Fluke 97 Auto Scopemeter Dual Trace 50 MHz Handheld Oscilloscope
$895.00
Availability:
Out of stock
SKU
11H111
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Request a Quote for
Fluke 97 Auto Scopemeter
Your Fluke 97/Auto ScopeMeter combines the capabillities of a dual-trace, digital-storage oscilloscope with teh versatility of a digital multimeter. This combination allows you to analyze and compare complex waveforms, read voltage levels, or simply measure resistances.
ScopeMeter features include:
- Dual Trace, 50-MHz Bandwidth Scope
- 25 million samples-per-second, 40 ns glitch capture capability
- 3000 Count Digital Multimeter (DMM)
- Menu-Driven Interface for easy operation.
- Storage for 10 front panel setups (Meter and Scope Modes).
- Digital starage for eight waveforms.
- Simultaneous display of four waveforms (any combination of live and stored) allows for useful comparisons.
- Autoset configures ScopeMeter to select the best voltage and time base settings for a meaningful display.
- Undo featrue allows you to step back through the 10 most recent key presses.
- true portability and three source choices allow for testing in real-life environments.
Specifications |
|
Multimeter |
|
DC Volt |
Ranges: 300 mV, 3V, 30V and 300V Accuracy: ±0.5% ±5 counts |
AC Volt |
Ranges: 300 mV, 3V, 30V and 250V Accuracy: ±1% ±10 coutns, 50 Hz to 50 Hz ±2% ±15 coutns, 20 Hz to 20 kHz ±3% ±20 coutns, 5Hz to 1 MHz additonal error ±1% ±1 kHz |
For
<10Hz with 10:1 probe or >100 Hz direct (1:1 probe), use function
Vrms AC + V DC. The 10:1 accessory probe increases the ranges by a factor of 10. To create more accurate measurements on ac, or on dc with a large ac component, the time base often can be optimized by pressing "auto-set" or by changing the settign accessed by pressing "Time" |
|
mV DC |
Ranges: 300 mV and 3V Accuracy: ±0.5% ±5 counts This range has a low-pass filter with a bandwidth of 5 kHz. |
Ω Ohm Ranges: |
Ranges: 300Ω, 3kΩ, 30kΩ, 300 kΩ,
3 MΩ and 30MΩ Accuracty: ±0.5% ±5 counts Range: 30Ω Accuracty: ±2.4% ±25 counts |
Diode |
Measuring Current: 0.5mA Maximum Voltage: 4V |
If
Output Voltage is higher than 2.8V, OL (OverLoad) is displayed. |
|
Display Modes |
|
Frequency |
The Frequency can be displayed
withing the following parameters: Range: 1 Hz...5MHz Accuracy: ±0.5% Resolution: 4 Digits |
Trace DISP |
The display trace can be
switched off. |
Duty%+, Duty%- Relative on-to-off time of a varying input can be displayed as a percentage. |
Range: from <2.0% to
>98.0% for signal amplitudes >10% of the input voltage range. Resolution: 0.1% Accuracy (logic or pulse waveforms): within ±0.5% Accuracy (sine or triangle waveforms): within ±1% + ((Voltage Range/RMS Input Voltage) x 1%) |
%/Delta
|
Displays the difference after 0%
or % is pressed. |
Scaling |
0% and 100% can be set, creating
an a + bx computed reading where a and b are the 0 and 100% values,
respectively, and x is the measured value. |
Volt Match |
Results can be displayed in dBV,
dBm, dBW, or Audio Watt. The assumed load resistance can be chosen
from:
1,2,4,8,16,50,60,75,93,110,125,135,150,200,250,300,500,600,800,900,1000,1200
Ω, depending on teh display mode. |
Record |
In meter mode, the actual value
is displayed simultaneously with the maximum, average, and minimum
values. |
Tough Hold Feature |
Can be activated by pressing
"Hold Run" |
Oscilloscope |
|
Vertical System | |
Deflection Factor |
1mV to 100V per division in
1-2-5 sequence, for time base 60s/division to 1ms/division. This can be
