Fluke Networks 990DSL Copper Pro Loop Tester
Condition: Refubished / Calibrated
Warranty: 90 Day Exchange
In its basic configuration, CopperPro offers a broad range of Plain Old Telephone
Services (POTS) troubleshooting, fault location and line qualification capabilities. Its Wideband/TDR option adds high frequency transmission testing and qualification functions for services like ADSL, HDSL, HDSL2, HDSL4, ISDN, T1, E1 and DDS. And the TDR feature of the option adds precise fault location and analysis. The Wideband/TDR option can be added at time of purchase or later at an authorized service center.
At a Glance
- Replaces up to sixteen traditional test sets
- Troubleshoots and qualifies lines for POTS, ADSL and other special services
- Time Domain Reflectometer (TDR) feature allows precision fault location
- Fast, accurate and easy to use
- Compact, rugged and weather resistant
CopperPro's basic configuration is designed for POTS applications including voltage, opens, shorts, balance, RFL, VF noise and loss, terminated and dial-up tests, as well as load coil detection and line monitoring.
The Wideband/TDR option delivers accurate fault location capability in a handheld test set. With it, you can test and compare pairs, store measurements and test for crosstalk between pairs.
The Wideband/TDR option also includes everything you need to qualify and troubleshoot lines for all standard digital services, including HDSL, HDSL2, T1, E1, ISDN BRI, ISDN PRI and DDS. Within seconds, the unique ADSL AutoTest determines whether a pair can provide ADSL service - even predicts upstream and downstream rates and bits per frame.
Versatility with standalone or automation operation
You can identify, locate and repair line faults and qualify loop performance - all at the push of a button. And CopperPro can capture the test results for complete documentation.
CopperPro combines a toolbox approach with programmable Auto-Tests that make testing fast and easy. Results are displayed graphically on its large, bitmapped display that's easy for users to view in all light conditions. In addition, integrated tests combine functions to help the user understand what' causing the problem as well as pinpoint the location.
The result? Better and faster service. Higher productivity - and profitability.
As a standalone tool, CopperPro's handheld design makes it easy to carry and operate wherever testing takes you. CopperPro is easily automated for even greater testing speed and consistency - with documented test results.
Powerful Software enables sixteen test sets in one
You can identify and locate common physical cable faults like shorts, crosses, opens, splits, pair imbalances caused by bad splices and corroded metallic faults on unused pairs.
CopperPro also makes it easy to find the root causes of transmission problems, like excessive noise or signal loss, and helps locate and identify loop treatment devices like range extenders, network interface devices and maintenance termination units.
And, CopperPro makes fast work of qualification for both POTS like Caller ID, ANI and dial up modems, as well as digital broadband services like ADSL (DMT and CAP), T1, E1, DDS, ISDN, HDSL and HDSL2. That includes noise, loss and crosstalk measurements, predicted data rates, and location of impairments like load coils or bridge taps.
CopperPro offers the following sixteen test set capabilities:
1. Digital Multimeter (AC/DC Voltage, Resistance)
2. Opens Meter
3. RFL Meter
4. Noise Meter (VF and WB, Gaussian and Impulse)
5. Time Domain Reflectometer
6. Dial Set
7. Leakage Tester
8. Ammeter (DC)
9. Loss Meter (VF and WB)
10. VF and WB Precision Signal Generator
11. Tracing Tone Generator
12. ANI and CID Tester
13. ADSL Connectivity Tester ラ
14. ADSL and Special Services Pair Qualification Set
15. VF and WB Longitudinal Balance Meter
16. Power Harmonics Analyzer
Ease of Use - do more faster and with less training
Results are displayed graphically on its large, bitmapped display that's easy for you to view in all light conditions. In addition, integrated tests combine functions to help you understand what's causing the problem as well as pinpoint the location.
