuracy of the measurement function ± 40 counts for changes longer than 900 ms in duration. |
Environmental | |
Operating temperature | -10 °C to 60 °C |
Storage temperature | 30 °C to +70 °C |
Humidity | 0 % to 90 %, 10 °C to 30 °C 0 % to 75 %, 30 °C to 40 °C 0 % to 45 %, 40 °C to 60 °C |
General | |
Counts | 6000 |
Size | 22.5 cm x 10.5 cm x 5.7 cm (8.8 in x 4.1 in x 2.2 in) |
Weight | 0.7 kg (1.5 lb) |
Battery life | > 150 hours typical, without backlight (Alkaline, 3 AA) > 100 hours typical when connected to wireless current clamp (Alkaline, 3 AA) |