Fluke 373 True RMS Clamp Meter
$195.00
Availability:
Out of stock
SKU
11H57
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
Request a Quote for
- Fluke 373 True RMS AC Clamp Meter (BC# 20214-L/T*)
- 1000V Hard Point Test Leads (1-Red, 1-Black)
- User Manual On CD-ROM
- Carrying Case
Fluke 373 True RMS AC Clamp Meter
The new Fluke 373 Clamp Meter offers improved performance perfect for many ac only current measurement situations. With true-rms ac voltage and current measurements, the Fluke 373 reads up to 600 A ac and 600 V ac or dc.
Measurement Capability:
Specifications:
The new Fluke 373 Clamp Meter offers improved performance perfect for many ac only current measurement situations. With true-rms ac voltage and current measurements, the Fluke 373 reads up to 600 A ac and 600 V ac or dc.
Measurement Capability:
- 600 A ac current measurement with fixed jaw
- 600 V ac and dc voltage measurement
- True-rms ac voltage and current for accurate measurements on non-linear signals
- Resistance measurement to 6000O with continuity detection
- 1000 µF capacitance measurement
- State of the art signal processing allows for use in noisy electrical environments while providing stable readings
- Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement
- CAT IV 300 V, CAT III 600 V safety rating
Specifications:
Electrical Specifications | |
AC Current | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 2 % ± 5 digits (48 - 62 Hz) |
Crest Factor (50/60 Hz) | 2.5 @ 600 A |
AC Voltage | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 1.0 % ± 5 digits (48 ヨ 62 Hz) |
DC Voltage | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 1 % ± 5 digits |
Resistance | |
Range | 600.0 O/6000 O |
Resolution | 0.1 O/1 O |
Accuracy | 1 % ± 5 digits |
Continuity Beeper | 30 O |
Capacitance | |
Range | 10.0 ヨ 100.0 µF / 1000 µF |
Resolution | 0.1 µF/1 µF |
Accuracy | 1.9 % ± 2 digits |
Mechanical Specifications | |
Size (L x W x H) | 232 mm x 85 mm x 45 mm |
Weight | 370 g |
Environmental Specifications | |
Operating Temperature | -10 °C to +50 °C |
Storage Temperature | -40 °C to +60 °C |
Operating Humidity | Non condensing (< 10 °C) = 90 % RH (at 10 °C to 30 °C) = 75 % RH (at 30 °C to 40 °C) = 45 % RH (at 40 °C to 50 °C) (Without Condensation) |
Operating Altitude | 3000 meters |
Storage Altitude | 12,000 meters |
EMI, EMC | Meets all applicable requirements in EN61326-1:2006 |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C |
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008 |