General Specifications |
||||
|
Display: 320 x 240 pixel graphic LCD with backlight and adjustable contrast LED Indicator: Charging status indicator (side connector panel) Communication Port: RS-232 PC/Printer port (DB-9) |
|||
|
Battery Type (installed): Internal removable NiMH rechargeable battery pack Battery Life: A fully charged battery provides approximately 16 hours of normal use Battery Recharge Time (in tester): 2 to 3 hours for a fully discharged battery pack |
|||
|
Storage Temperature: -40° to 158° F (-40° to 70° C) Humidity Tolerance (operation without condensation): 95% Rain Resistance: IEC60529 IP02, International protection water dripping Vibration: Random, 2 g, 5 Hz to 500 Hz Shock: 1 Meter Drop Test Altitude: 4500 m (15,000 ft) |
|||
|
CE: EN 61326 Emissions and Immunity CLASS A; EN 61010-1 2nd ammendment |
Basic CopperPro |
||||
|
|
|||
|
|
|||
|
|
|||
|
100 ohms to 1000 kohms (0.2% ± 0.10 ohm accuracy) 4 kohms to 999 Mohms (3% accuracy) |
|||
|
|
|||
|
3 to 50 kft (3% accuracy) 50 to 80 kft (5% accuracy) |
|||
|
|
|||
|
Loop Resistance: 0 to 4000 ohms Resistance to Fault (@ Rf = 100 kohms): 0 to 100 ohms (0.1% RTS ± 0.10 ohm); 100 ohms to 4 kohm (0.3% RTS ± 0.10 ohm) |
|||
|
|
|||
|
Range: > 15Vp-p (10% accuracy) |
|||
|
Filters: C, CN, 3k, 15k, Psophometric Metallic Noise: 0 to 10 dBrn (± 2 dB accuracy); 10 to 100 dBrn (± 1 dB accuracy) Power Influence: 40 to 120 dBrn (± 2 dB accuracy) |
|||
|
Frequency: 100 Hz to 20 kHz (0.1% ± 2 Hz accuracy) |
|||
|
Impedance: 600 ohms (1% accuracy) Filters: C, Psophometric |
|||
|
Amplitude (settable) Range: -20 to 3 dBm Amplitude Accuracy: ± 0.5 dB (1 dB increments) Impedance: 600 ohms, 900 ohms (1% accuracy) |
CopperPro Wideband Option |
||||
|
Filters: E, F, G, None Frequency: 10 kHz to 1200 kHz (0.1% ± 508 Hz accuracy) Amplitude: -50 to 3 dBm (± 1 dB @ 135 ohms); -90 to -50 dBm (± 3 dB @ 135 ohms) |
|||
|
Frequency: 10 kHz to 1200 kHz (0.1% ± 508 Hz accuracy) Magnitude: 0 to 50 dB (± 1 dB accuracy); 50 to 70 dB (± 2 dB accuracy) |
|||
|
Impedance: 100 ohms, 135 ohms (1% accuracy) Filters: E, F, G, None |
|||
|
Amplitude (fixed): 0.0 dBm (± 0.5 dB accuracy) Impedance: 100 ohms, 135 ohms (1% accuracy) |
|||
|
Filters: E, F, G, None Test Time: 1 to 1440 Minutes (1% accuracy) Impulse Counter: 0 to 9999 Counter Threshold: -50 to 0 dBm (± 1 dB accuracy) |
|||
|
ADSL Standard: ANSI, Full, G, Lite |
|||
|
Range: 0 to 8192 kb/s Downstream Rate Accuracy: ± 96 kb/s (3 units of resolution) Upstream Rate Range: 0 to 1024 kb/s Upstream Rate Accuracy: ± 64 kb/s (2 units of resolution) |
CopperPro TDR Option |
||||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
Accuracy: 1% ± Vop Uncertainty |
|||
|
Accuracy: 2 dB |
|||
|
|
|||
|
|
|||
|
|
For full Fluke Networks 990 DSL product specifications, please click here: FLuke Networks 990DSL
Fluke Networks 990DSL CopperPro Loop Tester With Options TDR, WB & EXP Enabled
The Wideband/TDR option also includes everything you need to qualify and troubleshoot lines for all standard digital services.
Includes Carrying Case & Accessories As Listed
Fluke Networks 990DSL 990-DSL Copper Pro Tester Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 13100
- Fluke Networks 990DSL CopperPro Loop Tester (BC# 13100) W/ Options:
- WideBand
- TDR
- EXP
- Test Leads Set
- 990DSL Quick Start Guide
- Fluke Networks Gauge
- AC Adapter/Charger
- Power Cord
- RS232 PC Interface Cable
- Hard Copy User Manual
- Carrying Case (G)