Fluke 77 IV 1000V Industrial Digital Multimeter
$295.00
Availability:
In stock
SKU
10H22
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke 77IV Digital Multimeter (BC# 37848-L/T*)
- (2) 1000V Hard Point Test Leads
- User Manual On CD-ROM
- Carrying Case (G)
Request a Quote for
Fluke 77IV Digital Multimeter
Versatile meters for field service or bench repair
The NEW Fluke 77-IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke’s original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that’s easier to view.
It measures:
- Wide 1000 V measurement range
- Average responding ac measurements
- 0.3 % accuracy
- 20 A for 30 seconds
- Frequency and capacitance
- Resistance and continuity
Specifications:
Maximum voltage between any terminal and earth ground | 1000 V |
Surge protection | 8 kV peak per IEC 61010 |
Fuse for mA input | 440 mA, 1000 V FAST Fuse |
Fuse for A input | 11 A, 1000 V FAST Fuse |
Display | Digital: 6,000 counts, updates 4/sec |
Bar graph | 33 segments, updates 32/sec |
Frequency | 10,000 counts |
Capacitance | 1,000 counts |
Operating altitude | 2,000 meters |
Storage altitude | 12,000 meters |
Operating temperature | -10 °C to + 50 °C |
Storage temperature | -40 °C to + 60 °C |
Electromagnetic compatibility (EN 61326-1:1997) | In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F) |
Relative humidity (maximum non-condensing) | 90 % to 35 °C; 75 % to 40 °C; 45 % to 50 °C |
Battery life | 400 hours typical (Alkaline) |
Size (H x W x L) | 4.3 cm x 9 cm x 18.5 cm |
Weight | 420 g |
Safety compliance | ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV |
Certifications | CSA, TÜV (EN61010), UL, ∏, (N10140), VDE |
Function | Range | Resolution | Accuracy |
AC volts (average responding) | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
2.0 % + 2 (45 Hz to 1 kHz) |
DC mV | 600.0 mV | 0.1 mV | 0.3 % + 1 |
DC volts | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.3 % + 1 |
Continuity | 600 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper turns off at > 250 Ω; detects opens or shorts of 250 µs or longer. |
Ohms | 600.0 Ω 6.000 kΩ 60.00 kΩ 600.0 kΩ 6.000 MΩ 50.00 MΩ |
0.1Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 1 |
Diode test | 2.400 V | 0.001 V | 1 % + 2 |
Capacitance | 1000 nF 10.00 µF 100.0 µF 9999 µF |
1 nF 0.01 µF 0.1 µF 1 µF |
1.2 % + 2 |
AC Amps (average responding) | 60.00 mA 400.0 mA 6.000 A 10.00 A |
0.01 mA 0.1 mA 0.001 A 0.01 A |
2.5 % + 2 (45 Hz to 1 kHz) |
DC amps | 60.00 mA 400.0 mA 6.000 A 10.00 A |
0.01 mA 0.1 mA 0.001 A 0.01 A |
1.5 % + 2 |
Hz (ac voltage input) | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
0.1 % + 1 |
MIN MAX AVG | For dc functions, accuracy is the specified accuracy of the measurement function (12 counts for changes longer than 275 ms in duration. For ac functions, accuracy is the specified accuracy of the measurement function (40 counts for changes longer than 1.2 s in duration. |