Fluke 345 Single Phase Power Quality Clamp Meter
$1,095.00
Availability:
Out of stock
SKU
PQ24
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
Request a Quote for
- Fluke 345 Power Quality Clamp Meter (BC# 40316-L/T*)
- (2) 1000V Hard Point Test Leads
- (2) Alligator Clips
- AC Adapter/Charger
- USB PC Interface Cable
- User Manual On CD-ROM
- Carrying Case (G)
Fluke 345 Power Quality Clamp Meter
The ideal meter for commissioning and troubleshooting modern electrical loads
With a bright color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable frequency drives, electronic lighting and UPS systems. Additionally, the Hall Effect measurement system makes measurement of dc current possible without the need to break the circuit, and the internal memory enables long-term logging for analysis of trends or intermittent problems.
Log measured parameters
All voltage, current, power, and harmonic measurements can be logged for minutes, hours, or months. Measurement averaging periods from 1 second to 15 minutes can be selected depending on the application.
Measured parameters can be logged into three separate recording memory areas. If longer recordings are required, the three areas may be combined into one. Stored measurements can be recalled and displayed on-screen in normal screen format or downloaded using the Power Log software package.
Flexible and easy to use
The 345 measures a wide range of electrical parameters and can be used for many applications in todayメs modern electrical environment. Measuring mode is selected by a simple turn of the rotary switch and the large color display presents data in a clear, easy-to-understand way.
By default the display will show the most common measurements, in very large format. If more detailed views are required they are available with the press of a single key (up to six measurements at once).
Inrush current
Diagnose equipment start-ups with the inrush current mode. A current trigger level is set prior to recording. Once the level has been exceeded, the meter will begin capture. Recordings from 3 seconds to 300 seconds may be captured, and up to 1000 inrush events may be stored in the instruments memory.
Screen captures and data logging
Any measurement can be stored in memory for later viewing, or downloaded to a PC. Simply press ムSAVEメ to capture the active screen to memory ヨ up to 50 screen shots can be saved for quick and simple documentation. Additionally, over 150,000 individual measurements can be logged for later review on the display or on a PC using Power Log software.
Features:
Specifications:
Logging times
The ideal meter for commissioning and troubleshooting modern electrical loads
With a bright color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable frequency drives, electronic lighting and UPS systems. Additionally, the Hall Effect measurement system makes measurement of dc current possible without the need to break the circuit, and the internal memory enables long-term logging for analysis of trends or intermittent problems.
Log measured parameters
All voltage, current, power, and harmonic measurements can be logged for minutes, hours, or months. Measurement averaging periods from 1 second to 15 minutes can be selected depending on the application.
Measured parameters can be logged into three separate recording memory areas. If longer recordings are required, the three areas may be combined into one. Stored measurements can be recalled and displayed on-screen in normal screen format or downloaded using the Power Log software package.
Flexible and easy to use
The 345 measures a wide range of electrical parameters and can be used for many applications in todayメs modern electrical environment. Measuring mode is selected by a simple turn of the rotary switch and the large color display presents data in a clear, easy-to-understand way.
By default the display will show the most common measurements, in very large format. If more detailed views are required they are available with the press of a single key (up to six measurements at once).
Inrush current
Diagnose equipment start-ups with the inrush current mode. A current trigger level is set prior to recording. Once the level has been exceeded, the meter will begin capture. Recordings from 3 seconds to 300 seconds may be captured, and up to 1000 inrush events may be stored in the instruments memory.
Screen captures and data logging
Any measurement can be stored in memory for later viewing, or downloaded to a PC. Simply press ムSAVEメ to capture the active screen to memory ヨ up to 50 screen shots can be saved for quick and simple documentation. Additionally, over 150,000 individual measurements can be logged for later review on the display or on a PC using Power Log software.
