Hioki 3196 kit with accessories

Hioki 3196 Three 3 Phase Power Quality Analyzer w/ 9661 Clamp-On Sensors

Fluke 43 kit with accessories

Fluke BT521 Advance Battery Analyzer 0.09% + 5 Accuracy BT 521

Fluke 80T-IR Handheld Infrared Temperature Probe 0°F to 500°F

$99.95
Availability: Out of stock
SKU
IR17

Condition: Refurbished

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

Fluke 80T-IR Infrared Temperature Probe


The Fluke 80T-IR Infrared Temperature Probe (the probe) is a noncontact temperature measurement accessory for use with a test instrument capable of measuring DC volts in the millivolt range such as a digital multimeter (DMM). The probe has a temperature range of -18°C to 260°C (0°F to 500°F), with a basic accuracy of 3% of reading, and an output of 1 mV dc per °C or °F. Temperature is measured by pointing the probe at the surface to be measured, and reading the temperature on the test instrument display.

Emissivity
All objects emit invisible infrared energy. This ability, called emissivity, is based upon the material that the object is made of and its surface finish. Emissivity values typically range from 0.10 for a very reflective object to 0.98 for a near perfect black body. The probe senses this energy assuming that the target has an emissivity value of 0.95. This value is factory set in the probe. If the actual target emissivity is less than 0.95, the indicated temperature could be less than the actual target surface temperature. To correct for this, apply masking tape or a coat of matte paint to the target. The resulting target will have an emissivity of approximately 0.95.

Distance to Spot Size Ratio
Distance to Spot Size Ratio (or Field of View) refers to the diameter of the spot that the probe is sensing at a given distance. The closer you are to the object (or target), the smaller the area (or spot) the probe is sensing. For example when the probe is held at a 200 mm (8 in.) distance from the target, the spot size is approximately 50 mm (2 in.)

Measurement Considerations:
• If the surface to be measured is small (13 mm (1/2 in.) or less), hold the probe as close as possible to the surface (no more than 50 mm (2 in.) away).
• If the surface to be measured is covered by frost or other material, clean it to expose the surface.
• If the surface to be measured is highly reflective such as polished metal, apply masking tape or a matte finish paint to the surface.
• If the probe seems to be giving incorrect readings check the front of the probe. There may be condensation or debris obstructing the sensor; clean per instructions in the maintenance section.

Quick Check
For a quick check of the probe, point it directly at ice immersed in water (slush), the meter should read, within specifications limits, 0°C (32°F) (see Accuracy specifications).


Specifications
Temperature Range -18 to 260°C (0 to 500°F)
Ambient Operating Range: 0 to 63°C (32 to 145°F)
TemperatureCoefficient: ±0.2% of reading or ±0.2°C (±0.3°F), whichever is greater, change in accuracy per °C change in ambient operating temperature above 28°C (82°F) or below 18°C (64°F).
Response Time: 1 second
Spectral Response: 8 to 14 microns nominal
Emissivity: pre-set 0.95
Output: 1 mV/degree °C or °F
Relative Humidity: 95% RH or less @ 30°C (86°F) noncondensing, Temp. Coef. applies
Storage Temperature: -25 to 70°C (-13 to 158°F) without battery
Power: 9V battery; (NEDA 1604A, 6F22, 006P)

 

For full Fluke 80T-IR Temperature Probe product specifications, please click here: Fluke 80T-IR

Fluke 80T-IR Infrared Temperature Probe

The Fluke 80T-IR has a temperature range of -18°C to 260°C (0°F to 500°F), with a basic accuracy of 3% of reading

This Non-Contact Temperature Probe Has a 1 Second Response Time

Fluke 80T-IR 80T IR Infrared Thermometer Temperature ProbeModels On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 9416B

  • Fluke 80T-IR Infrared Temperature Probe (BC# 9416B)