Fluke 721 Dual Precision Pressure Calibrator
$2,695.00
Availability:
In stock
SKU
2C47
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke 721 Dual Precision Pressure Calibrator (BC# 42592-L/T*)
- (2) Fluke Hard Point Test Leads
- Fluke 721 Quick Reference Guide
- User Manual On CD-ROM
- Carrying Case (G)
Request a Quote for
Fluke 721 Dual Precision Pressure Calibrator
The 721 can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).
Specifications:
For full Fluke 721 specifications, please click here: Fluke 721
The 721 can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).
- Ideal for gas flow calibration (custody transfer) applications
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Pt100 RTD input for temperature measurement, (probe optional)
- Measures 4 to 20 mA signals
- Internal 24 V loop power supply can power a transmitter under test
- Measure up to 30 V dc, check 24 V loop power supplies
- Extend pressure measurement range with connection to external 700 series pressure modules (29 ranges)
- Large backlit graphic display can display up to three inputs simultaneously
- Store five instrument setups for recall and use
Specifications:
Low pressure sensor | High pressure sensor | ||||||
Model | Description | Range sensor | Resolution sensor | Accuracy sensor | Range sensor | Resolution sensor | Accuracy sensor |
Fluke-721-3630 | Dual Sensor Pressure Calibrator, 36 PSIG, 3000 PSIG | -14 psi to +36 psi -0.97 bar to 2.48 bar | 0.001 psi, 0.0001 bar | 0.025% of full scale | 0 psi to +3000 psi 0.00 bar to 200 bar | 0.1 psi 0.01 bar | 0.025% of full scale |
General specifications | |
Instrument setup recall | Last used on power-up |
Environmental | Operating temperature -10 °C to +50 °C Storage temperature (without batteries) -20 °C to +60 °C |
Altitude | 2,000 meters |
Ingress protection | IP-40 |
Power requirements | 6.0 v dc |
Battery life | >35 hours, typical usage |
Batteries required | (4) Standard AA cells |
Dimentions (HxWxD) | 7.9” X 4.3” X 2.3” (20 cm X 11 cm X 5.8 cm |
Weight | 03539 kg (1 lb 3 oz) |
Connectors/ports pressure | Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe |
Electrical and temperature measurement 1-year | |||
Function | Range | Resolution | Accuracy |
mA measure | 0 to 24 mA | 0.001 mA | ±0.015% of rdg ±0.002mA |
VDC measure | 0 to 30 VDC | 0.001V | ±0.015% of rdg ±0.002V |
Temperature measure (RTD/ Ohms) | -40 °C to 150 °C (-40 °F to 302 °F) | 0.01 °C, 0.01 °F | ±0.015% of rdg ±0.02 ohms; ±0.1°C (±0.2°F) ±0.25 degC (±0.45 degF) combined uncertainty when using 720 RTD probe accessory |
Loop power supply | 24V | N/A | 24 mA @ 24V |
Temperature effect |
No effect on accuracy on all functions from 15 °C to 35 °C |
Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C |
For full Fluke 721 specifications, please click here: Fluke 721