Fluke 190M-4 kit with accessories

Fluke 190M-2 2 Channel 200 MHz Medical ScopeMeter

Fluke 97 Auto Scopemeter Dual Trace 50 MHz Handheld Oscilloscope

$895.00
Availability: Out of stock
SKU
11H111

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

Fluke 97 AUTO Spec Table

Fluke 97 Auto Scopemeter


Your Fluke 97/Auto ScopeMeter combines the capabillities of a dual-trace, digital-storage oscilloscope with teh versatility of a digital multimeter. This combination allows you to analyze and compare complex waveforms, read voltage levels, or simply measure resistances.

ScopeMeter features include:
- Dual Trace, 50-MHz Bandwidth Scope
- 25 million samples-per-second, 40 ns glitch capture capability
- 3000 Count Digital Multimeter (DMM)
- Menu-Driven Interface for easy operation.
- Storage for 10 front panel setups (Meter and Scope Modes).
- Digital starage for eight waveforms.
- Simultaneous display of four waveforms (any combination of live and stored) allows for useful comparisons.
- Autoset configures ScopeMeter to select the best voltage and time base settings for a meaningful display.
- Undo featrue allows you to step back through the 10 most recent key presses.
- true portability and three source choices allow for testing in real-life environments.


Specifications
Multimeter
DC Volt
Ranges: 300 mV, 3V, 30V and 300V
Accuracy: ±0.5% ±5 counts
AC Volt
Ranges: 300 mV, 3V, 30V and 250V
Accuracy: ±1% ±10 coutns, 50 Hz to 50 Hz
±2% ±15 coutns, 20 Hz to 20 kHz
±3% ±20 coutns, 5Hz to 1 MHz
additonal error
±1% ±1 kHz
For <10Hz with 10:1 probe or >100 Hz direct (1:1 probe), use function Vrms AC + V DC.
The 10:1 accessory probe increases the ranges by a factor of 10.
To create more accurate measurements on ac, or on dc with a large ac component, the time base often can be optimized by pressing "auto-set" or by changing the settign accessed by pressing "Time"

mV DC
Ranges: 300 mV and 3V
Accuracy: ±0.5% ±5 counts
This range has a low-pass filter with a bandwidth of 5 kHz.
Ω Ohm Ranges:
Ranges: 300Ω, 3kΩ, 30kΩ, 300 kΩ, 3 MΩ and 30MΩ
Accuracty: ±0.5% ±5 counts
Range: 30Ω
Accuracty: ±2.4% ±25 counts
Diode
Measuring Current: 0.5mA
Maximum Voltage: 4V
If Output Voltage is higher than 2.8V, OL (OverLoad) is displayed.
Display Modes
Frequency
The Frequency can be displayed withing the following parameters:
Range: 1 Hz...5MHz
Accuracy: ±0.5%
Resolution: 4 Digits
Trace DISP
The display trace can be switched off.
Duty%+, Duty%-
Relative on-to-off time of a varying input can be displayed as a percentage.
Range: from <2.0% to >98.0% for signal amplitudes >10% of the input voltage range.
Resolution: 0.1%
Accuracy (logic or pulse waveforms): within ±0.5%
Accuracy (sine or triangle waveforms): within ±1% + ((Voltage Range/RMS Input Voltage) x 1%)
%/Delta                              
Displays the difference after 0% or % is pressed.
Scaling
0% and 100% can be set, creating an a + bx computed reading where a and b are the 0 and 100% values, respectively, and x is the measured value.
Volt Match
Results can be displayed in dBV, dBm, dBW, or Audio Watt. The assumed load resistance can be chosen from: 1,2,4,8,16,50,60,75,93,110,125,135,150,200,250,300,500,600,800,900,1000,1200 Ω, depending on teh display mode.
Record
In meter mode, the actual value is displayed simultaneously with the maximum, average, and minimum values.
Tough Hold Feature
Can be activated by pressing "Hold Run"
Oscilloscope
Vertical System
Deflection Factor
1mV to 100V per division in 1-2-5 sequence, for time base 60s/division to 1ms/division. This can be expanded by a factor of 10 witht eh 10:1 accessory probe.
Vertical Resolution
8 bits, 25 levels per division
DC Accuracy
±2%
Rise Time
Vertical amplifier response limits the rise time to 7ns. For time base settigns slower than 200ns teh rise time is smaller than the sample distance, so the measured rise time is unreliable if it is smaller than (2xs/div)/25
Bandwidth
With 10:1 prove only:> MHZ (-3dB)
Nonlinearity
Including analing to digital converter, which will have no missing codes and is monotonic: ±)2% ± 1 digit)
Move Control Range
From +4 divisions to -4 divisions
DC Balance
Base line is automatically readjusted after switching the attenuator or ac/dc/ground
MIN/MAX
Acquisition mode at 1 ms per division or slower on Channel A only. Pulse width for 100% probability of detection is 40ns.
Average
The running average can be set to 256 maximum. In Roll Mode, the average is fixed at 10.
Zoom
Expand or contract view centered around the 4th division, withing teh limits of the time base and teh maximum dleay.
Horizontal System
Range: 5s to 10ns per division with triggered start.
The roll mode is active from 60s to 10s
Single shots are possible from 5s to 100 ns per division
For tiem base settings faster than 1ms, an automatic interpolation takes place. The useful band-width is about 6MHz.
For time base settings of 50ms or slower, the channels are chopped.
for time base settigns of 20ms or faster, teh channels are alterneated. Channel A is dipslayed first and, after a second trigger pulse, Channel B is diplayed second.
ACCURACY:
Accuracy is ±0.1% 1 LSB
Sample Frequency
Dependent on time base:
25/sec-per-div) Hz (maximum 25 MHz)
in Min/Max: 25 MHz
Record Length
512 samples calibrated for 25 samples per division.
Capture
Allows selection of a record length of 10 or 20 divisions
Move Control
From +4 divisions to -16.5 divisions.
A Versus B
Channel A is displayed along the vertical axis. The time base is set manually.
Trigger
Internal Sensitivity
For frequencies lower than 10MHz: <0.8 div
Extra amplification in the vertical system allows for 2 mV and 1 mV per division for the input signal, but not for the trigger. Therefore, sensitivity at 2mV adn 1 mV decreases by a factor of 5.
Level Range
From +4 division to -4 divisions.
External
TTL Compatible. Selectable for 0.2V or 2V.
Trigger level is indicated on the screen.
Delay Range
Time Delay: -20 to +640 divisions
Events: 1 to 1023
N_CYCLE: trigger frequency divided by N (2 to 255.)
Waevform Memories
For waveform storage, eight extra memories are avialable. The memories can be cleared all together.
Each memory contains 412 words for waveform and the setup belonging to this waveform.

Fluke 97/Auto ScopeMeter, Dual Trace, 50-MHz Bandwidth HandHeld Oscilloscope

Simultaneous display of four waveforms (any combination of live and stored) allows for useful comparisons.

Autoset configures ScopeMeter to select the best voltage and time base settings for a meaningful display.

Includes Carrying Case & Accessories As Listed


Fluke 97 Auto Scopemeter 97-Scopemeter Handheld Oscilloscope Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

 

BC# 44137-L/T*

  • Fluke 97/Auto ScopeMeter 50MHz Oscilloscope (BC# 44137-L/T*)
  • (3) Fluke Ground Leads
  • (4) Fluke Test Probes
  • (4) Fluke Alligator Clips
  • (1) Fluke BNC Clip Cable
  • (2) Coax to BNC Cables
  • Fluke Inductive Pickup
  • AC Adapter/Charger
  • Hard Carrying Case