Fluke ESA620 115 VAC Electrical Safety Analyzer

$3,699.00
Availability: In stock
SKU
MT10

Condition: Refurbished

Warranty: 1 YEAR WARRANTY

 Fluke ESA620 Electrical Safety Analzyer
The ESA620 Electrical Safety Analyzer, featuring smart technology to enhance productivity under any standard, represents the next generation in portable electrical safety testers. With selections of three test loads, two protective earth test currents and two insulation test voltages, this versatile device performs all primary electrical safety tests as well as several additional leakage tests for premium standards compliance worldwide.

A convenient 20 A device receptacle broadens the range of equipment that can be tested using the ESA620. Standard 2-wire and optional 4-wire protective earth measurement capabilities offer first-rate time savings, while new DSP technology offers better accuracy of leakage measurements throughout specified ranges.

Equipped with ten unique safety-enhanced ECG posts, the ESA620 offers simulation of ECG and performance waveforms so both electrical safety and basic tests on patient monitors can be performed with a single connection. When combined with optional Ansur computer-based software, the ESA620 allows for test procedure automation, the capture of results and comparison to standard limits, printed reports, and total digital data management.

Features:
  • Superior compliance with multiple standards: IEC60601:2005, EN62353, VDE 751, ANSI/AAMI ES1:1993, NFPA-99, AN/NZS 3551, IEC61010
  • Three test loads
  • Expanded leakage ranges through 10,000 µA
  • Dual-lead resistance, leakage, and voltage tests
  • AC only, dc only and true-rms leakage readings
  • 100 % and 110 % mains voltage for mains on applied part (lead isolation) test
  • 200 mA and 25 A ac PE test current
  • DSP filter technology for improved accuracy in leakage measurements
  • 20 A equipment current
  • More applied parts selections
  • ECG and performance waveforms
  • Intuitive user interface
  • Easy-to-use applied parts (ECG) connections
  • Insulation posts on applied parts connections
  • Five different insulation tests
  • Varying insulation test voltage 500 V dc and 250 V dc
  • USB connection
  • CE, C-TICK and CSA for USA and Canada
  • RoHS compliance
  • Designed, tested, and built to incomparable Fluke quality standards

Specifications:
Voltage
Range (mains voltage) 90 V to 132 V ac rms
180 V to 264 V ac rms
Range (accessible voltage) 0 V to 300 V ac rms
Accuracy ± (2 % of reading +2 LSD)
Voltage tests Mains, accessible, and point-to-point
Earth resistance
Two-terminal mode test current/range and accuracy > 200 mA ac 0.0 to 2.0 O ± (2 % of reading + 0.015 O)
10 A to 25 A ac 0.0 to 0.2 O ± (2 % of reading + 0.015 O)
0.2 to 2.0 O ± (5 % of reading + 0.015 O)
Four-terminal mode test current/range and accuracy > 200 mA ac 0.0 to 2.0 O ± (2 % of reading + 0.005 O)
10 A to 25 A ac 0.0 to 0.2 O ± (2 % of reading + 0.005 O)
0.2 to 2.0 O ± (5 % of reading + 0.005 O)
Resistance tests Earth resistance and point-to-point
Equipment current
Mode AC rms
Range/accuracy 0 A to 20 A ± 5 % of reading ± (2 counts or .2 A, whichever is greater)
Duty cycle 15 A to 20 A, 5 min on/5 min off
10 A to 15 A, 7 min on/3 min off
0 A to 10 A continuous
Leakage current
Modes AC + DC (True-rms)
AC only
DC only
Patient load selection (input impedance) AAMI ES1-1993
IEC 60601
IEC 61010
Crest factor = 3
Ranges 0 µA to 199.9 µA
200 µA to 1999 µA
2 mA to 10 mA
Frequency response/accuracy DC to 1 kHz
1 kHz to 100 kHz
100 kHz to 1 MHz
± (1 % of reading + 1 µA)
± (2 % of reading + 1 µA)
± (5 % of reading + 1 µA)
Leakage tests Earth (ground wire)
Chassis (enclosure)
Patient (lead to ground)
Patient auxiliary (lead to lead)
Mains on applied part (lead isolation)
Direct equipment
Direct applied part
Alternative equipment
Alternative applied part
Accessible
Point to point
Mains on applied part test voltage 110 % of mains at 230 V for IEC 60601
100 % of mains for AAMI at 115 V per AAMI
100 % of mains at 230 V per 62353
Differential leakage
Ranges 10 µA to 199 µA
200 µA to 1999 µA
2 mA to 20 mA
Accuracy ± 10 % of reading ± (2 counts or 20 µA, whichever is greater)
Insulation resistance
Ranges/accuracy 0.5 MO to 20 MO ± (2 % of reading + 2 counts)
20 MO to 100 MO ± (7.5 % of reading + 2 counts)
Source test voltage 500 V dc
250 V dc
Insulation resistance tests Mains-PE, AP-PE, Mains- PE, Mains-NE (non-earthed accessible conductive part) and AP- NE (non-earthed accessible conductive part)
Mamimum load capacitance 1 µF
ECG performance waveforms
Accuracy ± 2 %
± 5 % for amplitude of 2 Hz square wave only, fixed at 1 mV Lead II configuration
Waveforms ECG complex (BPM) 30, 60, 120, 180, and 240
Ventricular fibrillation
Square wave (50 % duty cycle) (Hz) 0.125 and 2
Sine wave (Hz) 10, 40, 50, 60, and 100
Triangle wave (Hz) 2
Pulse (63 ms pulse width) 30 and 60
Power ratings
Mains voltage outlet 120 V ac 230 V ac
Mains voltage inlet power range 90 to 132 V ac rms 180 to 264 V ac rms
Maximum current 20 A 16 A
Hz 50 or 60 50 or 60
Physical case
Dimensions (L x W x H) 31 cm x 23 cm x 10 cm (12.2 in x 9 in x 2.9 in)
Weight 4.7 kg (10.25 lb)
Environmental specifications
Operating temperature 10 °C to 40 °C
Storage temperature -20 °C to 60 °C
Operating humidity 10 % to 90 % non-condensing
Altitude To 2,000 meters




For full Fluke ESA620 product specifications, please click here: Fluke ESA620

Fluke ESA620 115 VAC Electrical Safety Analyzer

With selections of three test loads, two protective earth test currents and two insulation test voltages, this versatile device performs all primary electrical safety tests as well as several additional leakage tests for premium standards compliance worldwide

Superior compliance with multiple standards: IEC60601:2005, EN62353, VDE 751, ANSI/AAMI ES1:1993, NFPA-99, AN/NZS 3551, IEC61010

Includes Carrying Case & Accessories As Listed

ESA-620 ESA 620

Fluke ESA620 ESA 620 Electrical Safety Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 26234-L/T*

  • Fluke ESA620 115 VAC Electrical Safety Analyzer (BC# 26234-L/T*)
  • (2) 1000 Hard Point Test Leads
  • Power Cord
  • USB PC Interface Cable
  • User Manual On CD-ROM
  • Carrying Case (G)
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!