Features:
- AC/DC current:
- Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
- Highest safety rating:
- 600 V CAT IV rated for use at the service entrance
- Accurate in noisy environments:
- Even with distorted waveforms present on electronic loads with low-pass filter
- Data logging:
- Identify intermittent faults by logging any power parameters for minutes or months, including harmonics
- Verify batteries:
- Direct measurement of dc ripple (%) for battery and dc systems
- Troubleshoot harmonics:
- Analyze and log harmonics digitally or graphically
- Inrush current:
- Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
- Easy to use:
- Easily confirm instrument setup with large backlit color display of waveforms and trends
- 3-Phase power:
- Built in capability for balanced loads
- View graphs and generate reports:
- With Power Log software
- Set up and troubleshoot variable frequency drives and UPS systems
- Verify correct operation by measuring key parameters
- Harmonics measurements
- Uncover harmonic issues that can damage or disrupt critical equipment
- Inrush capture
- Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
- Load studies
- Verify electrical system capacity before adding loads
Specifications:
Display | Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight |
Power supply | Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 |
Battery life typically | > 10 hours (backlight on full) > 12 hours (backlight reduced) |
Battery Eliminator BE345 | Input: 110 V/230 V, 50/60 Hz Output: 15 V dc, 300 mA |
Ambient conditions (For indoor use only) | |
Reference conditions | All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F) |
Operating temperature | 0 °C to 50 °C (32 °F to 122 °F) |
Temperature coefficient of current | = ± 0.15 % of rdg per °C |
Temperature coefficient of voltage | = ± 0.15 % of rdg per °C |
Maximum relative humidity | 80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at 40 °C (104 °F) |
Maximum operating altitude | 2000 m |
Electrical safety | Safety IEC 61010-1 600 V CAT IV, double or reinforced insulation, pollution degree 2 Protection IP40; EN60529 |
Maximum safe working voltages | Current measurement: 600 V ac rms or dc between uninsulated conductor and ground Voltage measurement: 600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages (delta power config.) |
EMC | |
Emission | IEC/EN 61326-1:1997 class B |
Immunity | IEC/EN 61326-1:1997 |
Mechanical | |
Dimensions (length x width x depth) | 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
Weight including batteries | 820 g/1.8 lb |
Jaw opening | 60 mm |
Jaw capacity | 58 mm diameter |
Cleaning | The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents. |
Electrical data | All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F). See Ambient conditions specifications for temperature coefficients. |
Current measurement (dc, dc rms, ac rms) | |
Measuring range | 0 to 2000 A dc or 1400 ac rms |
Autorange facility | 40 A/400 A/2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 A in 2000 A range |
Accuracy | |
DC and dc rms | I > 10 A: ± 1.5 % rdg ± 5 digits I < 10 A: ± 0.2 A |