expanded by a factor of 10 witht eh 10:1 accessory probe. |
Vertical Resolution |
8 bits, 25 levels per division |
DC Accuracy |
±2% |
Rise Time |
Vertical amplifier response
limits the rise time to 7ns. For time base settigns slower than 200ns
teh rise time is smaller than the sample distance, so the measured rise
time is unreliable if it is smaller than (2xs/div)/25 |
Bandwidth |
With 10:1 prove only:> MHZ
(-3dB) |
Nonlinearity |
Including analing to digital
converter, which will have no missing codes and is monotonic: ±)2% ± 1
digit) |
Move Control Range |
From +4 divisions to -4 divisions |
DC Balance |
Base line is automatically
readjusted after switching the attenuator or ac/dc/ground |
MIN/MAX |
Acquisition mode at 1 ms per
division or slower on Channel A only. Pulse width for 100% probability
of detection is 40ns. |
Average |
The running average can be set
to 256 maximum. In Roll Mode, the average is fixed at 10. |
Zoom |
Expand or contract view centered
around the 4th division, withing teh limits of the time base and teh
maximum dleay. |
Horizontal System |
|
Range: | 5s to 10ns per division with
triggered start. The roll mode is active from 60s to 10s Single shots are possible from 5s to 100 ns per division |
For tiem
base settings faster than 1ms, an automatic interpolation takes place.
The useful band-width is about 6MHz. For time base settings of 50ms or slower, the channels are chopped. for time base settigns of 20ms or faster, teh channels are alterneated. Channel A is dipslayed first and, after a second trigger pulse, Channel B is diplayed second. |
|
ACCURACY: |
Accuracy is ±0.1% 1 LSB |
Sample Frequency |
Dependent on time base: 25/sec-per-div) Hz (maximum 25 MHz) in Min/Max: 25 MHz |
Record Length |
512 samples calibrated for 25
samples per division. |
Capture |
Allows selection of a record
length of 10 or 20 divisions |
Move Control |
From +4 divisions to -16.5
divisions. |
A Versus B |
Channel A is displayed along the
vertical axis. The time base is set manually. |
Trigger |
|
Internal Sensitivity |
For frequencies lower than
10MHz: <0.8 div Extra amplification in the vertical system allows for 2 mV and 1 mV per division for the input signal, but not for the trigger. Therefore, sensitivity at 2mV adn 1 mV decreases by a factor of 5. |
Level Range |
From +4 division to -4 divisions. |
External |
TTL Compatible. Selectable for
0.2V or 2V. Trigger level is indicated on the screen. |
Delay Range |
Time Delay: -20 to +640 divisions Events: 1 to 1023 N_CYCLE: trigger frequency divided by N (2 to 255.) |
Waevform Memories |
For waveform storage, eight
extra memories are avialable. The memories can be cleared all together. Each memory contains 412 words for waveform and the setup belonging to this waveform. |
Fluke 97/Auto ScopeMeter, Dual Trace, 50-MHz Bandwidth HandHeld Oscilloscope
Simultaneous display of four waveforms (any combination of live and stored) allows for useful comparisons.
Autoset configures ScopeMeter to select the best voltage and time base settings for a meaningful display.
Includes Carrying Case & Accessories As Listed
Fluke 97 Auto Scopemeter 97-Scopemeter Handheld Oscilloscope Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 44137-L/T*
- Fluke 97/Auto ScopeMeter 50MHz Oscilloscope (BC# 44137-L/T*)
- (3) Fluke Ground Leads
- (4) Fluke Test Probes
- (4) Fluke Alligator Clips
- (1) Fluke BNC Clip Cable
- (2) Coax to BNC Cables
- Fluke Inductive Pickup
- AC Adapter/Charger
- Hard Carrying Case