  • Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter (BC# -L/T*)
  • Alligator Clips
  • Test Leads
  • User Manual on CDROM
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

Fluke 28II EX

A rugged intrinsically safe digital multimeter engineered to stand up to harsh conditions
Whether you work in petroleum, chemical, or pharmaceutical environments, all the test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built. The 28II Ex intrinsically safe digital multimeter is ideal for use in Class 1, Div. 1 - Zone 1 and 2 (gas) areas and is also waterproof, dust-proof (IP67) and drop-proof. You'll be equipped to handle any situation, inside and outside of hazardous zones, without compromising compliance or measurement performance.

Intrinsic safety and regulatory approvals
The 28II Ex carries Ex certifications from the world’s leading certification bodies.

USA
Class I Zone 1 AEx ia IIC T4

USA and Canada
Class I, Division 1, Groups ABCD T4

28II safety compliance
IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: Measurement CAT III 1000 V / CAT IV 600V

Extreme rugedness
The Fluke 28II Ex is one of the most rugged intrinsically safe digital multimeters available
• A completely sealed, IP67 rated case
• Withstands drops up to 3 meters or 10 feet (with holster)
• Waterproof
• Dustproof
• Reversible holster for added protection of the display when not in use

Features

  • Measures up to 1000 V and 10 A ac and dc (note that Ex zones require reduced measurements)
  • Low pass filter ensures accurate voltage and frequency measurements on variable speed motor drives (VSDs)
  • Frequency to 200 kHz and % duty cycle to help you diagnose VSDs and switching power supplies
  • Resistance, continuity and diode test
  • 10,000 μF capacitance range for components and motor caps
  • Conductance measurements for high resistance or leakage tests
  • Min/Max/Avg and Peak capture to record transients and variations automatically
  • Relative mode to remove test lead interference on resistance measurements
  • Auto and manual ranging for maximum flexibility
  • Input Alert protects you by chirping and flashing “Lead” when leads are plugged into the wrong inputs

Specifications:

DC Voltage Range: 0.1 mV to 1000 V
Accuracy: ± (0.05 % + 1)
AC Voltage Range: 0.1 mV to 1000 V
Accuracy: ± (0.7 % +4)
DC Current Range: 0.1 μA to 10 A
Accuracy: ± (0.2 % + 4)
AC Current Range: 0.1 μA to 10 A
Accuracy: ± (1.0 % + 2)
Resistance Range: 0.1 Ω to 50 MΩ
Accuracy: ± (0.2 % + 1)
Conductance Range: 60.00 nS
Accuracy: ± (1.0 % + 10)
Diode test Range: 2.0 V
Accuracy: ± (2.0 % + 1)
Duty cycle Range: 0.0 % to 99.9 %
Accuracy: Within ± (0.2 % per kHz + 0.1 %) for rise times <1 µs
Display counts 6000 counts/19,999 counts in high-resolution mode
Capacitance Range: 10 nF to 9999 μF
Accuracy: ± (1.0 % + 2)
Frequency Range: 0.5 Hz to 199.99 kHz
Accuracy: ± (0.005 % + 1)
Temperature Range: -200 °C to +1090 °C (-328 °F to +1994 °F)
Accuracy: ± (1.0 % + 10) °C [± (1.0 % + 18) °F]
General Specifications
Power Three AAA batteries – type approved*
Battery life: 400 hours
Display LCD, with backlight
Data storage Peak transient capture 250 μS
External protection Rubber holster
Size 6.4 cm x 10.0 cm x 19.8 cm
(2.5 in x 3.9 in x 7.8 in)
Weight 698 g (1.54 lb)
Safety
ATEX II 2G Ex ia IIC T4 Gb I M1 Ex ia I Ma
ETL (NEC/CEC) Class I Zone 1 AEx ia IIC T4 Class I, Division 1, Groups ABCD T4 Ex ia IIC T4
IEC Ex Ex ia IIC T4 Gb Ex ia I Ma
ANZEx (Australia) Ex ia IIC T4 Gb Ex ia I Ma
PCEC Ex ia IIC T4 Gb
IEx Brazil Ex ia IIC T4 Gb
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: Measurement CAT III 1000 V / CAT IV 600V