AVG | I > 10 A: ± 3 % rdg ± 5 digits I < 10 A: ± 0.5 A |
Pk | I > 10 A: ± 5 % rdg ± 5 digits I < 10 A: ± 0.5 A |
AHr | I > 10 A: ± 2 % rdg ± 5 digits I < 10 A: ± 0.5 AHr |
CF (Crest Factor) | 1.1 = CF < 3: ± 3 % rdg ± 5 digits 3 = CF < 5: ± 5 % rdg ± 5 digits Resolution: 0.01 |
RPL (Ripple) | 2 % = RPL < 100 %: ± 3 % rdg ± 5 digits 100 % = RPL < 600 %: ± 5 % rdg ± 5 digits Resolution: 0.1 % Idc > 5 A, Iac > 2 A |
Voltage measurement (dc, dc rms, ac rms) | |
Measuring range | 0 to 825 V dc or ac rms |
Autorange facility | 4 V/40 V/400 V/750 V |
Resolution | 1 mV in 4 V range 10 mV in 40 V range 100 mV in 400 V range 1 V in 750 V range |
Accuracy | |
DC and dc rms | V > 1 V: ± 1 % rdg ± 5 digits V < 1 V: ± 0.02 V |
AVG | V > 1 V: ± 3 % rdg ± 5 digits V < 1 V: 0.03 V |
Pk | V > 1 V: ± 5 % rdg ± 5 digits V < 1 V: ± 0.03 V |
CF (Crest Factor) | 1.1 = CF < 3: ± 3 % rdg ± 5 digits 3 = CF < 5: ± 5 % rdg ± 5 digits Resolution: 0.01 |
RPL (Ripple) | 2 % = RPL < 100 %: ± 3 % rdg ± 5 digits 100 % = RPL < 600 %: ± 5 % rdg ± 5 digits Resolution: 0.1 % Vdc > 0.5 V, Vac > 0.2 V |
Harmonics | |
THD (Total Harmonic Distortion) | 1 % = THD < 100 %: ± 3 % rdg ± 5 digits 100 % = THD < 600 %: ± 5 % rdg ± 5 digits Resolution: 0.1 % |
DF (Distortion Factor) | 1 % = DF < 100 %: ± 3 % rdg ± 5 digits Resolution: 0.1 % H02 = Vharm < H13: ± 5 % rdg ± 2 digits H13 = Vharm = H30: ± 10 % rdg ± 2 digits |
Watts measurement (single- and three-phase) (dc, dc rms, ac rms) | |
Measuring range | 0 to 1650 kW dc or 1200 kW ac |
Autoranging facility | 4 kW, 40 kW, 400 kW, 1650 kW ac |
Resolution | 1 W in 4 kW 10 W in 40 kW 100 W in 400 kW 1 kW in 1200 kW |
Accuracy | 2.5 % rdg ± 5 digits W1Ø < 2 kW ± 0.08 kW W3Ø < 4 kW ± 0.25 kW |
VA measurement (single- and three-phase) (dc, dc rms, ac rms) | |
Measuring range | 0 to 1650 kVA dc or 1200 kVA ac |
Autorange facility | 4 kVA, 40 kVA, 400 kVA, 1650 kVA |
Resolution | 1 VA in 4 kVA 10 VA in 40 kVA 100 VA in 400 kVA 1 kVA in 1200 kVA |
Accuracy | |
VA > 2 kVA | 2.5 % rdg ± 5 digits |
VA < 2 kVA | ± 0.08 kVA |
VAR measurement (single- and three-phase) | |
Measuring range | 0 to 1250 kVAR |
Autorange facility | 4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR |
Resolution | 1 VAR in 4 kVAR 10 VAR in 40 kVAR 100 VAR in 400 kVAR 1 kVAR in 1200 kVAR |
Accuracy | |
VAR > 4 kVAR | ± 2.5 % rdg ± 5 digits |
VAR < 4 kVAR | ± 0.25 kVAR |
Power factor range | 0.3 < PF < 0.99 |
Power factor (single- and three-phase) | |
Measuring range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0° to 72.5° inductive) |
Resolution | 0.001 |
Accuracy | ± 3° |
Frequency range | 15 Hz to 1 kHz |
Displacement power factor | |
Measuring range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0° to 72.5° inductive) |
Resolution | 0.001 |
Accuracy | ± 3° |
Frequency range | 15 Hz to 22 Hz and 45 Hz to 65 Hz |
Kilowatt hour (kWHr) | |
Measuring range | 40,000 kWHr |
Autorange facility | 1 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr |
Resolution | 1 WHr in 4 kWHr 10 WHr in 40 kWHr 100 WHr in 400 kWHr 1 kWHr in 4,000 kWHr 10 kWHr in 40,000 kWHr |
Accuracy | |
kWHr > 2 kWHr | ± 3 % ± 5 digits |
kWHr < 2 kWHr | ± 0.08 kWHr |
