Fluke ESA612 Electrical Safety Analyzer 115V ac
$1,729.00
Availability:
In stock
SKU
MT06
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke ESA612 115 VAC Electrical Safety Analyzer (BC# 34235-L/T*)
- (2) 1000V Hard Point Test Leads
- Power Cord
- USB PC Interface Cable
- Hard Copy User Manual
- Carrying Case (G)
Request a Quote for
Fluke Networks ESA612 Electrical Safety Analyzer
The ESA612 Electrical Safety Analyzer represents the next generation in testers for biomedical professionals that perform field service on medical equipment throughout their facilities, in clinics, and anywhere onsite service is required. Portable, lightweight, and designed for operation in tight spaces, the ESA612 offers the functionality of a simulator, multimeter and electrical-safety analyzer in a single test tool.
With selection of two test loads, this versatile product can be used worldwide to test to preventative maintenance electrical safety standards of choice: ANSI/AAMI ES1:1993 (NFPA-99), IEC62353 (VDE 751), and AN/NZS 3551.
The versatility of the multifaceted ESA612 is further expanded with optional automation software, which speeds and simplifies testing and provides high-end-analyzer productivity at software-level investment. Ansur-automated ESA612 standardizes test procedures, compares results to standards limits, and generates and stores reports for total digital data management.
Features:
Specifications:
For full Fluke ESA612 product specifications, please click here: Fluke ESA612
The ESA612 Electrical Safety Analyzer represents the next generation in testers for biomedical professionals that perform field service on medical equipment throughout their facilities, in clinics, and anywhere onsite service is required. Portable, lightweight, and designed for operation in tight spaces, the ESA612 offers the functionality of a simulator, multimeter and electrical-safety analyzer in a single test tool.
With selection of two test loads, this versatile product can be used worldwide to test to preventative maintenance electrical safety standards of choice: ANSI/AAMI ES1:1993 (NFPA-99), IEC62353 (VDE 751), and AN/NZS 3551.
The versatility of the multifaceted ESA612 is further expanded with optional automation software, which speeds and simplifies testing and provides high-end-analyzer productivity at software-level investment. Ansur-automated ESA612 standardizes test procedures, compares results to standards limits, and generates and stores reports for total digital data management.
Features:
- Portable, ergonomic, lightweight and easy to use
- Large, easy-to-read display with adjustable contrast
- Human-factors-designed user interface
- Bail design for stand-up testing in field environments
- Five applied parts jacks and easy ECG snap connection with optional expander box
- ECG waveform tests and dual-lead measurements combine the functionality of a simulator, multimeter and electrical-safety analyzer in a single test tool
- Replaceable mains fuses keep the device in the field and out of the repair shop
- Internal memory for 100 test records
- 20 A at 120 V current capability
- USB connection for use with Ansur and Data Viewer software (for memory download to PC)
- Optional Ansur automation software standardizes test procedures, compares results to standards limits, generates/stores reports and provides total digital data management
- Rigorously tested for rugged field applications, with CE and CSA in addition to the Fluke-quality-design stamp of approval
Specifications:
Voltage | |
Range (mains voltage) | 90 V ac to 132 V ac rms |
Range (accessible voltage) | 0 V ac to 300 V ac rms |
Accuracy | ± (2 % of reading + 0.2 V) |
Voltage tests | Mains, accessible, and point-to-point |
Earth resistance | |
Mode | Two terminal |
Test current | > 200 mA ac |
Range | 0 W to 2 W |
Accuracy | ± (2 % of reading + 0.015 W) |
Resistance tests | Earth resistance and point-to-point |
Equipment current | |
Mode | AC rms |
Range | 0 A to 20 A |
Accuracy | ± 5 % of reading + (2 counts or 0.2 A, whichever is greater) |
Duty cycle | 15 A to 20 A, 5 min on/5 min off 10 A to 15 A, 7 min on/3 min off 0 A to 10 A continuous |
Leakage current | |
Modes Modes are available in all leakage tests with the exception of MAP leakages that are available only in true-rms |
AC + DC (true-rms) AC only DC only |
Patient load selection (input impedance) |
AAMI ES1-1993 IEC 60601 |
Crest factor | = 3 |
Ranges | 0 µA to 199.9 µA 200 µA to 1999 µA 2 mA to 10 mA |
Frequency response/accuracy DC to 1 kHz 1 kHz to 100 kHz 100 kHz to 1 MHz |
± (1 % of reading + (1 µA or 1 LSD, whichever is greater)) ± (2 % of reading + (1 µA or 1 LSD, whichever is greater)) ± (5 % of reading + (1 µA or 1 LSD, whichever is greater)) |
Leakage tests | Ground wire (earth) Chassis (enclosure) Lead to ground (patient) Lead to lead (patient auxiliary) Lead isolation (mains on applied part) Direct equipment Direct applied part Alternative equipment Alternative applied part Point to point |
Mains on applied part test voltage | 100 % of mains |
Differential leakage | |
Ranges | 10 µA to 199 µA 200 µA to 2000 µA 2 mA to 20 mA |
Accuracy | ± 10 % of reading + (2 counts or 20 µA, whichever is greater) |
Insulation resistance | |
Ranges | 0.5 MW to 20 MW 20 MW to 100 MW |
Accuracy | ± (2 % of reading + 0.2 MW) ± (7.5 % of reading + 0.2 MW) |
Source test voltage | 500 V dc 250 V dc |
Insulation resistance tests | Mains-PE, AP-PE, Mains- PE, Mains-NE (non-earthed accessible conductive part) and AP- NE (non-earthed accessible conductive part) |
ECG performance waveforms | |
Accuracy | ± 2 % ± 5 % for amplitude of 2 Hz square wave only, fixed at 1 mV Lead II configuration |
Waveforms ECG complex (BPM) Ventricular fibrillation Square wave (50 % duty cycle) (Hz) Sine wave (Hz) Triangle wave (Hz) Pulse (63 ms pulse width) |
30, 60, 120, 180, and 240 0.125 and 2 10, 40, 50, 60, and 100 2 30 BPM and 60 BPM |
Power ratings | |
Mains voltage outlet | 120 V ac or 230 V ac |
Mains voltage inlet power range | 90 to 132 V ac rms 180 to 264 V ac rms |
Maximum current | 20 A 16 A |
Hz | 50 or 60 50 or 60 |
Environmental specifications | |
Operating temperature | 10 °C to 40 °C (50 °F to 104 °F) |
Storage temperature | -20 °C to 60 °C (-4 °F to 140 °F) |
Operating humidity | 10 % to 90 % non-condensing |
Altitude | 120 V ac mains supply voltage up to 5,000 m |
For full Fluke ESA612 product specifications, please click here: Fluke ESA612