Fluke 3540 FC Three-Phase Power & Condition Monitor

$3,239.00
Availability: In stock
SKU
PL10

Condition: Refurbished / Calibrated

Warranty: 1 Year Warranty

Shipping: USA & Worldwide

  • Fluke 3540 FC Three-Phase Power & Condition Monitor (BC# 7625A-L/T*)
  • (3) Fluke iFlex 1500-12 Cables
  • Fluke Voltage Test Lead
  • (2) Fluke Stackable Test Leads
  • (2) Fluke Flexible
  • (6) Alligator Clips
  • Fluke DC Power Cable
  • 3540FC Quick Reference Guide
  • Application Software USB Flash Drive
  • Power Cord
  • Carrying Case (G)
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

Fluke 3540 FC Three-Phase Power Monitor

The 3540 FC Three-Phase Power Monitor is a compact device to monitor key electrical parameters at three-phase machinery (or equipment) and stream data to the Fluke Connect® Cloud. The measurement data is available on any connected device using Fluke Connect mobile app or Fluke Connect® Condition Monitoring software.

Graphs are available to show the trends and fluctuations of the measurements during the monitoring period. Alarm settings notify users immediately when measurement values are outside specified thresholds.

Monitoring the electrical parameters like current and distortion can reveal how the machinery (or equipment) is performing, for example:

  • A baseline current or load at a critical pump is trending dangerously close to the motor’s maximum current rating, taking service factor into account.
  • The total power at an induction furnace appears to be fluctuating abnormally during a curing cycle.
  • Determining how often a submersible or hydraulic pump is cycling on/off to maintain flow or pressures, in some cases simply validates their is power to the pump.

Immediate access to information about machinery performance can be the difference between preventing a production stoppage. Understanding a machines change in performance triggers the need to investigate further, the alternative is unknowingly letting the machine run to fail.

 

Measurement:

  • Single or three phase loads
  • Voltage, Current and Frequency
  • Power including Active Power (VA), Non-active power (var) and Power Factor (PF)
  • Total harmonic Distortion (%)

 

The Monitor includes a mode to log measurements when no connection to the Fluke Connect® Cloud is available. You can transfer Logged data with the Fluke Connect mobile app.

The total number of measurements depends on the selected topology (wiring configurations), like wye, delta, or split phase.

 

Specifications:

General specifications
Color LCD display 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel
Dimensions (wxhxd) 3540 FC: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
Detachable power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
3540 FC with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 4.0 in)
Weight 3540 FC: 1.1kg (2.5 lb)
Power Supply: 400 g (0.9 lb)
Tamper protection Kensington lock
Environmental specifications
Operating temperature O °C to 45 °C (32 °F to 113 °F)
Storage temperature <20 °C to +60 °C (-4 °C to +140 °F),
with battery: -20 °C to +50 °C (-4 °F to +122 °F)
Operating humidity <10 °C (<50 °F) non condensing
10 °C to 30 °C (50 °F to 86 °F) ≤95 %
30 °C to 40 °C (86 °F to 104 °F) ≤75 %
40 °C to 45 °C (104 °F to 113 °F) ≤45 %
Operating altitude 2000 m (6,500 ft) (up to 4,000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude 12,000 m (39,000 ft)
IP rating IEC 60529:IP50, in connected condition with protection caps in place
Vibration MIL-T-28800E, Type 3, Class III, Style B
Safety
IEC 61010-1 IEC mains input: Overvoltage Category II, Pollution Degree 2
Voltage terminals: Overvoltage Category IV, Pollution Degree 2
IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
Electromagnetic compatibility (EMC)
International IEC 61326-1: Industrial
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless radio with adapter
Frequency range 2412 MHz to 2462 MHz
Output power <100 mW
Single and Three Phase Topologies
Wiring configuration 1-Φ, 1-Φ IT, Split phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies)
Voltage inputs
Number of inputs 4 (3 phases and neutral)
Maximum input voltage 1000 Vrms (1700 Vpk) phase to neutral
Input impedance 10 MΩ each phase to neutral
Bandwidth 42.5 Hz to 3.5 kHz
Scaling 1:1, variable
Current inputs
Number of inputs 3, mode selected automatically for attached sensor
Current sensor output voltage Clamp: 500 mVrms / 50 mVrms; CF 2.8
Rogowski coil: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Bandwidth (-3dB) 42.5 Hz to 3.5 kHz
Scaling 1:1 and variable
Data acquisition
Resolution 16-bit synchronous sampling
Sampling frequency 10.24 kHz at 50/60Hz, synchronized to mains frequency
Input signal frequency Mains 50/60 Hz (42.5 to 69 Hz)
Data storage Internal flash memory (not user replaceable)
Memory size Typical 1 offline logging session of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements
Measured parameters Voltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF
Averaging interval 1 s
Total harmonic distortion THD for voltage and current is calculated on 25 harmonics
Calculated min/max values times
Voltage Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 HZ)
Current Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz)
Power 200 ms
Interfaces
USB-A Firmware updates, max. supply current: 120 mA
WiFi
Supported modes Direct connection and connection to infrastructure
Security WPA2-AES with pre-shared key
Power supply
Voltage range nominal 100 V to 500 V (85 V min to 550 V max) using safety plug input
Mains power nominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input
Power consumption Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Standy power <0.3 W only when powered using IEC 60320 input
Efficiency ≥ 68.2 % (in accordance with energy efficiency regulations)
Mains frequency 50/60 Hz ± 15 %
Battery power Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime Up to 4 hr (up to 5.5 hr in energy saving mode)
Charging time <6 hr

   

   

For full Fluke 3540 FC Power & Condition Monitor product specifications, please click here: Fluke 3540 FC