Fluke 975 AirMeter Air Quality Meter w/ Velocity Probe

$1,389.00
Availability: In stock
SKU
PC04

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Shipping: USA & Worldwide

  • Fluke Networks 975 AirMeter Indoor Air Monitor (BC# 41319-L/T*) 
  • Fluke 975 Velocity Probe
  • Calibration Cap
  • Rubber Tubing
  • AC Adapter/Charger
  • USB PC Interface Cable
  • Hard Copy User Manual
  • Hard Carrying Case
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

 Fluke 975 AirMeter
The Fluke 975 AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld tool. The Fluke 975 AirMeter test tool makes indoor air quality testing easier and faster.

Use the Fluke 975 AirMeter test tool to:
  • Respond to comfort-related calls from occupants
  • Verify the operation of building HVAC control systems
  • Determine whether adequate ventilation exists
  • Monitor air flow and velocity
  • Test for dangerous carbon monoxide leaks
  • Perform duct traversals
Features:
  • Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
  • One-touch air flow and velocity with available probe
  • Wet bulb and dew point temperature
  • % of outside air calculation
  • CO2 and CO field calibration feature
  • Self-test function at startup
  • Auto-backlight
  • Automatically compensates for barometric pressure changes
  • Min/Max/Average on all measured and calculated readings
  • Multi-language user interface
  • Metric or standard units
  • Audible and visual threshold alarms
  • Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
  • Keypad lock for security
Specifications:
Feature Range Display resolution Accuracy
Measured specifications
Temperature -20 °C to 50 °C (-5 °F to 122 °F) 0.1 °F (0.1 °C) ± 0.9 °C/± 1.62°F from 40 °C to 50 °C
± 0.5 °C/± 1.00°F from 5 °C to 40 °C
± 1.1 °C/± 1.98 °F from -20 °C to 5 °C
Relative humidity 10 % to 90 % RH non-condensing 1 % ± 2 % RH (10 % RH to 90 % RH)
Air velocity 0.50 fpm to 3000 fpm
0.25 m/sec to 15 m/sec
1 fpm (0.005m/sec) ± 4% or 4 fpm*
± 4 % or 0.02 m/sec* whichever is greater
*Accuracy specification only valid for velocity readings above 50 fpm
CO2 0 to 5000 ppm 1 ppm Warm up time 1 min (5 minutes for full specification) 2.75 % + 75 ppm
CO 0 to 500 ppm 1 ppm ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH
Calculated specifications
Dew point temperature -44 °C to 50 °C (-47 °F to 122 °F) 0.1 °C (0.1 °F) ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %
± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
Wet bulb temperature -16 °C to 50 °C (3 °F to 122 °F) 0.1 °C (0.1 °F) ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 50 °C
± 2.1 °C when RH: 10 % to 20 %
Volume flow rate (in a duct) 0 to 3,965 M3/m
(0 to 140,000 cfm)
0.001 M3/min (1 cfm) N/A: The volume flow calculation will be a simple average of the data points times the duct area
% outside air (based on temperature) 0 to 100 % 0.1 % N/A
% outside air (based on CO2) 0 to 100 % 0.1 % N/A
General specifications
Operating temperature: CO and CO2 sensors -20 °C to 50 °C (-4 °F to 122 °F)
Operating temperature: All other functions -20 °C to 50 °C (-4 °F to 122 °F)
Storage temperature -20 °C to 50 °C (-4 °F to 122 °F)
Humidity 10 % to 90 % (non-condensing)
Altitude Up to 2000 m (6562 ft)
Shock and vibration MIL-PRF-28800F: Class 2
Multi-language interface English, French, Spanish, Portuguese and German
Battery Rechargeable Li-Ion (primary), three-AA (backup)
Data logging 25,000 records (continuous), 99 records (discrete)



For full Fluke 975V product specifications, please click here: Fluke 975V