Fluke 753 Documenting Process Calibrator
$5,419.00
Availability:
In stock
SKU
2C33
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke 753 Documenting Process Calibrator (BC# 36300-L/T*)
- Fluke 700TLK Deluxe Test Lead Kit:
- Deluxe Carrying Case w/ Shoulder Strap
- Fluke AC280 Hook Clips
- TP220 Fluke Test Probes
- Stackable Test Lead Sets
- Extended Tooth Alligator Clips
- USB PC Interface Cable
- AC Adapter/Charger
- Power Cord
- User Manual On CD-ROM
- Carrying Case (G)
Request a Quote for
Fluke 753 Documenting Process Calibrator
Whether youメre calibrating instruments, troubleshooting a problem or running routine maintenance, Fluke 750 Series process calibrators can help you get the job done faster. It does so many different tasks, so quickly and so well, itメs the only process calibrator you need to carry.
Features:
For full Fluke 753 product specifications, please click here: Fluke 753
Whether youメre calibrating instruments, troubleshooting a problem or running routine maintenance, Fluke 750 Series process calibrators can help you get the job done faster. It does so many different tasks, so quickly and so well, itメs the only process calibrator you need to carry.
- Multifunctional
- Calibrate temperature, pressure, voltage, current, resistance, and frequency. Since it both measures and sources, you can troubleshoot and calibrate all with one rugged tool
- Powerful, yet easy to use
- The easy-to-follow, menu-driven display guides you through any task. Programmable calibration routines enable you to create and run automated as-found/as-left procedures to ensure fast, consistent, calibrations.
- Records and documents results
- To support your ISO-9000 or regulatory standards, the Fluke 753, and 754 capture your calibration results, eliminating the need to juggle a pen and pad in the field. The USB interface in the Fluke 753 and 754 lets you transfer the results to a PC, thus saving the time of having to manually transcribe them when you return to the shop.
- Truly hand-held
- Small enough to fit easily into a tool bag and to use in tight spaces. Runs an entire shift on a rechargeable Li-ion battery pack.
- Rugged and reliable
- Overmolded urethane case stands up to rough handling in industrial environments.
- Bright white display
- lets you read your results in any kind of light. Backlight has three (3) settings.
- Soft keys
- Provide one-touch access to enhanced functions such as task lists, automated procedures, scaling, min/max, stepping and ramping, andreview memory.
- Three operating modes
- Measure, Source, or simultaneous Measure/Source, ラenable technicians to troubleshoot, calibrate, or maintain instrumentation with just one tool
- Use it immediately
- If youメve used the Fluke 74X Documenting Process Calibrator youメll be able to pick up the 75X and start using it immediately, without a learning curve.
- Multi-lingual interface
- Displays instructions in English, French, German, Spanish, and Italian
- AutoStep
- Allows technicians to set the calibrator for a delayed start and a specific sequence of steps, so it can run unattended as a continuously varying test source.
- User entered values
- Enable users to capture readings measured or sourced by other devices
- Custom units
- Allow readings to be scaled and displayed in any user-defined units.
- Switch calibration procedures
- Perform fast, automated calibration of one- and two-point switches for voltage, current, temperature, and pressure.
- Differential pressure flow instrument calibration
- routines use a square root function to directly calibrate DP flow instruments.
- Built-in algebraic calculator
- With four functionsラplus square rootラstores, recalls, and performs calculations required for setting up instruments or evaluating data in the field. Use it to set the source function to a calculated value. Thereメs no need to carry a pencil and paper or a separate calculator.
- Programmable measurement delay
- inside automated procedures permits calibrating instruments that respond slowly
Features:
- Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
- Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Power transmitters during test using loop supply with simultaneous mA measurement
- Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
- Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
- Holds up to a full week of downloaded procedures and calibration results.
- Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
- Easy to use
- Bright white dual display. Read both sourced and measured parameters simultaneously.
- Multi lingual interface
- Rechargeable Li-Ion battery for 10 hour uninterrupted use.
- Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
- Compatible with many Asset Management software packages.
Measurement Accuracy | ||
Voltage DC | ||
Range /Resolution | 1 Year | 2 Years |
100.000 mV | 0.02% + 0.005 mV | 0.03% + 0.005 mV |
3.00000 V | 0.02% + 0.00005 V | 0.03% + 0.00005 V |
30.0000 V | 0.02% + 0.0005 V | 0.03% + 0.0005 V |
300.00 V | 0.05% + 0.05 V | 0.07% + 0.05 V |
Voltage AC | ||
3.000 V (40 Hz to 500 Hz) / 0.001 V | 0.5% + 0.002 V | 1.0% + 0.004 V |
30.00 V (40 Hz to 500 Hz) / 0.01 V | 0.5% + 0.02 V | 1.0% + 0.04 V |
300.0 V (40 Hz to 500 Hz) / 0.1 V | 0.5% + 0.2 V | 1.0% + 0.2 V |
Current DC | ||
30.000 mA | 0.01% + 5 uA | 0.015% + 7 uA |
110.00 mA | 0.01% + 20 uA | 0.015% + 30 uA |
Resistance | ||
10.000 O | 0.05% + 50 mO | 0.07% + 70 mO |
100.00 O | 0.05% + 50 mO | 0.07% + 70 mO |
1.0000 kO | 0.05% + 500 mO | 0.07% + 0.5 O |
10.000 kO | 0.1% + 10 O | 0.15% + 15 O |
Frequency | ||
1.00 to 110.00 Hz / 0.01 Hz1.00 to 110.00 Hz / 0.01 Hz | 0.05 Hz | |
110.1 to 1100.0 Hz / 0.1 Hz | 0.5 Hz | |
1.101 to 11.000 kHz / 0.001 kHz | 0.005 kHz | |
11.01 to 50.00 kHz / 0.01 kHz | 0.05 kHz | |
Technical Data | ||
Data log functions |
Measure functions | Voltage, current, resistance, frequency, temperature, pressure |
Reading rate | 1, 2, 5, 10, 20, 30, or 60 readings/minute | |
Maximum record length | 8000 readings (7980 for 30 or 60 readings/minute) | |
Ramp functions |
Source functions | Voltage, current, resistance, frequency, temperature |
Rate | 4 steps/second | |
Trip detect | Continuity or voltage (continuity detection not available when sourcing current) | |
Loop power function |
Voltage | Selectable, 26 V |
Accuracy | 10%, 18 V minimum at 22 mA | |
Maximum current | 25 mA, short circuit protected | |
Maximum input voltage | 50 V DC | |
Step functions |
Source functions | Voltage, current, resistance, frequency, temperature |
Manual step | Selectable step, change with arrow buttons | |
Autostep | Fully programmable for function, start delay, stepvalue, time per step, repeat | |
Environmental Specifications | ||
Operating temperature | -10°C to +50°C | |
Storage temperature | -20°C to +60°C | |
Dust/water resistance | Meets IP52, IEC 529 | |
Operating altitude | 3000 m above mean sea level (9842 ft) | |
Safety Specifications | ||
Agency approvals | CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 | |
Mechanical and General Specifications | ||
Size | 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) | |
Weight | 1.2 kg (2.7 lb) | |
Batteries | Internal Battery Pack Li-ion: 7.2 V, 4400 mAh, 30 Wh | |
Battery life | > 8 hours typical | |
Battery replacement | Via snap-shut door without opening calibrator; no tools required | |
Side port connections | Pressure module connector USB Connector to interface to your PC Connection for optional battery charger/eliminator |
|
Data storage capacity | 1 week of calibration procedures results |
For full Fluke 753 product specifications, please click here: Fluke 753