Fluke 373 True RMS Clamp Meter

$195.00
Availability: Out of stock
SKU
11H57

Condition: Refurbished

Warranty: 1 YEAR WARRANTY

Shipping: USA & Worldwide

Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

  • Fluke 373 True RMS AC Clamp Meter (BC# 20214-L/T*)
  • 1000V Hard Point Test Leads (1-Red, 1-Black)
  • User Manual On CD-ROM
  • Carrying Case
 Fluke 373 True RMS AC Clamp Meter

The new Fluke 373 Clamp Meter offers improved performance perfect for many ac only current measurement situations. With true-rms ac voltage and current measurements, the Fluke 373 reads up to 600 A ac and 600 V ac or dc.

Measurement Capability:
  • 600 A ac current measurement with fixed jaw
  • 600 V ac and dc voltage measurement
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Resistance measurement to 6000O with continuity detection
  • 1000 µF capacitance measurement
Features:
  • State of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement
  • CAT IV 300 V, CAT III 600 V safety rating

Specifications:
Electrical Specifications
AC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2 % ± 5 digits (48 - 62 Hz)
Crest Factor (50/60 Hz) 2.5 @ 600 A
AC Voltage
Range 600.0 A
Resolution 0.1 A
Accuracy 1.0 % ± 5 digits (48 ヨ 62 Hz)
DC Voltage
Range 600.0 A
Resolution 0.1 A
Accuracy 1 % ± 5 digits
Resistance
Range 600.0 O/6000 O
Resolution 0.1 O/1 O
Accuracy 1 % ± 5 digits
Continuity Beeper 30 O
Capacitance
Range 10.0 ヨ 100.0 µF / 1000 µF
Resolution 0.1 µF/1 µF
Accuracy 1.9 % ± 2 digits
Mechanical Specifications
Size (L x W x H) 232 mm x 85 mm x 45 mm
Weight 370 g
Environmental Specifications
Operating Temperature -10 °C to +50 °C
Storage Temperature -40 °C to +60 °C
Operating Humidity Non condensing (< 10 °C)
= 90 % RH (at 10 °C to 30 °C)
= 75 % RH (at 30 °C to 40 °C)
= 45 % RH (at 40 °C to 50 °C)
(Without Condensation)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMI, EMC Meets all applicable requirements in EN61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Safety Compliance ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV
Pollution Degree 2
EN/IEC 61010-2-32:2002