Fluke 773 Milliamp mA Process Clamp Meter
$899.00
Availability:
In stock
SKU
10H15
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke 773 Milliamp Process Clamp Meter (BC# 42210-L/T*)
- (2) 1000V Hard Point Test Leads
- User Manual On CD-ROM
- Carrying Case (G)
Request a Quote for
Fluke 773 Milliamp Process Clamp Meter
If you need more time in your busy day take a good look at the Fluke 773 mA Clamp Meters. Itメs designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.
The 773 mA Clamp Meter features:
- Best in class 0.2% accuracy
- 0.01 mA resolution and sensitivity
- Measure 4 to 20 mA signals without モbreaking the loopヤ
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
- Measure 4 to 20 mA signals with in-circuit measurement
- Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
- Source 4 to 20 mA signals for testing control system I/O or I/Ps
- mA output linear ramp or 25% step output
- DC voltage measurement to verify 24V power supplies or voltage I/O signals
- Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
- Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
- Enables milliamp signal logging to a separate logging device without breaking the loop
- Output mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loop
- mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
- Apply a mA input signal to a device and measure itsメ 4-20 mA output on devices such as valves or mA isolators
- Voltage output linear ramp or 25% step output
- Automatically change the voltage output for remote testing
Measure mA signals for PLC and control system analog I/O without breaking the loop
- Measures low level dc current
- Correlate process indication with real physical value
Measure output signals from transmitters without breaking the loop
- Maintain and troubleshoot process and automation equipment without breaking the loop
- No disruption to the process
Detachable clamp with extension cable
- Measurements in tight locations
- Enables measurements in difficult situations
Measurement Spotlight
- Illuminates hard to see wires in dark enclosures
- Measurement process is easier and quicker
Measure up to 99.9 mA range non-contact
- Wide range of measurements
- Measures 10 to 50 mA signals in older control systems
Automatic power off
- After 15 minutes and 2 minute automatic off for backlight and spotlight
- Saves battery life
Specifications | ||
Diameter of measurable conductor | 0.177" or 4.5 mm max | |
Operating temperature | -10 to 50ºC | |
Storage temperature | -25 to 60ºC | |
Operating humidity | < 90% @ <30ºC, < 75% @ 30 to 55ºC | |
Operating altitude | 0 to 2000 m | |
IP rating | IP 40 | |
Size | 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) | |
Weight | 410 g, (14.4 oz) | |
Vibration | Random 2 g, 5 to 500 Hz | |
Shock | 1 meter drop test (except the jaw) | |
EMI/RFI | Meets EN61326-1 | |
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. | ||
Temperature coefficient | 0.01% ºC (< 18ºC or > 28ºC) |
|
Power, battery life | (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms | |
Warranty | Three years for electronics One year for cable and clamp assembly |
|
Functional Specifications | ||
mA measurement (measured by clamp) |
Resolution / range | 0 to 20.99 mA |
Accuracy | 0.2% + 2 counts | |
Resolution / range | 21.0mA to 100.0 mA | |
Accuracy | 1% + 5 counts | |
mA measurement (measured in series with test jacks) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
mA source (maximum mA drive: 24 mA into 1,000 ohms) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
mA simulate (maximum voltage 50 V dc) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
Voltage source (2 mA maximum drive current) | Resolution / range | 0 to 10.00 V DC |
Accuracy | 0.2% + 2 counts | |
Voltage measure | Resolution / range | 0 to 30.00 V DC |
Accuracy | 0.2% + 2 counts |
For full Fluke 773 specifications, please click here: Fluke 773