All Watts /VA /VAR /PF measurements | |
Frequency range | DC and 15 Hz to 1 kHz |
Current range | 10 A to 1400 A rms |
Voltage range | 1 V to 825 V rms |
Maximum input | 825 V rms/1400 A rms |
Maximum overload | 1000 V rms/10,000 A |
Frequency measurement (from current or voltage sources) | |
Measuring range | 15 Hz to 1 kHz |
Resolution | 0.1 Hz |
Accuracy | 15 to 22 Hz ± 0.5 % rdg 40 Hz to 70 Hz ± 0.5 % rdg 15 Hz to 1000 Hz ± 1% rdg |
Current range | 10 A to 1400 A rms |
Voltage range | 1 V to 825 V rms |
Scope function | |
Current measurement | |
Ranges | 10 A/20 A/40 A/100 A/200 A/400 A/1000 A/2000 A |
Resolution | 1 A in 40 A 10 A in 400 A 50 A in 2000 A |
Accuracy | ± 3 % rdg ± 1 pixel |
Maximum overload | 10,000 A |
Voltage measurement | |
Ranges | 4 V/10 V/20 V/40 V/100 V/200 V/400 V/1000 V |
Resolution | 100 mV in 4 V 1 V in 40 V 10 V in 400 V 31.25 V in 1000 V |
Accuracy | ± 2 % rdg ± 1 pixel |
Maximum overload | 1000 V rms |
Frequency range | DC and 15 Hz to 600 Hz |
Time base | 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div |
Refresh rate | 0.5 seconds |
Maximum sampling rate | 15.625 kHz |
Inrush current function | |
Ranges | 40 A, 400 A, and 2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 A in 2000 A range |
Accuracy | |
I > 10 A | ± 5 % rdg ± 1 pixel |
I < 10 A | ± 0.5 A |
Maximum overload | Maximum overload 10,000 A or rms x frequency < 400,000 |
Capture time | 1 s, 3 s, 10 s, 30 s, 100 s, and 300 s |
Maximum sampling rate | 15.625 kHz |
Interface | USB Interface to a PC Power Log software for download, analysis, and reporting 345 Upgrade Utility for installing a new firmware version |
Logging Memory | |
Logging areas | Three areas that can be used individually or combined into one large area |
Averaging periods | 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom |
Logging times
Volts and current mode | ||
Average time | Logging time (1 area) | Logging time (3 areas) |
1 s | 1 h 49 m | 5 h 12 m |
2 s | 3 h 38 m | 10 h 24 m |
5 s | 9 h 06 m | 1 d 2 h 00 m |
10 s | 18 h 12 m | 2 d 04 h 00 m |
30 s | 2 d 06 h 36 m | 6 d 12 h 01 m |
1 min | 4 d 13 h 12 m | 13 d 00 h 03 m |
5 min | 22 d 18 h 00 m | 65 d 00 h 15 m |
10 min | 45 d 12 h 00 m | 130 d 00 h 30 m |
15 min | 68 d 06 h 00 m | 195 d 00 h 45 m |
V & A harmonics mode | ||
Average time | Logging time (1 area) | Logging time (3 areas) |
1 s | 0 h 34 m | 1 h 38 m |
2 s | 1 h 08 m | 3 h 16 m |
5 s | 2 h 52 m | 08 h 11 m |
10 s | 5 h 44 m | 16 h 23 m |
30 s | 17 h 13 m | 2 d 01 h 11 m |
1 min | 1 d 10 h 26 m | 4 d 02 h 23 m |
5 min | 7 d 04 h 10 m | 20 d 11 h 25 m |
10 min | 14 d 08 h 20 m | 81 d 0 h 50 m |
15 min | 21 d 12 h 30 m | 121 d 13 h 15 m |
single- and three-phase power mode | ||
Average Time | Logging Time (1 area) | Logging Time (3 areas) |
1 s | 1 h 40 m | 4 h 47 m |
2 s | 3 h 21 m | 9 h 34 m |
5 s | 8 h 22 m | 23 h 57 m |
10 s | 16 h 45 m | 1 d 23 h 54 m |
30 s | 2 d 02 h 17 m | 5 d 23 h 42 m |
1 min | 4 d 04 h 35 m | 11 d 23 h 25 m |
5 min | 20 d 22 h 55 m | 59 d 21 h 05 m |
10 min | 41 d 21 h 50 m | 119 d 18 h 10 m |
15 min | 62 d 20 h 45 m | 179 d 15 h 15 m |
For full Fluke 345 product specifications, please click here: Fluke 345