Fluke ESA620 115 VAC Electrical Safety Analyzer
$3,619.00
Availability:
In stock
SKU
MT10
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke ESA620 115 VAC Electrical Safety Analyzer (BC# 26234-L/T*)
- (2) 1000 Hard Point Test Leads
- Power Cord
- USB PC Interface Cable
- User Manual On CD-ROM
- Carrying Case (G)
Request a Quote for
Fluke ESA620 Electrical Safety Analzyer
The ESA620 Electrical Safety Analyzer, featuring smart technology to enhance productivity under any standard, represents the next generation in portable electrical safety testers. With selections of three test loads, two protective earth test currents and two insulation test voltages, this versatile device performs all primary electrical safety tests as well as several additional leakage tests for premium standards compliance worldwide.
A convenient 20 A device receptacle broadens the range of equipment that can be tested using the ESA620. Standard 2-wire and optional 4-wire protective earth measurement capabilities offer first-rate time savings, while new DSP technology offers better accuracy of leakage measurements throughout specified ranges.
Equipped with ten unique safety-enhanced ECG posts, the ESA620 offers simulation of ECG and performance waveforms so both electrical safety and basic tests on patient monitors can be performed with a single connection. When combined with optional Ansur computer-based software, the ESA620 allows for test procedure automation, the capture of results and comparison to standard limits, printed reports, and total digital data management.
Features:
Specifications:
For full Fluke ESA620 product specifications, please click here: Fluke ESA620
The ESA620 Electrical Safety Analyzer, featuring smart technology to enhance productivity under any standard, represents the next generation in portable electrical safety testers. With selections of three test loads, two protective earth test currents and two insulation test voltages, this versatile device performs all primary electrical safety tests as well as several additional leakage tests for premium standards compliance worldwide.
A convenient 20 A device receptacle broadens the range of equipment that can be tested using the ESA620. Standard 2-wire and optional 4-wire protective earth measurement capabilities offer first-rate time savings, while new DSP technology offers better accuracy of leakage measurements throughout specified ranges.
Equipped with ten unique safety-enhanced ECG posts, the ESA620 offers simulation of ECG and performance waveforms so both electrical safety and basic tests on patient monitors can be performed with a single connection. When combined with optional Ansur computer-based software, the ESA620 allows for test procedure automation, the capture of results and comparison to standard limits, printed reports, and total digital data management.
Features:
- Superior compliance with multiple standards: IEC60601:2005, EN62353, VDE 751, ANSI/AAMI ES1:1993, NFPA-99, AN/NZS 3551, IEC61010
- Three test loads
- Expanded leakage ranges through 10,000 µA
- Dual-lead resistance, leakage, and voltage tests
- AC only, dc only and true-rms leakage readings
- 100 % and 110 % mains voltage for mains on applied part (lead isolation) test
- 200 mA and 25 A ac PE test current
- DSP filter technology for improved accuracy in leakage measurements
- 20 A equipment current
- More applied parts selections
- ECG and performance waveforms
- Intuitive user interface
- Easy-to-use applied parts (ECG) connections
- Insulation posts on applied parts connections
- Five different insulation tests
