Fluke 729 300G FC Automatic Pressure Calibrator

Fluke 729 300G FC Automatic Pressure Calibrator

Fluke 729 30G FC Automatic Pressure Calibrator 30 psi / 2.0 bar

$5,819.00
Availability: Out of stock
SKU
2C75

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

Fluke 729 30G FC Pressure Calibrator

Portable automatic pressure calibrator simplifies pressure calibration

The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a timeconsuming task, but the 729 makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package.

The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment control automatically stabilizes the pressure at the requested value.

The Fluke 729 can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. The 729 does the rest.

Built-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration and the ability to adjust to applied 0 % and 100 % values.

Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.

With three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them.

 

Automatic pressure generation and control to 300 psi, (20 bar, 2 MPa). Enter a pressure and the 729 automatically pumps to the desired pressure. Fill in a test template and the 729 will automatically pump to and document a multiple-point pressure calibration test.

 

Easy calibration documentation using defined templates for transmitters and switches. Type in the starting and ending test pressures and number of test points. The 729 does the rest by documenting the applied pressure, measured mA and % error for each test point. The bright color graphical display will flag out of tolerance test results in red.

 

Automatic internal fine pressure adjustment helps compensate for minor leaks in hoses and test setups. No need to manually turn a vernier to compensate for leaks helping to eliminate the hassle of manual pumping and manual fine adjustment of test setups.

 

HART communication enables mA output trim, trim to applied values and pressure zero trimming of HART pressure transmitters. You can also do light configuration tasks such as changing a transmitter tag, measurement units and ranging. Other supported HART commands include setting fixed mA outputs for troubleshooting, read device configuration and variables and read device diagnostics.

 

Measure mA signals on transmitter outputs, source and simulate mA signals for testing I/Ps and other mA loop devices. Includes a 24V loop power supply for testing and powering transmitters in standalone tests disconnected from the control system.

 

Rugged portable design and 3-year warranty set the 729 apart from most other pressure calibrators. The 729 is tested and warranted to withstand a 1-meter drop test so it is ready for field instrumentation calibration work.

 

Fluke Connect® compatibility enables a user to perform remote monitoring using the Fluke Connect mobile app and also manage and store pressure measurements and logging events. Share measurements using ShareLive™ video calls and emails.

 

Measure pressure with legacy 700 Series and the new 750 Series pressure modules if different pressure measurement ranges or resolution is desired.

 

Multiple language support, select language from the instrument setup utility. Hart communication commands are limited to English per the HART device descriptors and protocol.

 

Features:

  • Automatic pressure generation and regulation to 300 psi
  • Easily document the process using onboard test templates
  • Automatic internal fine-pressure adjustment
  • Measure, source and simulate 4 to 20 mA signals
  • 24V loop power for powering transmitters for tests
  • Bright dual/triple-channel color graphical display
  • HART communication for testing HART smart transmitters
  • Built in leak testing for verifying test setups for leakage
  • Fluke Connect® App compatibility
  • Measure Vdc for testing 1 V dc to 5 V dc output transmitters
  • Compatible with 700 Series and 750 Series pressure modules

 

Specifications:

Pressure specification
One-year specification 0.02 % of full scale
Control specification 0.005 % full scale minimum
Psi range, resolution -12.0000 to 30.0000 psi
Bar range, resolution -0.82737 to 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
Electrical specification
(All specifications are valid to 110 % of range, except 24 mA source and simulate which are valid to 100 % of range)
Ranges
mA measure, source and simulate 0 mA to 24 mA
Volts dc measure 0 V dc to 30 V dc
Resolution
mA dc source, simulate and measure 1 μA
Voltage dc measurement 1 mV
Accuracy 0.01 % ± 2 LSD all ranges (at 23 °C ± 5 °C)
Stability 20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C
Loop compliance voltage 24 V dc @ 20 mA
mA simulate external voltage requirement 12 V dc to 30 V dc
Temperature measurement only/100 Ω Pt(385) RTD -50 °C to 150 °C (-58 °F to 302 °F)
Temperature resolution 0.01 °C (0.01 °F)
Temperature accuracy ± 0.1 °C (0.2 °F) ± 0.25 °C (± 0.45 °F) combined uncertainty
Drive capability 1200 Ω without HART resistor, 950 Ω with internal HART resistor
General specifications
Mechanical specification
Mechanical specification Size (HxWxL) 7 cm x 27.94 cm x 17.27 cm (2.75 in x 11 in x 6.8 in)
Weight 6.5 lbs., 2.95 kg
Ingress protection IP54
Environmental specification
Operating temperature -10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control
Operating temperature with battery -10 °C to 40 °C (Battery will only charge to 40 °C )
Storage temperature -20 °C to 60 °C
Operating altitude 3000 m
Storage altitude 13000 m

 

For full Fluke 729 30G product specifications, please click here: Fluke 729 30G

Fluke 729 30G FC Automatic Pressure Calibrator

Designed specifically with process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results

Includes Carrying Case & Accessories As Listed

Fluke 729 30G FC Automatic Pressure Calibrator Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry

 

BC# -L/T* 

  • Fluke 729 30G FC Automatic Pressure Calibrator (BC# -L/T)
  • Test Leads
  • User Manual On CD-ROM
  • AC Adapter/Charger
  • Carrying Case