Fluke 80i-110s side

Fluke 80i-110s AC/DC Clamp-On Current Probe

Fluke 724 Temperature Calibrator

$1,999.00
Availability: In stock
SKU
2C04

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Shipping: USA & Worldwide

  • Fluke 724 Temperature Calibrator (BC# 42845-L/T*)
  • (2) 1000V Hard Point Test Leads
  • User Manual On CD-ROM
  • Carrying Case (G)
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

Built for the masters of temperature.

The new Fluke 724: everything you need to troubleshoot and calibrate temperature.

  • Now you can carry one tool to expertly test all the temperature sensors and transmitters in your plant.
  • The Fluke 724 is the masterメs answer to temperature calibration. The Fluke 724 can measure and source 10 thermocouple types and 7 RTD types, plus volts and ohms.
  • The Fluke 724 even handles high-speed pulsed RTD circuits and provides loop power.
  • The dual line measure/source display lets you source temperature and view loop current at the same time.
  • With its simple, モno menusヤ controls, the Fluke 724 is easy to operate, too.

Feel the Heat!
The new Fluke 724 Temperature Calibrator is a powerful yet easy-to-use calibrator. Use the measure and source functions to test and calibrate almost any temperature instrument.

  • Easy to read dual display lets you view input and output simultaneously
  • Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters
  • Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters
  • Perform fast linearity tests with 25% and 100% steps
  • Execute remote tests with auto step and auto ramp
  • Power transmitters during test using loop power supply with simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Compact, streamlined shape makes it easy to carry
  • Rugged, reliable design stands up to field use
  • Backlight lets you work in poor light
  • Large battery capacity of four AA cells
  • Battery door for easy changes

Measurement Accuracy
Voltage DC
30.000 V  0.02%+ 2 counts (upper display)
20.000 V  0.02%+ 2 counts (lower display)
100.00 mV  0.02%+ 2 counts
-10.00 mV to 75.00 mV  0.025 % + 1 count (via TC connector)
Current DC
24.000 mA  0.02%+ 2 counts
Resistance
0.0 to 400.0 O  0.1O (4-wire), 0.15O (2- and 3-wire)
401 to 1500 O  0.5O (4-wire), 1O (2- and 3-wire)
1500 to 3200 O  1O (4-wire), 1.5O (2- and 3-wire)

Source Accuracy
Voltage DC
100.00 mV  0.02%+2 counts
10.000 V  0.02%+2 counts
-10.00 mV to 75.00 mV  0.025 % + 1 count (via TC connector)
Resistance
15.0 to 400.0 O  0.15 O (exc. current 0.15 to 0.5 mA), 0.1 O (exc. current 0.5 to 2 mA)
401 to 1500 O  0.5 O(excitation current 0.05 to 0.8 mA)
1500 to 3200 O  1 O(excitation current 0.05 to 0.4 mA)

RTDs and Thermocouples
Measure Accuracy:
NI-120  0.2 °C
PT-100 (385)  0.33 °C
PT-100 (393)  0.3 °C
PT-100 (JIS)  0.3 °C
PT-200 (385)  0.2 °C
PT-500 (385)  0.3 °C
PT-1000 (385)  0.2 °C
Resolution:  0.1 °C
J:  0.7 °C
K:  0.8 °C
T:  0.8 °C
E:  0.7 °C
R:  1.8 °C
S:  1.5 °C
B:  1.4 °C
L:  0.7 °C
U:  0.75 °C
N:  0.9°C
Resolution  J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B, R, S: 1 °C, 1 °F
XK  0.6°C
BP  1.2°C
Source Accuracy:
NI-120  0.2 °C
PT-100 (385)  0.33 °C
PT-100 (393)  0.3 °C
PT-100 (JIS)  0.3 °C
PT-200 (385)  0.2 °C
PT-500 (385)  0.3 °C
PT-1000 (385)  0.2 °C
Resolution:  0.1 °C
Note:  Accuracy stated for 4-wire measurement.
J:  0.7 °C
K:  0.8 °C
T:  0.8 °C
E:  0.7 °C
R:  1.4 °C
S:  1.5 °C
B:  1.4 °C
L:  0.7 °C
U:  0.75 °C
N:  0.9 °C
Resolution  J, K, T, E, L, N, U: 0.1 °C, B, R, S: 1 °C
XK  0.6°C
BP  1.2°C

Specifications
Ramp Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Ramps  Slow ramp, Fast ramp, 25% step-ramp
Loop Power Function
Voltage:  24V
Accuracy:  10%
Maximum current:  22 mA, short circuit protected
Step Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Steps  25% of range, 100% of range

Environmental Specifications
Operating Temperature
 -10ºC to 55ºC
Storage Temperature
 -20ºC to 71ºC
Humidity (Without Condensation)
90%  10ºC to 30ºC
75%  30ºC to 40ºC
45%  40ºC to 50ºC
35%  50ºC to 55ºC

Safety Specifications
Safety Rating
 CSA C22.2 No. 1010.1:1992
EMC
 EN50082-1:1992 and EN55022:1994 Class B

Mechanical & General Specifications
Size
 96 x 200 x 47 mm
Weight
 650 g
Batteries
 Four AA alkaline batteries.
Battery Life
 25 hours typical
Shock & Vibration
 Random, 2G, 5-500 Hz



For full Fluke 724 specifications, please click here: Fluke 724