- Varying insulation test voltage 500 V dc and 250 V dc
- USB connection
- CE, C-TICK and CSA for USA and Canada
- RoHS compliance
- Designed, tested, and built to incomparable Fluke quality standards
Specifications:
Voltage | ||
Range (mains voltage) | 90 V to 132 V ac rms 180 V to 264 V ac rms |
|
Range (accessible voltage) | 0 V to 300 V ac rms | |
Accuracy | ± (2 % of reading +2 LSD) | |
Voltage tests | Mains, accessible, and point-to-point | |
Earth resistance | ||
Two-terminal mode test current/range and accuracy | > 200 mA ac | 0.0 to 2.0 O ± (2 % of reading + 0.015 O) |
10 A to 25 A ac | 0.0 to 0.2 O ± (2 % of reading + 0.015 O) 0.2 to 2.0 O ± (5 % of reading + 0.015 O) |
|
Four-terminal mode test current/range and accuracy | > 200 mA ac | 0.0 to 2.0 O ± (2 % of reading + 0.005 O) |
10 A to 25 A ac | 0.0 to 0.2 O ± (2 % of reading + 0.005 O) 0.2 to 2.0 O ± (5 % of reading + 0.005 O) |
|
Resistance tests | Earth resistance and point-to-point | |
Equipment current | ||
Mode | AC rms | |
Range/accuracy | 0 A to 20 A | ± 5 % of reading ± (2 counts or .2 A, whichever is greater) |
Duty cycle | 15 A to 20 A, 5 min on/5 min off 10 A to 15 A, 7 min on/3 min off 0 A to 10 A continuous |
|
Leakage current | ||
Modes | AC + DC (True-rms) AC only DC only |
|
Patient load selection (input impedance) | AAMI ES1-1993 IEC 60601 IEC 61010 |
|
Crest factor | = 3 | |
Ranges | 0 µA to 199.9 µA 200 µA to 1999 µA 2 mA to 10 mA |
|
Frequency response/accuracy | DC to 1 kHz 1 kHz to 100 kHz 100 kHz to 1 MHz |
± (1 % of reading + 1 µA) ± (2 % of reading + 1 µA) ± (5 % of reading + 1 µA) |
Leakage tests | Earth (ground wire) Chassis (enclosure) Patient (lead to ground) Patient auxiliary (lead to lead) Mains on applied part (lead isolation) Direct equipment Direct applied part Alternative equipment Alternative applied part Accessible Point to point |
|
Mains on applied part test voltage | 110 % of mains at 230 V for IEC 60601 100 % of mains for AAMI at 115 V per AAMI 100 % of mains at 230 V per 62353 |
|
Differential leakage | ||
Ranges | 10 µA to 199 µA 200 µA to 1999 µA 2 mA to 20 mA |
|
Accuracy | ± 10 % of reading ± (2 counts or 20 µA, whichever is greater) | |
Insulation resistance | ||
Ranges/accuracy | 0.5 MO to 20 MO | ± (2 % of reading + 2 counts) |
20 MO to 100 MO | ± (7.5 % of reading + 2 counts) | |
Source test voltage | 500 V dc 250 V dc |
|
Insulation resistance tests | Mains-PE, AP-PE, Mains- PE, Mains-NE (non-earthed accessible conductive part) and AP- NE (non-earthed accessible conductive part) | |
Mamimum load capacitance | 1 µF | |
ECG performance waveforms | ||
Accuracy | ± 2 % ± 5 % for amplitude of 2 Hz square wave only, fixed at 1 mV Lead II configuration |
|
Waveforms | ECG complex (BPM) | 30, 60, 120, 180, and 240 |
Ventricular fibrillation | ||
Square wave (50 % duty cycle) (Hz) | 0.125 and 2 | |
Sine wave (Hz) | 10, 40, 50, 60, and 100 | |
Triangle wave (Hz) | 2 | |
Pulse (63 ms pulse width) | 30 and 60 | |
Power ratings | ||
Mains voltage outlet | 120 V ac | 230 V ac |
Mains voltage inlet power range | 90 to 132 V ac rms | 180 to 264 V ac rms |
Maximum current | 20 A | 16 A |
Hz | 50 or 60 | 50 or 60 |
Physical case | ||
Dimensions (L x W x H) | 31 cm x 23 cm x 10 cm (12.2 in x 9 in x 2.9 in) | |
Weight | 4.7 kg (10.25 lb) | |
Environmental specifications | ||
Operating temperature | 10 °C to 40 °C | |
Storage temperature | -20 °C to 60 °C | |
Operating humidity | 10 % to 90 % non-condensing | |
Altitude | To 2,000 meters |
For full Fluke ESA620 product specifications, please click here: Fluke ESA620