The Fluke Automotive ScopeMeter® test tool is a powerful instrument with a wide variety of capabilities.
Safety
The ScopeMeter test tool has been designed and tested in accordance with IEC Publication 1010, Safety Requirements for Electronic Measuring Apparatus. This manual contains information and warnings that must be followed by the user to ensure safe operation and to keep the instrument in a safe condition. Use of this equipment in a manner not specified by the manufacturer may impair protection provided by the equipment.
Environmental Data
The environmental data mentioned in this manual are based on the results of the manufacturer's verification procedures.
Engine Tests
The Fluke Automotive ScopeMeter® test tool is a powerful instrument with a wide variety of capabilities.
- Its menu-driven interface has automatic configurations for most of your tests, so you will find that the test tool is easy to use.
- Continuous AUTO RANGE, an exclusive Fluke feature, constantly acquires and displays the best possible signal.
- The secondary ignition pickup and automated ignition functions make it easy for you to analyze an ignition system malfunction.
- The Relative Compression mode helps you quickly find a low compression cylinder.
- The Secondary Ignition Single function displays the waveform along with the spark voltage, RPM, burn time and burn voltage.
- The Intermittent Record function can find and display such a problem. This record function can record up to 1280 divisions of continuous information.
- The Flight Record function records screen snapshots from 200ms per division up to full time base speed.
- The Plot Readings function allows you to plot up to four different readings of a signal over time with a single connection.
- Min/Max Trendplot continuously monitors the minimum, maximum, and average value of a signal's readings with time stamp.
Safety
The ScopeMeter test tool has been designed and tested in accordance with IEC Publication 1010, Safety Requirements for Electronic Measuring Apparatus. This manual contains information and warnings that must be followed by the user to ensure safe operation and to keep the instrument in a safe condition. Use of this equipment in a manner not specified by the manufacturer may impair protection provided by the equipment.
Environmental Data
The environmental data mentioned in this manual are based on the results of the manufacturer's verification procedures.
Engine Tests
- RPM
- 600 - 15,000 RPM, 1 RPM resolution <1000 RPM, 10 RPM resolution >1000 RPM
- Dwell Range
- Degree: 0 to 360°, 1° resolution Milliseconds: 0 to 1,000 ms (1 ms resolution) Percentage: 0% - 100%, resolution 3 digits
- Timing Advance (TDC)
- in degrees (°) crankshaft rotation
Primary Voltage | 0 to 300V |
Secondary Voltage | 0 to 80 kV |
Burn Time | 0.6 ms to 5 ms |
Burn Voltage | 0 to 80 kV |
Relative Compression | 0 to -100% contribution |
Alternator Ripple Voltage | 0 to 300V |
Battery Condition Test | 0 to 40V |
Fuel Injection Pulse Width | 0 to 1800 ms |
Systems Automatically Tested: | Saturated Driver Conventional Throttle Body Injection Systems Current Controlled Peak And Hold Pulse Modulated |
Automated Sensor Tests | |
The Sensors menu gives direct access to a wide variety of sensor measurements. The best operating mode is automatically selected. A few of the sensors tested automatically include: | Mass Air Flow Sensor (MAF) Manifold Absolute Pressure (MAP) Oxygen Sensor (Zirconium and Titanium) Dual Oxygen Sensor Temperature Sensors Position Sensors Camshaft Position Exhaust Gas Recirculation (EGR) Ride Height Sensors Magnetic Sensors Speed Sensors Knock Sensors Distributor Triggering |
Air/fuel Systems Tested: | Mixture Control (Feedback) Frequency Control Valve (CIS E) Air Flow Meter Idle Air Compensation Exhaust Gas Recirculation (EGR) |
Electrical System Tests | Battery Condition Test Charging Diode Test Field Control Ripple Voltage Measurement Cranking Voltage Reference And Ground Voltage Drop Clamping Diode Solenoid Tests Stepper Motor |
Continuous AutoRange | Hands-off signal probing. Continuously tracks input signals from 4 Hz to 5 MHz and automatically selects the proper time base, input range, trigger level, trigger slope, and trigger source. |
40 ns Glitch detect | Sweep speeds 1 ms per division or slower. |
Vertical | |
Frequency Response, -3 dB . | DC to > 5 MHz with Filter Adapter DC to > 2.5 kHz |
AC coupled | <10 Hz direct |
Coupling | AC, DC |
Sensitivity | 5 mV to 100 V/div |
Modes | A, -A, B, -B |
Input Impedance | 1 M//55 pF direct, 10 M//4 pF with Filter Adapter |
Vertical Resolution | 8 bit (256 levels) |
Accuracy | ±(2% +1 Pixel) |
Horizontal | |
Modes | Recurrent, Single Shot, Roll |
Recurrent | 20 s to 1 s/div Dual input alternating: 1 s to 20 s/div Dual input chopped: 50 s to 1 s/div |
Single Shot | 1 s to 200 ms/div |
Roll | 500 ms to 60 s/div |
Dual input chopped | 20 s to 60 s/div |
Accuracy | ± (0.1% + 1 pixel |
Record Length. | 512 samples (20 divisions) |
Trigger | |
Sources. | A, B or TRIGGER (external) |
Sensitivity: A or B. | <0.5 div to 1 MHz <1.5 div to 5.5 MHz |
Sensitivity: TRIGGER. | +0.2V and 2.0V (TTL level compatible) |
External Input Impedance. | 1.5 M//40 pF direct |
Delay Time | -1 div |
DC Voltage | |
Ranges | direct input with STL90 leads ..... 100 mV, 300 mV, 1V, 3V, 10V, 30V, 100V, 300V |
Accuracy | ±(0.5% +5 counts) |
Full Scale Reading. | 1000 or 3000 counts |
Normal Mode Rejection. | >50 dB at 50 or 60 Hz |
Common Mode Rejection | >100 dB at DC, 50, 60, or 400 Hz |
AC or AC+DC True RMS Voltage | |
Ranges | direct input: 100 mV, 300 mV, 1V, 3V, 10V, 30V, 100V, 250V |
Accuracy (valid from 5% range). | 50 Hz to 60 Hz (1% +10 counts) .20 Hz to 20 kHz (2% +15 counts) 5 Hz to 1 MHz (3% +20 counts) |
Full Scale Reading. | 1000 or 3000 counts |
Crest Factor | Automatic ranging on crest factor overload |
Common Mode Rejection Ratio | >60 dB, DC to 60 Hz |
Frequency | 1 Hz to 5 MHz |
Resolution | 4 digits |
Accuracy | ±(0.5% +2 counts) |
RPM | selectable: n pulses/720°. |
Resolution | 4 digits |
Range. | 600 RPM to 5,000 RPM |
Accuracy | ±(1% +5 counts) |
Duty Cycle | |
Range. | 2.0% to 98.0% |
Accuracy (logic or pulse waveforms) | ±(0.5% +2 counts) |
Pulse Width | |
Range: | 250 µs to 50 ms |
Resolution | 3 digits |
Accuracy | ±(0.5% +2 counts) |
General Specifications | |
Functional on These Engine Types: | |
Number of Cylinders | 1, 2, 3, 4, 5, 6, 8 |
Engine Stroke | 2 or 4 stroke |
Fuel Types | Gasoline, Diesel |
Ignition Systems | Conventional, DIS, Coil-on-Plug |
Electrical System Voltages | 6, 12, 24V (Use gasoline settings for alternative fuel tests) |
Display | |
Type | Foil Compensated Super Twisted Liquid Crystal |
Size | 84 x 84 mm (4.7" diagonal) |
Resolution | 240 x 240 pixels |
Contrast | User adjustable |
Backlight | Cold Cathode Fluorescent (CCFL) Tube |
High Brightness | 50 cd/m2 |